ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Data t-Startdown t-Stop Duration_min Frontend Phantom Phantom thickness
  204   Sat Dec 14 15:42:32 2024 Felix Ulrich-Purplastic mouse radiography66TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood01:2101:3413 plastic mouse 

pos x=250, posy=75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  96   Sun Jun 9 01:27:38 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen25TOF-Cal GSI194.3 MeVLow Flux HighProtonGood01:1601:30    

3 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 600 kHz on LGAD

WET measurement

  203   Sat Dec 14 15:42:01 2024 Felix Ulrich-Purplastic mouse radiography65TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood01:0801:2012 plastic mouse 

pos x=250, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  95   Sun Jun 9 01:26:56 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen24TOF-Cal GSI145.4 MeVLow Flux HighProtonGood01:0201:14    

2 cm dense bone (in isocentre)
2.1 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 315 kHz on LGAD

WET measurement

  202   Sat Dec 14 15:41:43 2024 Felix Ulrich-Purplastic mouse radiography64TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:5401:0817 plastic mouse 

pos x=175, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  201   Sat Dec 14 15:41:19 2024 Felix Ulrich-Purplastic mouse radiography63TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:3700:5417 plastic mouse 

pos x=100, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  94   Sun Jun 9 01:25:26 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen23TOF-Cal GSI194.3 MeVLow Flux HighProtonGood00:3001:02    

2 cm dense bone (in isocentre)
- Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1 MHz on LGAD

interlock at 00:31 till 00:50 --> 19min break

WET measurement

  200   Sat Dec 14 15:40:45 2024 Felix Ulrich-Purplastic mouse radiography62TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:2200:3715 plastic mouse 

pos x=25, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  93   Sun Jun 9 01:22:48 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen22TOF-Cal GSI145.4 MeVLow Flux HighProtonGood00:1400:23    

1 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 600 kHz on LGAD

WET measurement

  199   Sat Dec 14 15:40:09 2024 Felix Ulrich-Purplastic mouse radiography61TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:0900:2213 plastic mouse 

pos x=-25, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  92   Sun Jun 9 00:12:41 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen21TOF-Cal GSI194.3 MeVLow Flux HighProtonGood00:0000:14    

1 cm dense bone (in isocentre)
4.5 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1.2 MHz on LGAD

WET measurement

  1   Sat Mar 30 06:34:39 2024 Bernhard PilslAnd a new testbeam starts :D            
  2   Sat Mar 30 06:53:31 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonUnknown   Normal  
about to start

geo and eudaq ini attached
Attachment 1: mpw4.ini
# example init file: Ex0.ini
[LogCollector.log]
EULOG_GUI_LOG_FILE_PATTERN = $12D.log

[Producer.tracker_irgendwas]

[Producer.aida_tlu]
initid= 20210115
verbose = 1
ConnectionFile= "file:///home/pct/frameworks/trackereudaq/user/tlu/misc/aida_tlu/aida_tlu_connection.xml"
#ConnectionFile= "file:///home/tlu-ma/latesteudaq/eudaq/user/tlu/misc/aida_tlu/aida_tlu_connection.xml" #for TLU MAUS
DeviceName = "aida_tlu.controlhub"
#DeviceName = "aida_tlu.udp"
TLUmod = "1e"
# number of HDMI inputs, leave 4 even if you only use fewer inputs
nDUTs = 4
nTrgIn = 6
# 0= False (Internal Reference OFF), 1= True
intRefOn = 0
VRefInt = 2.5
VRefExt = 1.3
# I2C address of the bus expander on Enclustra FPGA
I2C_COREEXP_Addr = 0x21
# I2C address of the Si5345
I2C_CLK_Addr = 0x68
# I2C address of 1st AD5665R
I2C_DAC1_Addr = 0x13
# I2C address of 2nd AD5665R
I2C_DAC2_Addr = 0x1F
# address of unique Id number EEPROM
I2C_ID_Addr = 0x50
#I2C address of 1st expander PCA9539PW~/
I2C_EXP1_Addr = 0x74
#I2C address of 2st expander PCA9539PW
I2C_EXP2_Addr = 0x75
#I2C address of AD5665R on powermodule
I2C_DACModule_Addr = 0x1CnoiseTrim
# Max value for control voltage on PMTs (usually 1 V)
PMT_vCtrlMax= 1.0
#I2C address of 1st expander PCA9539PW on powermodule
I2C_EXP1Module_Addr = 0x76
#I2C address of 2nd expander PCA9539PW on powermodule
I2C_EXP2Module_Addr = 0x77


##CONFCLOCK 0= skip clock configuration, 1= configure si5345
CONFCLOCK= 1
#CLOCK_CFG_FILE = "/home/pct-eudaq/latesteudaq/trackereudaq/user/caribou/MPW3/csv/20mhz_out2.txt"
#CLOCK_CFG_FILE = "/home/tlu-ma/mpw3/configs/20mhz_out2.txt"
CLOCK_CFG_FILE = "/home/pct/frameworks/trackereudaq/user/tlu/misc/aida_tlu/aida_tlu_clk_config.txt"
#CLOCK_CFG_FILE = "~/latesteudaq/trackereudaq/user/eudet/misc/hw_conf/aida_tlu/aida_tlu_clk_config.txt" # for TLU MAUS

[Producer.RD50_MPW4_0]
# general
log_level=INFO
# configuration
config_file="config.cfg"

[LogCollector.log]
# Currently, all LogCollectors have a hardcoded runtime name: log
EULOG_GUI_LOG_FILE_PATTERN = maus_$12D.log
# the $12D will be converted a data/time string with 12 digits.

