Sat Mar 30 08:56:25 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, , , , Normal, ,
|
waiting for beam
Performing MTS restart |
Sat Mar 30 09:03:54 2024, bp, ci, hh, RD50-MPW4, 1009, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, 30.03.2024 08:43:22, 30.03.2024 09:06:20, 22, Normal, ,
|
automatic log for run 1009
Comment:
waiting for beam
Performing MTS restart |
Sat Mar 30 09:15:13 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, , , , Normal, ,
|
moved entire setup a bit in order too better focus beam on MPW4 (hopefully) |
Sat Mar 30 09:25:05 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, , , , Normal, ,
|
bea is back |
Sat Mar 30 09:27:33 2024, bp, ci, hh, RD50-MPW4, 1010, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, 30.03.2024 09:23:42, 30.03.2024 09:29:59, 6, Normal, ,
|
automatic log for run 1010
Comment: |
Sat Mar 30 10:23:06 2024, bp, ci, hh, RD50-MPW4, 1017, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Crap, 30.03.2024 10:25:09, 30.03.2024 10:25:33, 0, Normal, ,
|
automatic log for run 1017
Comment:
changed rate to low again, too much "noise"
also moved table down and a bit to the left
no HV, is crap |
Sat Mar 30 10:25:55 2024, bp, ci, hh, RD50-MPW4, 1018, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Crap, 30.03.2024 10:26:17, 30.03.2024 10:28:21, 2, Normal, ,
|
automatic log for run 1018
Comment: |
Sat Mar 30 10:27:56 2024, bp, ci, hh, RD50-MPW4, 1019, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Crap, 30.03.2024 10:28:28, 30.03.2024 10:30:22, 1, Normal, ,
|
automatic log for run 1019
Comment: |
Sat Mar 30 18:59:16 2024, hh, mb, ps, 1st tests, 1047, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Crap, 30.03.2024 19:00:11, 30.03.2024 19:01:43, 1, HV, ,
|
automatic log for run 1047
Comment:
Test if we get beam, MAUS has problems |
Sun Jun 9 00:05:11 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Wasser (wrong energy), 16, TOF-Cal GSI, 194.3 MeV, Low Flux High, Proton, Crap, 22:50, 22:52, , , ,
|
wrong energy don't use |
Sun Aug 25 10:06:51 2024, tb-crew, only base, 59, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, 25.08.2024 10:05:01, 25.08.2024 10:07:18, 2, Normal, ,
|
automatic log for run 59
Comment:
reducing base threshold |
Sat Dec 14 13:02:29 2024, Felix Ulrich-Pur, Shift 23.11.24 low flux Carbon test with RaMon (did not work), 15, RaMon, , Low Flux High, Carbon, Crap, 06:55, 07:01, 6, , ,
|
Low flux carbon did not work
1µs EFE, 30s Extraction, Deg100
we tried different energies (402.MeV/u)-> 120 MeV/u, but unfortunately we did not get any beam |
Sat Dec 14 13:04:57 2024, Felix Ulrich-Pur, Shift 23.11.24 low flux Carbon test with RaMon (did not work), 16, RaMon, , Low Flux High, Carbon, Crap, 07:02, 07:20, 18, , ,
|
Low flux carbon did not work
5µs EFE, 10s Extraction, Deg100
we tried different energies (402.MeV/u)-> 238 MeV/u, but unfortunately we did not get any beam |
Sat Mar 30 06:34:39 2024, Bernhard Pilsl, And a new testbeam starts :D, , , , , , , , , , , ,
|
|
Sat Mar 30 08:05:59 2024, Christian Irmler, RD50-MPW4, 999, , , , , , , , , , ,
|
Tracker calibration run: mpw4-tj-monopix2_00-000999.xml
Generated global xml file for MPW4 shift: mpw4-tj-monopix2_TLU_00-000999.xml
Previous local runs and xml files (mpw4-tj-monopix2_00-000212.xml) are unusable, because sensor L5.1.1.0 had a loose cotact and thus low gain.
Fixed by disconnecting and reconnecting. |
Sun Aug 25 10:02:35 2024, RD50 Generic User, init_geo_file, , , , , , , , , , , ,
|
position of duts needs to be switched |
Mon Aug 26 09:18:25 2024, RD50 Generic User, geo, , , , , , , , , , , ,
|
new geo file with adjusted dut position |
|