162
|
Sat Dec 14 13:35:59 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration | 23 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 124.4 MeV/u | Low Flux High | Helium | Good | 11:24 | 11:37 | 13 | | | | TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000
5MHz with Ramon and only 500kHz |
|
163
|
Sat Dec 14 13:37:26 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration | 24 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 73.2 MeV/u | Low Flux High | Helium | Good | 11:42 | 12:00 | 18 | | | | TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000
2MHz with Ramon and only 200kHz |
|
164
|
Sat Dec 14 13:39:15 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration | 25 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 63.3 MeV/u | Low Flux High | Helium | Good | 12:05 | 12:23 | 18 | | | | TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000
380 kHz with Ramon and only 180kHz |
|
165
|
Sat Dec 14 13:40:47 2024 |
Felix Ulrich-Pur | threshold and preamp tests | 26 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 63.3 MeV/u | Low Flux High | Helium | Good | 12:35 | 12:49 | 14 | | | | TRB Setup: 260V bias and 250mA pre-amps,
threshold 10000 (changed threshold)
Diamond: 500mA, threshold 50 |
|
166
|
Sat Dec 14 13:42:52 2024 |
Felix Ulrich-Pur | threshold and preamp tests | 27 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 63.3 MeV/u | Low Flux High | Helium | Good | 12:52 | 13:16 | 24 | | | | TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000 (changed threshold)
Diamond: 900mA, threshold 50 |
|
167
|
Sat Dec 14 13:45:34 2024 |
Felix Ulrich-Pur | threshold and preamp tests | 28 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 63.3 MeV/u | Low Flux High | Helium | Good | 13:20 | 13:32 | 2 | | | | TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000 (changed threshold)
Diamond: 900mA, threshold 1000 |
|
188
|
Sat Dec 14 15:28:46 2024 |
Felix Ulrich-Pur | threshold and preamp tests | 49 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 20:04 | 20:09 | 5 | | | | TRB Setup: 260V bias and 250mA pre-amps,
threshold 10000 (was too high)
Diamond: 900mA, threshold 1000 |
|
189
|
Sat Dec 14 15:30:23 2024 |
Felix Ulrich-Pur | threshold and preamp tests | 50 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 20:19 | 20:35 | 16 | | | | TRB Setup: 260V bias and 250mA pre-amps,
threshold 5000 (looks good, clustersize max
at ~3) |
|
190
|
Sat Dec 14 15:31:32 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 51 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 21:14 | 21:30 | 16 | | plastic mouse | | before run, mouse was aligned with lasers
and shift of beam w.r.t. sensor center was
taken into account |
|
191
|
Sat Dec 14 15:33:35 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 53 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 21:33 | 21:57 | 24 | | plastic mouse | | run 52 was crap
pos x=175, posy=0
TRB Setup: 260V bias and 250mA |
|
192
|
Sat Dec 14 15:34:50 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 54 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 21:58 | 22:10 | 22 | | plastic mouse | | pos x=100, posy=0
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
193
|
Sat Dec 14 15:35:56 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 55 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 22:12 | 22:45 | 33 | | plastic mouse | | pos x=25, posy=0
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
194
|
Sat Dec 14 15:36:37 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 56 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 22:46 | 23:00 | 14 | | plastic mouse | | pos x=-25, posy=0
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
195
|
Sat Dec 14 15:37:26 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 57 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 23:02 | 23:16 | 14 | | plastic mouse | | pos x=-100, posy=0
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
196
|
Sat Dec 14 15:37:48 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 58 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 23:17 | 23:30 | 13 | | plastic mouse | | pos x=-175, posy=0
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
197
|
Sat Dec 14 15:39:11 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 59 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 23:33 | 23:46 | 13 | | plastic mouse | | pos x=-175, posy=-75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
198
|
Sat Dec 14 15:39:42 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 60 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 23:50 | 00:08 | 18 | | plastic mouse | | pos x=-100, posy=-75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
199
|
Sat Dec 14 15:40:09 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 61 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 00:09 | 00:22 | 13 | | plastic mouse | | pos x=-25, posy=-75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
200
|
Sat Dec 14 15:40:45 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 62 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 00:22 | 00:37 | 15 | | plastic mouse | | pos x=25, posy=-75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
201
|
Sat Dec 14 15:41:19 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 63 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 00:37 | 00:54 | 17 | | plastic mouse | | pos x=100, posy=-75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|