Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2024, Page 1 of 11  Not logged in ELOG logo
ID Date Author Subject Run Numberdown DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min Frontend Phantom Phantom thickness
  11   Sat Mar 30 08:05:59 2024 Christian IrmlerRD50-MPW4999           

Tracker calibration run: mpw4-tj-monopix2_00-000999.xml
Generated global xml file for MPW4 shift: mpw4-tj-monopix2_TLU_00-000999.xml 

Previous local runs and xml files (mpw4-tj-monopix2_00-000212.xml) are unusable, because sensor L5.1.1.0 had a loose cotact and thus low gain.
Fixed by disconnecting and reconnecting.

  80   Sat Jun 8 21:41:04 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve9TOF-Cal GSI62.4 MeVLow Flux HighProtonGood20:5521:21    

changed back to high due to beamsize vs LGAD size factor
650 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 230kHz on LGAD

TOF Calibration Curve

  148   Sat Dec 14 12:56:38 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon9RaMon177.8 MeV/uLow Flux HighHeliumGood06:4006:411   

Mean rate per spill~ 4.5e6 p/s (online estimation without proper analysis)

  218   Sat Dec 14 15:50:19 2024 Felix Ulrich-PurLGAD+Diamond test with clinical carbon beam80TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon402MeV/u CarbonGood05:1505:5035   

Carbon Deg10 (clinical rate)

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  79   Sat Jun 8 20:11:00 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve8TOF-Cal GSI83 MeVLow Flux MediumProtonGood19:4220:51    

300 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 35kHz on LGAD

TOF Calibration Curve

  147   Sat Dec 14 12:56:05 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon8RaMon205.2 MeV/uLow Flux HighHeliumGood06:3906:401   

Mean rate per spill~ 5e6 p/s (online estimation without proper analysis)

  217   Sat Dec 14 15:49:58 2024 Felix Ulrich-Purplastic mouse radiography79TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood04:5105:0514 plastic mouse 

pos x=250, posy=-175

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  216   Sat Dec 14 15:49:32 2024 Felix Ulrich-Purplastic mouse radiography78TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood04:3604:5014 plastic mouse 

pos x=175, posy=-175

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  215   Sat Dec 14 15:49:12 2024 Felix Ulrich-Purplastic mouse radiography77TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood04:2204:3614 plastic mouse 

pos x=100, posy=-175

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  214   Sat Dec 14 15:48:49 2024 Felix Ulrich-Purplastic mouse radiography76TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood04:0604:2115 plastic mouse 

pos x=25, posy=-175

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  213   Sat Dec 14 15:48:26 2024 Felix Ulrich-Purplastic mouse radiography75TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood03:5204:0513 plastic mouse 

pos x=-25, posy=-175

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  212   Sat Dec 14 15:47:59 2024 Felix Ulrich-Purplastic mouse radiography74TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood03:3503:5116 plastic mouse 

pos x=-100, posy=-175

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  211   Sat Dec 14 15:47:29 2024 Felix Ulrich-Purplastic mouse radiography73TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood03:2003:5525 plastic mouse 

pos x=-175, posy=-175

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  210   Sat Dec 14 15:46:54 2024 Felix Ulrich-Purplastic mouse radiography72TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood03:0303:1916 plastic mouse 

pos x=-175, posy=75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  137   Sun Aug 25 12:51:10 2024 tb-crewonly base71RD50-MPW462.4 MeVLow Flux Very LowProtonUnknown25.08.2024 12:40:4125.08.2024 12:51:3710Normal  
automatic log for run 71
Comment:
E-scan
  209   Sat Dec 14 15:46:16 2024 Felix Ulrich-Purplastic mouse radiography71TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood02:4603:0317 plastic mouse 

pos x=-100, posy=75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  136   Sun Aug 25 12:39:45 2024 tb-crewonly base70RD50-MPW4100.4 MeVLow Flux Very LowProtonUnknown25.08.2024 12:24:3625.08.2024 12:40:1215Normal  
automatic log for run 70
Comment:
E-scan
  208   Sat Dec 14 15:45:36 2024 Felix Ulrich-Purplastic mouse radiography70TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood02:2502:4520 plastic mouse 

pos x=-25, posy=75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

beam was shortly off at 02:30

  78   Sat Jun 8 20:09:25 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve7TOF-Cal GSI100.4 MeVLow Flux MediumProtonGood19:0019:42    

300 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 65kHz on LGAD

TOF Calibration Curve

  146   Sat Dec 14 12:55:41 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon7RaMon63.3 MeV/uLow Flux MediumHeliumGood06:3506:361   

Mean rate per spill~ 2-5E5 p/s (online estimation without proper analysis)

ELOG V3.1.5-fc6679b