Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2024, Page 10 of 11  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Settingdown Particle Type Data t-Start t-Stop Duration_min Frontend Phantom Phantom thickness
  186   Sat Dec 14 15:26:18 2024 Felix Ulrich-PurWET measurement slabs47TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon205.2 MeV/uLow Flux HighHeliumGood19:1619:2913 Dense Bone Slabs5cm

5cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset

3MHz Ramon 300kHz TRB

  187   Sat Dec 14 15:27:08 2024 Felix Ulrich-PurWET measurement slabs48TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon147.2 MeV/uLow Flux HighHeliumGood19:3019:5020 Dense Bone Slabs5cm

5cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset

1.5MHz Ramon

Wave crashes if 1 TDC disappears in dog d, DABC is still running

  188   Sat Dec 14 15:28:46 2024 Felix Ulrich-Purthreshold and preamp tests49TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood20:0420:095   

TRB Setup: 260V bias and 250mA pre-amps, threshold 10000 (was too high)

Diamond: 900mA, threshold 1000 offset

3.5MHz Ramon

  189   Sat Dec 14 15:30:23 2024 Felix Ulrich-Purthreshold and preamp tests50TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood20:1920:3516   

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000 (looks good, clustersize max at ~3)

Diamond: 900mA, threshold 1000 offset

4MHz Ramon 370kHz TRB

  190   Sat Dec 14 15:31:32 2024 Felix Ulrich-Purplastic mouse radiography51TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood21:1421:3016 plastic mouse 

before run, mouse was aligned with lasers and shift of beam w.r.t. sensor center was taken into account

pos x=250, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  191   Sat Dec 14 15:33:35 2024 Felix Ulrich-Purplastic mouse radiography53TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood21:3321:5724 plastic mouse 

run 52 was crap

pos x=175, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  192   Sat Dec 14 15:34:50 2024 Felix Ulrich-Purplastic mouse radiography54TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood21:5822:1022 plastic mouse 

pos x=100, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  193   Sat Dec 14 15:35:56 2024 Felix Ulrich-Purplastic mouse radiography55TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood22:1222:4533 plastic mouse 

pos x=25, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  194   Sat Dec 14 15:36:37 2024 Felix Ulrich-Purplastic mouse radiography56TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood22:4623:0014 plastic mouse 

pos x=-25, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  195   Sat Dec 14 15:37:26 2024 Felix Ulrich-Purplastic mouse radiography57TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood23:0223:1614 plastic mouse 

pos x=-100, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  196   Sat Dec 14 15:37:48 2024 Felix Ulrich-Purplastic mouse radiography58TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood23:1723:3013 plastic mouse 

pos x=-175, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  197   Sat Dec 14 15:39:11 2024 Felix Ulrich-Purplastic mouse radiography59TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood23:3323:4613 plastic mouse 

pos x=-175, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  198   Sat Dec 14 15:39:42 2024 Felix Ulrich-Purplastic mouse radiography60TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood23:5000:0818 plastic mouse 

pos x=-100, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  199   Sat Dec 14 15:40:09 2024 Felix Ulrich-Purplastic mouse radiography61TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:0900:2213 plastic mouse 

pos x=-25, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  200   Sat Dec 14 15:40:45 2024 Felix Ulrich-Purplastic mouse radiography62TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:2200:3715 plastic mouse 

pos x=25, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  201   Sat Dec 14 15:41:19 2024 Felix Ulrich-Purplastic mouse radiography63TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:3700:5417 plastic mouse 

pos x=100, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  202   Sat Dec 14 15:41:43 2024 Felix Ulrich-Purplastic mouse radiography64TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:5401:0817 plastic mouse 

pos x=175, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  203   Sat Dec 14 15:42:01 2024 Felix Ulrich-Purplastic mouse radiography65TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood01:0801:2012 plastic mouse 

pos x=250, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  204   Sat Dec 14 15:42:32 2024 Felix Ulrich-Purplastic mouse radiography66TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood01:2101:3413 plastic mouse 

pos x=250, posy=75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  205   Sat Dec 14 15:43:01 2024 Felix Ulrich-Purplastic mouse radiography67TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood01:3501:5116 plastic mouse 

pos x=175, posy=75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

ELOG V3.1.5-fc6679b