ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stopdown Duration_min Frontend Phantom Phantom thickness
  105   Sun Aug 25 06:45:12 2024 tb-crewPiggy test46RD50-MPW4800 MeVLow Flux LowProtonUnknown25.08.2024 06:44:3325.08.2024 06:45:391Normal  
automatic log for run 46
Comment:
first tests, trying to get beam right beam
  103   Sun Aug 25 06:42:38 2024 tb-crewPiggy test45RD50-MPW4800 MeVLow Flux LowProtonUnknown25.08.2024 06:40:5225.08.2024 06:43:042Normal  
automatic log for run 45
Comment:
  102   Sun Aug 25 06:34:56 2024 tb-crewPiggy test44RD50-MPW4800 MeVLow Flux LowProtonUnknown25.08.2024 06:35:1325.08.2024 06:35:230Normal  
automatic log for run 44
Comment:
  197   Sat Dec 14 15:39:11 2024 Felix Ulrich-Purplastic mouse radiography59TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood23:3323:4613 plastic mouse 

pos x=-175, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  90   Sun Jun 9 00:08:07 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser19TOF-Cal GSI194.3 MeVLow Flux HighProtonGood23:2023:30    

5 cm plastic water (in isocentre)
3.7 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 795 kHz on LGAD

WET measurement

  196   Sat Dec 14 15:37:48 2024 Felix Ulrich-Purplastic mouse radiography58TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood23:1723:3013 plastic mouse 

pos x=-175, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  89   Sun Jun 9 00:07:17 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser18TOF-Cal GSI145.4 MeVLow Flux HighProtonGood23:0423:20    

4 cm plastic water (in isocentre)
2 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 500 kHz on LGAD

WET measurement

  195   Sat Dec 14 15:37:26 2024 Felix Ulrich-Purplastic mouse radiography57TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood23:0223:1614 plastic mouse 

pos x=-100, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  88   Sun Jun 9 00:06:01 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser17TOF-Cal GSI194.3 MeVLow Flux HighProtonGood22:5323:04    

4 cm plastic water (in isocentre)
3.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 900 kHz on LGAD

WET measurement

  194   Sat Dec 14 15:36:37 2024 Felix Ulrich-Purplastic mouse radiography56TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood22:4623:0014 plastic mouse 

pos x=-25, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  87   Sun Jun 9 00:05:11 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser (wrong energy)16TOF-Cal GSI194.3 MeVLow Flux HighProtonCrap22:5022:52    

wrong energy don't use

  86   Sun Jun 9 00:04:23 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser15TOF-Cal GSI145.4 MeVLow Flux HighProtonGood22:3422:50    

3 cm plastic water (in isocentre)
2.6 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 400 kHz on LGAD

WET measurement

  193   Sat Dec 14 15:35:56 2024 Felix Ulrich-Purplastic mouse radiography55TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood22:1222:4533 plastic mouse 

pos x=25, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  84   Sat Jun 8 22:12:06 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser13TOF-Cal GSI145.4 MeVLow Flux HighProtonGood22:0522:34    

2cm plastic water (in isocentre)
3.2 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 600 kHz on LGAD

WET measurement

  192   Sat Dec 14 15:34:50 2024 Felix Ulrich-Purplastic mouse radiography54TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood21:5822:1022 plastic mouse 

pos x=100, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  83   Sat Jun 8 21:54:59 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser12TOF-Cal GSI194.3 MeVLow Flux HighProtonGood21:5322:05    

2cm plastic water (in isocentre)
5 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1.2 MHz on LGAD

WET measurement

  85   Sat Jun 8 22:38:41 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser14TOF-Cal GSI194.3 MeVLow Flux HighProtonGood22:1922.34    

3 cm plastic water (in isocentre)
4.3 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1MHz on LGAD

WET measurement

  191   Sat Dec 14 15:33:35 2024 Felix Ulrich-Purplastic mouse radiography53TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood21:3321:5724 plastic mouse 

run 52 was crap

pos x=175, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  82   Sat Jun 8 21:43:26 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser11TOF-Cal GSI145.4 MeVLow Flux HighProtonGood21:3921:48    

1cm plastic water (in isocentre)
4 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 700 kHz on LGAD

WET measurement

  81   Sat Jun 8 21:42:13 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser10TOF-Cal GSI194.3 MeVLow Flux HighProtonGood21:2721:39    

1cm plastic water (in isocentre)
6 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1.5 MHz on LGAD

WET measurement

ELOG V3.1.5-fc6679b