ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Datadown t-Start t-Stop Duration_min Frontend
  95   Sun Jun 9 01:26:56 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen24TOF-Cal GSI145.4 MeVLow Flux HighProtonGood01:0201:14  

2 cm dense bone (in isocentre)
2.1 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 315 kHz on LGAD

WET measurement

  96   Sun Jun 9 01:27:38 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen25TOF-Cal GSI194.3 MeVLow Flux HighProtonGood01:1601:30  

3 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 600 kHz on LGAD

WET measurement

  97   Sun Jun 9 01:32:51 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen26TOF-Cal GSI145.4 MeVLow Flux HighProtonGood01:3001:45  

3 cm dense bone (in isocentre)
1.7 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 230 kHz on LGAD

WET measurement

  98   Sun Jun 9 01:48:51 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen27TOF-Cal GSI194.3 MeVLow Flux HighProtonGood01:4801:59  

4 cm dense bone (in isocentre)
2 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 470 kHz on LGAD

WET measurement

  100   Sun Jun 9 02:02:16 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen28TOF-Cal GSI145.4 MeVLow Flux HighProtonGood02:0002:14  

4 cm dense bone (in isocentre)
1.4 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 175 kHz on LGAD

WET measurement

  101   Sun Jun 9 02:18:55 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen29TOF-Cal GSI194.3 MeVLow Flux HighProtonGood02:18   

5 cm dense bone (in isocentre)
1.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 350 kHz on LGAD

WET measurement

  10   Sat Mar 30 07:59:55 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonCrap   Normal
currently no beam
  15   Sat Mar 30 08:40:10 2024 bp, ci, hhRD50-MPW41008RD50-MPW4800 MeVLow Flux Very LowProtonCrap30.03.2024 08:37:0330.03.2024 08:42:375Normal
automatic log for run 1008
Comment:
waiting for beam
  16   Sat Mar 30 08:56:25 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonCrap   Normal
waiting for beam
Performing MTS restart
  17   Sat Mar 30 09:03:54 2024 bp, ci, hhRD50-MPW41009RD50-MPW4800 MeVLow Flux Very LowProtonCrap30.03.2024 08:43:2230.03.2024 09:06:2022Normal
automatic log for run 1009
Comment:
waiting for beam
Performing MTS restart
  18   Sat Mar 30 09:15:13 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonCrap   Normal
moved entire setup a bit in order too better focus beam on MPW4 (hopefully)
  19   Sat Mar 30 09:25:05 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonCrap   Normal
bea is back Big grin
  20   Sat Mar 30 09:27:33 2024 bp, ci, hhRD50-MPW41010RD50-MPW4800 MeVLow Flux Very LowProtonCrap30.03.2024 09:23:4230.03.2024 09:29:596Normal
automatic log for run 1010
Comment:
  31   Sat Mar 30 10:23:06 2024 bp, ci, hhRD50-MPW41017RD50-MPW4800 MeVLow Flux LowProtonCrap30.03.2024 10:25:0930.03.2024 10:25:330Normal
automatic log for run 1017
Comment:
changed rate to low again, too much "noise"
also moved table down and a bit to the left

no HV, is crap
  32   Sat Mar 30 10:25:55 2024 bp, ci, hhRD50-MPW41018RD50-MPW4800 MeVLow Flux LowProtonCrap30.03.2024 10:26:1730.03.2024 10:28:212Normal
automatic log for run 1018
Comment:
  33   Sat Mar 30 10:27:56 2024 bp, ci, hhRD50-MPW41019RD50-MPW4800 MeVLow Flux LowProtonCrap30.03.2024 10:28:2830.03.2024 10:30:221Normal
automatic log for run 1019
Comment:
  64   Sat Mar 30 18:59:16 2024 hh, mb, ps1st tests1047TJ-Monopix2800 MeVLow Flux LowProtonCrap30.03.2024 19:00:1130.03.2024 19:01:431HV
automatic log for run 1047
Comment:
Test if we get beam, MAUS has problems
  87   Sun Jun 9 00:05:11 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser (wrong energy)16TOF-Cal GSI194.3 MeVLow Flux HighProtonCrap22:5022:52  

wrong energy don't use

  1   Sat Mar 30 06:34:39 2024 Bernhard PilslAnd a new testbeam starts :D          
  11   Sat Mar 30 08:05:59 2024 Christian IrmlerRD50-MPW4999         

Tracker calibration run: mpw4-tj-monopix2_00-000999.xml
Generated global xml file for MPW4 shift: mpw4-tj-monopix2_TLU_00-000999.xml 

Previous local runs and xml files (mpw4-tj-monopix2_00-000212.xml) are unusable, because sensor L5.1.1.0 had a loose cotact and thus low gain.
Fixed by disconnecting and reconnecting.