ID |
Date |
Author |
Subject |
Run Number |
DUT |
Beam Energy |
Rate Setting |
Particle Type |
Data |
t-Start |
t-Stop |
Duration_min |
Frontend |
Phantom |
Phantom thickness |
Text |
|
186
|
Sat Dec 14 15:26:18 2024 |
Felix Ulrich-Pur | WET measurement slabs | 47 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 19:16 | 19:29 | 13 | | Dense Bone Slabs | 5cm | 5cm dense bone
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
187
|
Sat Dec 14 15:27:08 2024 |
Felix Ulrich-Pur | WET measurement slabs | 48 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 19:30 | 19:50 | 20 | | Dense Bone Slabs | 5cm | 5cm dense bone
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
188
|
Sat Dec 14 15:28:46 2024 |
Felix Ulrich-Pur | threshold and preamp tests | 49 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 20:04 | 20:09 | 5 | | | | TRB Setup: 260V bias and 250mA pre-amps,
threshold 10000 (was too high)
Diamond: 900mA, threshold 1000 |
|
189
|
Sat Dec 14 15:30:23 2024 |
Felix Ulrich-Pur | threshold and preamp tests | 50 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 20:19 | 20:35 | 16 | | | | TRB Setup: 260V bias and 250mA pre-amps,
threshold 5000 (looks good, clustersize max
at ~3) |
|
190
|
Sat Dec 14 15:31:32 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 51 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 21:14 | 21:30 | 16 | | plastic mouse | | before run, mouse was aligned with lasers
and shift of beam w.r.t. sensor center was
taken into account |
|
191
|
Sat Dec 14 15:33:35 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 53 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 21:33 | 21:57 | 24 | | plastic mouse | | run 52 was crap
pos x=175, posy=0
TRB Setup: 260V bias and 250mA |
|
192
|
Sat Dec 14 15:34:50 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 54 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 21:58 | 22:10 | 22 | | plastic mouse | | pos x=100, posy=0
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
193
|
Sat Dec 14 15:35:56 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 55 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 22:12 | 22:45 | 33 | | plastic mouse | | pos x=25, posy=0
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
194
|
Sat Dec 14 15:36:37 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 56 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 22:46 | 23:00 | 14 | | plastic mouse | | pos x=-25, posy=0
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
195
|
Sat Dec 14 15:37:26 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 57 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 23:02 | 23:16 | 14 | | plastic mouse | | pos x=-100, posy=0
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
196
|
Sat Dec 14 15:37:48 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 58 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 23:17 | 23:30 | 13 | | plastic mouse | | pos x=-175, posy=0
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
197
|
Sat Dec 14 15:39:11 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 59 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 23:33 | 23:46 | 13 | | plastic mouse | | pos x=-175, posy=-75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
198
|
Sat Dec 14 15:39:42 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 60 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 23:50 | 00:08 | 18 | | plastic mouse | | pos x=-100, posy=-75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
199
|
Sat Dec 14 15:40:09 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 61 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 00:09 | 00:22 | 13 | | plastic mouse | | pos x=-25, posy=-75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
200
|
Sat Dec 14 15:40:45 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 62 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 00:22 | 00:37 | 15 | | plastic mouse | | pos x=25, posy=-75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
201
|
Sat Dec 14 15:41:19 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 63 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 00:37 | 00:54 | 17 | | plastic mouse | | pos x=100, posy=-75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
202
|
Sat Dec 14 15:41:43 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 64 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 00:54 | 01:08 | 17 | | plastic mouse | | pos x=175, posy=-75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
203
|
Sat Dec 14 15:42:01 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 65 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 01:08 | 01:20 | 12 | | plastic mouse | | pos x=250, posy=-75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
204
|
Sat Dec 14 15:42:32 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 66 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 01:21 | 01:34 | 13 | | plastic mouse | | pos x=250, posy=75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
205
|
Sat Dec 14 15:43:01 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 67 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 01:35 | 01:51 | 16 | | plastic mouse | | pos x=175, posy=75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|