ID |
Date |
Author |
Subject |
Run Number |
DUT |
Beam Energy |
Rate Setting |
Particle Type |
Data |
t-Start |
t-Stop |
Duration_min |
Frontend |
Phantom |
Phantom thickness |
Text |
|
135
|
Sun Aug 25 12:23:44 2024 |
tb-crew | only base | 69 | RD50-MPW4 | 175.3 MeV | Low Flux Very Low | Proton | Unknown | 25.08.2024 12:04:32 | 25.08.2024 12:24:10 | 19 | Normal | | | automatic log for run 69
Comment:
E-scan |
|
207
|
Sat Dec 14 15:45:05 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 69 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 02:07 | 02:25 | 18 | | plastic mouse | | pos x=25, posy=75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
134
|
Sun Aug 25 12:00:00 2024 |
tb-crew | only base | 68 | RD50-MPW4 | 252.7 MeV | Low Flux Very Low | Proton | Unknown | 25.08.2024 11:37:41 | 25.08.2024 12:00:27 | 22 | Normal | | | automatic log for run 68
Comment:
E-scan |
|
206
|
Sat Dec 14 15:43:45 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 68 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 01:51 | 02:07 | 16 | | plastic mouse | | pos x=100, posy=75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
133
|
Sun Aug 25 11:35:21 2024 |
tb-crew | only base | 67 | RD50-MPW4 | 252.7 MeV | Low Flux Very Low | Proton | Unknown | 25.08.2024 11:35:33 | 25.08.2024 11:35:48 | 0 | Normal | | | automatic log for run 67
Comment:
E-scan |
|
205
|
Sat Dec 14 15:43:01 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 67 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 01:35 | 01:51 | 16 | | plastic mouse | | pos x=175, posy=75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
131
|
Sun Aug 25 11:31:49 2024 |
tb-crew | only base | 66 | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Unknown | 25.08.2024 11:21:06 | 25.08.2024 11:32:16 | 11 | Normal | | | automatic log for run 66
Comment:
experimental DAC settings |
|
204
|
Sat Dec 14 15:42:32 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 66 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 01:21 | 01:34 | 13 | | plastic mouse | | pos x=250, posy=75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
130
|
Sun Aug 25 11:19:53 2024 |
tb-crew | only base | 65 | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Unknown | 25.08.2024 11:17:22 | 25.08.2024 11:20:20 | 2 | Normal | | | automatic log for run 65
Comment:
experimental DAC settings |
|
203
|
Sat Dec 14 15:42:01 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 65 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 01:08 | 01:20 | 12 | | plastic mouse | | pos x=250, posy=-75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
129
|
Sun Aug 25 11:16:09 2024 |
tb-crew | only base | 64 | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Unknown | 25.08.2024 11:14:19 | 25.08.2024 11:16:36 | 2 | Normal | | | automatic log for run 64
Comment:
experimental DAC settings |
|
202
|
Sat Dec 14 15:41:43 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 64 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 00:54 | 01:08 | 17 | | plastic mouse | | pos x=175, posy=-75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
128
|
Sun Aug 25 11:09:44 2024 |
tb-crew | only base | 63 | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Unknown | 25.08.2024 10:59:42 | 25.08.2024 11:10:11 | 10 | Normal | | | automatic log for run 63
Comment:
vnfb = 60 |
|
201
|
Sat Dec 14 15:41:19 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 63 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 00:37 | 00:54 | 17 | | plastic mouse | | pos x=100, posy=-75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
127
|
Sun Aug 25 10:58:26 2024 |
tb-crew | only base | 62 | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Unknown | 25.08.2024 10:48:27 | 25.08.2024 10:58:53 | 10 | Normal | | | automatic log for run 62
Comment:
vnfb = 10 |
|
200
|
Sat Dec 14 15:40:45 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 62 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 00:22 | 00:37 | 15 | | plastic mouse | | pos x=25, posy=-75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
126
|
Sun Aug 25 10:44:10 2024 |
tb-crew | only base | 61 | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Unknown | 25.08.2024 10:28:18 | 25.08.2024 10:44:37 | 16 | Normal | | | automatic log for run 61
Comment:
normal statistic run |
|
199
|
Sat Dec 14 15:40:09 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 61 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 00:09 | 00:22 | 13 | | plastic mouse | | pos x=-25, posy=-75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
125
|
Sun Aug 25 10:26:57 2024 |
tb-crew | only base | 60 | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Unknown | 25.08.2024 10:12:04 | 25.08.2024 10:27:24 | 15 | Normal | | | automatic log for run 60
Comment:
normal statistic run; !!! en_tb_mode was |
|
198
|
Sat Dec 14 15:39:42 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 60 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 23:50 | 00:08 | 18 | | plastic mouse | | pos x=-100, posy=-75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|