Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2024, Page 3 of 11  Not logged in ELOG logo
Entry  Sat Dec 14 15:19:57 2024, Felix Ulrich-Pur, WET measurement slabs, 41, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 17:32, 17:44, 12, , Dense Bone Slabs, 2cm 

2cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset

4MHz Ramon 600 kHz TRB

Entry  Sat Dec 14 15:20:52 2024, Felix Ulrich-Pur, WET measurement slabs, 42, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 17:48, 18:00, 12, , Dense Bone Slabs, 2cm 

2cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset

2.5MHz Ramon 250 kHz TRB

Entry  Sat Dec 14 15:21:44 2024, Felix Ulrich-Pur, WET measurement slabs, 43, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 18:04, 18:18, 14, , Dense Bone Slabs, 3cm 

3cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset

4MHz Ramon 1MHz TRB

Entry  Sat Dec 14 15:23:21 2024, Felix Ulrich-Pur, WET measurement slabs, 44, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 18:19, 18:33, 14, , Dense Bone Slabs, 2cm 

3cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset

4MHz Ramon 200kHz TRB

Entry  Sat Dec 14 15:24:22 2024, Felix Ulrich-Pur, WET measurement slabs, 45, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 18:37, 18:51, 14, , Dense Bone Slabs, 4cm 

4cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset

3MHz Ramon 800kHz TRB

Entry  Sat Dec 14 15:25:12 2024, Felix Ulrich-Pur, WET measurement slabs, 46, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 18:55, 19:11, 16, , Dense Bone Slabs, 4cm 

4cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset

2MHz Ramon 120kHz TRB

Entry  Sat Dec 14 15:26:18 2024, Felix Ulrich-Pur, WET measurement slabs, 47, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 19:16, 19:29, 13, , Dense Bone Slabs, 5cm 

5cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset

3MHz Ramon 300kHz TRB

Entry  Sat Dec 14 15:27:08 2024, Felix Ulrich-Pur, WET measurement slabs, 48, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 19:30, 19:50, 20, , Dense Bone Slabs, 5cm 

5cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset

1.5MHz Ramon

Wave crashes if 1 TDC disappears in dog d, DABC is still running

Entry  Sat Mar 30 06:34:39 2024, Bernhard Pilsl, And a new testbeam starts :D, , , , , , , , , , , ,  
 
Entry  Sat Mar 30 06:53:31 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, , , , Normal, ,  mpw4.inidetectors.geo
about to start

geo and eudaq ini attached
Entry  Sat Mar 30 06:54:51 2024, bp, ci, hh, RD50-MPW4, 1000, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 30.03.2024 06:56:23, 30.03.2024 06:57:18, 0, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1000
Comment:
1st test runs
Entry  Sat Mar 30 07:00:10 2024, bp, ci, hh, RD50-MPW4, 1001, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 30.03.2024 06:58:03, 30.03.2024 07:02:36, 4, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1001
Comment:
1st test runs
Entry  Sat Mar 30 07:09:36 2024, bp, ci, hh, RD50-MPW4, 1002, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 30.03.2024 07:11:15, 30.03.2024 07:12:03, 0, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1002
Comment:
1st test runs
Entry  Sat Mar 30 07:11:30 2024, bp, ci, hh, RD50-MPW4, 1003, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 30.03.2024 07:12:19, 30.03.2024 07:13:57, 1, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1003
Comment:
1st test runs
Entry  Sat Mar 30 07:22:49 2024, bp, ci, hh, RD50-MPW4, 1004, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 30.03.2024 07:14:51, 30.03.2024 07:25:16, 10, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1004
Comment:
1st test runs
Entry  Sat Mar 30 07:44:15 2024, bp, ci, hh, RD50-MPW4, 1005, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 30.03.2024 07:25:51, 30.03.2024 07:46:41, 20, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1005
Comment:
beautifully correlated Big grin
Entry  Sat Mar 30 07:59:41 2024, bp, ci, hh, RD50-MPW4, 1006, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Good, 30.03.2024 07:46:50, 30.03.2024 08:02:08, 15, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1006
Comment:
beautifully correlated Big grin
Entry  Sat Mar 30 07:59:55 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, , , , Normal, ,  
currently no beam
Entry  Sat Mar 30 08:05:59 2024, Christian Irmler, RD50-MPW4, 999, , , , , , , , , , ,  

Tracker calibration run: mpw4-tj-monopix2_00-000999.xml
Generated global xml file for MPW4 shift: mpw4-tj-monopix2_TLU_00-000999.xml 

Previous local runs and xml files (mpw4-tj-monopix2_00-000212.xml) are unusable, because sensor L5.1.1.0 had a loose cotact and thus low gain.
Fixed by disconnecting and reconnecting.

Entry  Sat Mar 30 08:21:04 2024, bp, ci, hh, RD50-MPW4, 1007, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Good, 30.03.2024 08:02:46, 30.03.2024 08:23:30, 20, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1007
Comment:
waiting for eam
ELOG V3.1.5-fc6679b