Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2024, Page 1 of 11  Not logged in ELOG logo
Entry  Sat Dec 14 15:31:32 2024, Felix Ulrich-Pur, plastic mouse radiography, 51, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 21:14, 21:30, 16, , plastic mouse,  
Entry  Sat Dec 14 15:33:35 2024, Felix Ulrich-Pur, plastic mouse radiography, 53, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 21:33, 21:57, 24, , plastic mouse,  
Entry  Sat Dec 14 15:34:50 2024, Felix Ulrich-Pur, plastic mouse radiography, 54, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 21:58, 22:10, 22, , plastic mouse,  
Entry  Sat Dec 14 15:35:56 2024, Felix Ulrich-Pur, plastic mouse radiography, 55, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 22:12, 22:45, 33, , plastic mouse,  
Entry  Sat Dec 14 15:36:37 2024, Felix Ulrich-Pur, plastic mouse radiography, 56, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 22:46, 23:00, 14, , plastic mouse,  
Entry  Sat Dec 14 15:37:26 2024, Felix Ulrich-Pur, plastic mouse radiography, 57, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 23:02, 23:16, 14, , plastic mouse,  
Entry  Sat Dec 14 15:37:48 2024, Felix Ulrich-Pur, plastic mouse radiography, 58, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 23:17, 23:30, 13, , plastic mouse,  
Entry  Sat Dec 14 15:39:11 2024, Felix Ulrich-Pur, plastic mouse radiography, 59, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 23:33, 23:46, 13, , plastic mouse,  
Entry  Sat Dec 14 15:39:42 2024, Felix Ulrich-Pur, plastic mouse radiography, 60, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 23:50, 00:08, 18, , plastic mouse,  
Entry  Sat Dec 14 15:40:09 2024, Felix Ulrich-Pur, plastic mouse radiography, 61, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 00:09, 00:22, 13, , plastic mouse,  
Entry  Sat Dec 14 15:40:45 2024, Felix Ulrich-Pur, plastic mouse radiography, 62, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 00:22, 00:37, 15, , plastic mouse,  
Entry  Sat Dec 14 15:41:19 2024, Felix Ulrich-Pur, plastic mouse radiography, 63, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 00:37, 00:54, 17, , plastic mouse,  
Entry  Sat Dec 14 15:41:43 2024, Felix Ulrich-Pur, plastic mouse radiography, 64, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 00:54, 01:08, 17, , plastic mouse,  
Entry  Sat Dec 14 15:42:01 2024, Felix Ulrich-Pur, plastic mouse radiography, 65, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 01:08, 01:20, 12, , plastic mouse,  
Entry  Sat Dec 14 15:42:32 2024, Felix Ulrich-Pur, plastic mouse radiography, 66, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 01:21, 01:34, 13, , plastic mouse,  
Entry  Sat Dec 14 15:43:01 2024, Felix Ulrich-Pur, plastic mouse radiography, 67, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 01:35, 01:51, 16, , plastic mouse,  
Entry  Sat Dec 14 15:43:45 2024, Felix Ulrich-Pur, plastic mouse radiography, 68, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 01:51, 02:07, 16, , plastic mouse,  
Entry  Sat Dec 14 15:45:05 2024, Felix Ulrich-Pur, plastic mouse radiography, 69, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 02:07, 02:25, 18, , plastic mouse,  
Entry  Sat Dec 14 15:45:36 2024, Felix Ulrich-Pur, plastic mouse radiography, 70, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 02:25, 02:45, 20, , plastic mouse,  
Entry  Sat Dec 14 15:46:16 2024, Felix Ulrich-Pur, plastic mouse radiography, 71, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 02:46, 03:03, 17, , plastic mouse,  
ELOG V3.1.5-fc6679b