[Producer.elog1]
elog_installation = "/home/pct/frameworks/elog/elog"
elog_host = "elog.hephy.at"
elog_port = 443
elog_logbook = "testbeam-MA2024"
att_stop_time = "t-Stop"
att_start_time = "t-Start"
att_run_number = "Run Number"
att_run_duration = "Duration_min"
color = ""

#simply paste configuration of your Elog logbook
Comment = Testbeams at MedAustron in 2024
Admin user = bergi, maks, bpilsl
Self register = 3

Attributes = Author, Subject, Run Number, DUT, Beam Energy, Rate Setting, Particle Type, Data, t-Start, t-Stop, Duration_min, Frontend
Options DUT = common, DSSD-Tracker, RD50-MPW4, TJ-Monopix2
Extendable options = DUT, Beam Energy, Rate Setting
Options Data = Unknown, Good, Crap
Options Beam Energy = 800 MeV, 252.7 MeV, 194.3 MeV, 175.3 MeV, 145.4 MeV, 100.4 MeV, 83 MeV, 62.4 MeV
Options Particle Type = Proton, Carbon
Options Rate Setting = Low Flux Very Low, Low Flux Low, Low Flux Medium, Low Flux High
Options Frontend = Normal, Normal Casc, HV, HV Casc
Quick filter = Date, Subject, Run Number, DUT, Beam Energy

Menu commands =  List, New, Edit, Delete, Reply, Duplicate, Move to, Find, Help
List Menu commands = New, Find, Select, Logout, Config, Help  
Guest List Menu commands = Find, Login, Help  
Guest menu commands = List, Find, Login, Help

##################################################################

Attachment 2: detectors.geo
[TLU_0]
role = auxiliary
type = tlu
number_of_pixels = 0, 0
pixel_pitch = 0um, 0um
position = 0mm, 0mm, 0mm
orientation = 0deg, 0deg, 0deg
time_resolution = 0ns

[dssd_5_1_1]
type = dssd
number_of_pixels = 512, 512
pixel_pitch = 100um, 50um
position = 0mm, 0mm, 0mm
orientation = 0deg, 0deg, 0deg
spatial_resolution = 29um,14.5um
material_budget = 0.0032021081576535286
time_resolution = 10000s

[dssd_5_1_2]
type = dssd
number_of_pixels = 512, 512
pixel_pitch = 100um, 50um
position = 0mm, 0mm, 50mm
orientation = 0deg, 0deg, 0deg
spatial_resolution = 29um,14.5um
material_budget = 0.0032021081576535286
time_resolution = 10000s
#role = reference

[RD50_MPWx_base_0]
#mask_file = mask_maus.txt
role = dut
type = RD50_MPWx
number_of_pixels = 64, 64
pixel_pitch = 62um, 62um
position = 0mm, 0mm, 68mm
orientation = 90deg,0deg,180deg
orientation_mode = "zyx"
time_resolution = 25ns
material_budget = 0.00320305

[dssd_5_1_3]
type = dssd
number_of_pixels = 512, 512
pixel_pitch = 100um, 50um
position = 0mm, 0mm, 181mm
orientation = 0deg, 0deg, 0deg
spatial_resolution = 29um,14.5um
material_budget = 0.0032021081576535286
time_resolution = 10000s
role = reference

[dssd_5_1_4]
type = dssd
number_of_pixels = 512, 512
pixel_pitch = 100um, 50um
position = 0mm, 0mm, 231mm
orientation = 0deg, 0deg, 0deg
spatial_resolution = 29um,14.5um
material_budget = 0.0032021081576535286
time_resolution = 10000s
  10   Sat Mar 30 07:59:55 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonCrap   Normal  
currently no beam
  11   Sat Mar 30 08:05:59 2024 Christian IrmlerRD50-MPW4999           

Tracker calibration run: mpw4-tj-monopix2_00-000999.xml
Generated global xml file for MPW4 shift: mpw4-tj-monopix2_TLU_00-000999.xml 

Previous local runs and xml files (mpw4-tj-monopix2_00-000212.xml) are unusable, because sensor L5.1.1.0 had a loose cotact and thus low gain.
Fixed by disconnecting and reconnecting.

  13   Sat Mar 30 08:34:12 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonGood   Normal  
beam should be back, there was something in the nozzle too
  14   Sat Mar 30 08:38:21 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonGood   Normal  
beam not back, fake news
  16   Sat Mar 30 08:56:25 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonCrap   Normal  
waiting for beam
Performing MTS restart
  18   Sat Mar 30 09:15:13 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonCrap   Normal  
moved entire setup a bit in order too better focus beam on MPW4 (hopefully)
  19   Sat Mar 30 09:25:05 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonCrap   Normal  
bea is back Big grin