ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Data t-Startdown t-Stop Duration_min Frontend Phantom Phantom thickness
  204   Sat Dec 14 15:42:32 2024 Felix Ulrich-Purplastic mouse radiography66TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood01:2101:3413 plastic mouse 

pos x=250, posy=75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  96   Sun Jun 9 01:27:38 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen25TOF-Cal GSI194.3 MeVLow Flux HighProtonGood01:1601:30    

3 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 600 kHz on LGAD

WET measurement

  203   Sat Dec 14 15:42:01 2024 Felix Ulrich-Purplastic mouse radiography65TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood01:0801:2012 plastic mouse 

pos x=250, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  95   Sun Jun 9 01:26:56 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen24TOF-Cal GSI145.4 MeVLow Flux HighProtonGood01:0201:14    

2 cm dense bone (in isocentre)
2.1 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 315 kHz on LGAD

WET measurement

  202   Sat Dec 14 15:41:43 2024 Felix Ulrich-Purplastic mouse radiography64TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:5401:0817 plastic mouse 

pos x=175, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  201   Sat Dec 14 15:41:19 2024 Felix Ulrich-Purplastic mouse radiography63TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:3700:5417 plastic mouse 

pos x=100, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  94   Sun Jun 9 01:25:26 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen23TOF-Cal GSI194.3 MeVLow Flux HighProtonGood00:3001:02    

2 cm dense bone (in isocentre)
- Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1 MHz on LGAD

interlock at 00:31 till 00:50 --> 19min break

WET measurement

  200   Sat Dec 14 15:40:45 2024 Felix Ulrich-Purplastic mouse radiography62TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:2200:3715 plastic mouse 

pos x=25, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  93   Sun Jun 9 01:22:48 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen22TOF-Cal GSI145.4 MeVLow Flux HighProtonGood00:1400:23    

1 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 600 kHz on LGAD

WET measurement

  199   Sat Dec 14 15:40:09 2024 Felix Ulrich-Purplastic mouse radiography61TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:0900:2213 plastic mouse 

pos x=-25, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  92   Sun Jun 9 00:12:41 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen21TOF-Cal GSI194.3 MeVLow Flux HighProtonGood00:0000:14    

1 cm dense bone (in isocentre)
4.5 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1.2 MHz on LGAD

WET measurement

  1   Sat Mar 30 06:34:39 2024 Bernhard PilslAnd a new testbeam starts :D            
  2   Sat Mar 30 06:53:31 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonUnknown   Normal  
about to start

geo and eudaq ini attached
  10   Sat Mar 30 07:59:55 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonCrap   Normal  
currently no beam
  11   Sat Mar 30 08:05:59 2024 Christian IrmlerRD50-MPW4999           

Tracker calibration run: mpw4-tj-monopix2_00-000999.xml
Generated global xml file for MPW4 shift: mpw4-tj-monopix2_TLU_00-000999.xml 

Previous local runs and xml files (mpw4-tj-monopix2_00-000212.xml) are unusable, because sensor L5.1.1.0 had a loose cotact and thus low gain.
Fixed by disconnecting and reconnecting.

  13   Sat Mar 30 08:34:12 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonGood   Normal  
beam should be back, there was something in the nozzle too
  14   Sat Mar 30 08:38:21 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonGood   Normal  
beam not back, fake news
  16   Sat Mar 30 08:56:25 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonCrap   Normal  
waiting for beam
Performing MTS restart
  18   Sat Mar 30 09:15:13 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonCrap   Normal  
moved entire setup a bit in order too better focus beam on MPW4 (hopefully)
  19   Sat Mar 30 09:25:05 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonCrap   Normal  
bea is back Big grin