Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2024, Page 11 of 11  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min Frontend Phantom Phantom thicknessdown
  202   Sat Dec 14 15:41:43 2024 Felix Ulrich-Purplastic mouse radiography64TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:5401:0817 plastic mouse 

pos x=175, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  203   Sat Dec 14 15:42:01 2024 Felix Ulrich-Purplastic mouse radiography65TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood01:0801:2012 plastic mouse 

pos x=250, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  204   Sat Dec 14 15:42:32 2024 Felix Ulrich-Purplastic mouse radiography66TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood01:2101:3413 plastic mouse 

pos x=250, posy=75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  205   Sat Dec 14 15:43:01 2024 Felix Ulrich-Purplastic mouse radiography67TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood01:3501:5116 plastic mouse 

pos x=175, posy=75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  206   Sat Dec 14 15:43:45 2024 Felix Ulrich-Purplastic mouse radiography68TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood01:5102:0716 plastic mouse 

pos x=100, posy=75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  207   Sat Dec 14 15:45:05 2024 Felix Ulrich-Purplastic mouse radiography69TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood02:0702:2518 plastic mouse 

pos x=25, posy=75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  208   Sat Dec 14 15:45:36 2024 Felix Ulrich-Purplastic mouse radiography70TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood02:2502:4520 plastic mouse 

pos x=-25, posy=75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

beam was shortly off at 02:30

  209   Sat Dec 14 15:46:16 2024 Felix Ulrich-Purplastic mouse radiography71TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood02:4603:0317 plastic mouse 

pos x=-100, posy=75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  210   Sat Dec 14 15:46:54 2024 Felix Ulrich-Purplastic mouse radiography72TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood03:0303:1916 plastic mouse 

pos x=-175, posy=75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  211   Sat Dec 14 15:47:29 2024 Felix Ulrich-Purplastic mouse radiography73TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood03:2003:5525 plastic mouse 

pos x=-175, posy=-175

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  212   Sat Dec 14 15:47:59 2024 Felix Ulrich-Purplastic mouse radiography74TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood03:3503:5116 plastic mouse 

pos x=-100, posy=-175

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  213   Sat Dec 14 15:48:26 2024 Felix Ulrich-Purplastic mouse radiography75TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood03:5204:0513 plastic mouse 

pos x=-25, posy=-175

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  214   Sat Dec 14 15:48:49 2024 Felix Ulrich-Purplastic mouse radiography76TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood04:0604:2115 plastic mouse 

pos x=25, posy=-175

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  215   Sat Dec 14 15:49:12 2024 Felix Ulrich-Purplastic mouse radiography77TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood04:2204:3614 plastic mouse 

pos x=100, posy=-175

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  216   Sat Dec 14 15:49:32 2024 Felix Ulrich-Purplastic mouse radiography78TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood04:3604:5014 plastic mouse 

pos x=175, posy=-175

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  217   Sat Dec 14 15:49:58 2024 Felix Ulrich-Purplastic mouse radiography79TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood04:5105:0514 plastic mouse 

pos x=250, posy=-175

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  218   Sat Dec 14 15:50:19 2024 Felix Ulrich-PurLGAD+Diamond test with clinical carbon beam80TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon402MeV/u CarbonGood05:1505:5035   

Carbon Deg10 (clinical rate)

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

ELOG V3.1.5-fc6679b