ID |
Date |
Author |
Subject |
Run Number |
DUT |
Beam Energy |
Rate Setting |
Particle Type |
Data |
t-Start |
t-Stop |
Duration_min |
Frontend |
Phantom |
Phantom thickness |
Text |
|
11
|
Sat Mar 30 08:05:59 2024 |
Christian Irmler | RD50-MPW4 | 999 | | | | | | | | | | | | Tracker calibration run: mpw4-tj-monopix2_00-000999.xml
Generated global xml file for MPW4
shift: mpw4-tj-monopix2_TLU_00-000999.xml |
|
80
|
Sat Jun 8 21:41:04 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs Calibrationcurve | 9 | TOF-Cal GSI | 62.4 MeV | Low Flux High | Proton | Good | 20:55 | 21:21 | | | | | changed back to high due to beamsize vs
LGAD size factor
650 khz on Ramon (after 5 Layers of |
|
148
|
Sat Dec 14 12:56:38 2024 |
Felix Ulrich-Pur | Shift 23.11.24 low flux He test with RaMon | 9 | RaMon | 177.8 MeV/u | Low Flux High | Helium | Good | 06:40 | 06:41 | 1 | | | | Mean rate per spill~ 4.5e6 p/s (online
estimation without proper analysis) |
|
218
|
Sat Dec 14 15:50:19 2024 |
Felix Ulrich-Pur | LGAD+Diamond test with clinical carbon beam | 80 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 402MeV/u | | Carbon | Good | 05:15 | 05:50 | 35 | | | | Carbon Deg10 (clinical rate)
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
79
|
Sat Jun 8 20:11:00 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs Calibrationcurve | 8 | TOF-Cal GSI | 83 MeV | Low Flux Medium | Proton | Good | 19:42 | 20:51 | | | | | 300 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 35kHz
on LGAD |
|
147
|
Sat Dec 14 12:56:05 2024 |
Felix Ulrich-Pur | Shift 23.11.24 low flux He test with RaMon | 8 | RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 06:39 | 06:40 | 1 | | | | Mean rate per spill~ 5e6 p/s (online estimation
without proper analysis) |
|
217
|
Sat Dec 14 15:49:58 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 79 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 04:51 | 05:05 | 14 | | plastic mouse | | pos x=250, posy=-175
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
216
|
Sat Dec 14 15:49:32 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 78 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 04:36 | 04:50 | 14 | | plastic mouse | | pos x=175, posy=-175
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
215
|
Sat Dec 14 15:49:12 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 77 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 04:22 | 04:36 | 14 | | plastic mouse | | pos x=100, posy=-175
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
214
|
Sat Dec 14 15:48:49 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 76 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 04:06 | 04:21 | 15 | | plastic mouse | | pos x=25, posy=-175
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
213
|
Sat Dec 14 15:48:26 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 75 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 03:52 | 04:05 | 13 | | plastic mouse | | pos x=-25, posy=-175
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
212
|
Sat Dec 14 15:47:59 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 74 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 03:35 | 03:51 | 16 | | plastic mouse | | pos x=-100, posy=-175
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
211
|
Sat Dec 14 15:47:29 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 73 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 03:20 | 03:55 | 25 | | plastic mouse | | pos x=-175, posy=-175
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
210
|
Sat Dec 14 15:46:54 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 72 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 03:03 | 03:19 | 16 | | plastic mouse | | pos x=-175, posy=75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
137
|
Sun Aug 25 12:51:10 2024 |
tb-crew | only base | 71 | RD50-MPW4 | 62.4 MeV | Low Flux Very Low | Proton | Unknown | 25.08.2024 12:40:41 | 25.08.2024 12:51:37 | 10 | Normal | | | automatic log for run 71
Comment:
E-scan |
|
209
|
Sat Dec 14 15:46:16 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 71 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 02:46 | 03:03 | 17 | | plastic mouse | | pos x=-100, posy=75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
136
|
Sun Aug 25 12:39:45 2024 |
tb-crew | only base | 70 | RD50-MPW4 | 100.4 MeV | Low Flux Very Low | Proton | Unknown | 25.08.2024 12:24:36 | 25.08.2024 12:40:12 | 15 | Normal | | | automatic log for run 70
Comment:
E-scan |
|
208
|
Sat Dec 14 15:45:36 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 70 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 02:25 | 02:45 | 20 | | plastic mouse | | pos x=-25, posy=75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
78
|
Sat Jun 8 20:09:25 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs Calibrationcurve | 7 | TOF-Cal GSI | 100.4 MeV | Low Flux Medium | Proton | Good | 19:00 | 19:42 | | | | | 300 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 65kHz
on LGAD |
|
146
|
Sat Dec 14 12:55:41 2024 |
Felix Ulrich-Pur | Shift 23.11.24 low flux He test with RaMon | 7 | RaMon | 63.3 MeV/u | Low Flux Medium | Helium | Good | 06:35 | 06:36 | 1 | | | | Mean rate per spill~ 2-5E5 p/s (online
estimation without proper analysis) |
|