ID |
Date |
Author |
Subject |
Run Number |
DUT |
Beam Energy |
Rate Setting |
Particle Type |
Data |
t-Start |
t-Stop |
Duration_min |
Frontend |
Phantom |
Phantom thickness |
39
|
Sat Mar 30 11:55:55 2024 |
bp, ci, hh | useful datataking | 1023 | RD50-MPW4 | 800 MeV | Low Flux Low | Proton | Good | 30.03.2024 11:06:49 | 30.03.2024 11:58:22 | 51 | Normal | | |
automatic log for run 1023
Comment: |
40
|
Sat Mar 30 12:28:29 2024 |
bp, ci, hh | useful datataking | 1024 | RD50-MPW4 | 800 MeV | Low Flux Low | Proton | Good | 30.03.2024 11:58:45 | 30.03.2024 12:30:56 | 32 | Normal | | |
automatic log for run 1024
Comment:
changed thr to 1V (not 100% sure, configure was not executed) |
41
|
Sat Mar 30 12:54:24 2024 |
bp, ci, hh | useful datataking | 1025 | RD50-MPW4 | 800 MeV | Low Flux Low | Proton | Good | 30.03.2024 12:32:27 | 30.03.2024 12:56:51 | 24 | Normal | | |
automatic log for run 1025
Comment:
changed thr to 0.95V |
42
|
Sat Mar 30 13:28:15 2024 |
bp, ci, hh | useful datataking | 1026 | RD50-MPW4 | 800 MeV | Low Flux Low | Proton | Good | 30.03.2024 12:58:02 | 30.03.2024 13:30:42 | 32 | Normal | | |
automatic log for run 1026
Comment:
changed thr to 0.98V |
43
|
Sat Mar 30 13:35:09 2024 |
bp, ci, hh | useful datataking | | RD50-MPW4 | 800 MeV | Low Flux Low | Proton | Good | | | | Normal | | |
new users arrived |
166
|
Sat Dec 14 13:42:52 2024 |
Felix Ulrich-Pur | threshold and preamp tests | 27 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 63.3 MeV/u | Low Flux High | Helium | Good | 12:52 | 13:16 | 24 | | | |
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000 (changed threshold)
Diamond: 900mA, threshold 50 |
167
|
Sat Dec 14 13:45:34 2024 |
Felix Ulrich-Pur | threshold and preamp tests | 28 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 63.3 MeV/u | Low Flux High | Helium | Good | 13:20 | 13:32 | 2 | | | |
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000 (changed threshold)
Diamond: 900mA, threshold 1000 offset |
165
|
Sat Dec 14 13:40:47 2024 |
Felix Ulrich-Pur | threshold and preamp tests | 26 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 63.3 MeV/u | Low Flux High | Helium | Good | 12:35 | 12:49 | 14 | | | |
TRB Setup: 260V bias and 250mA pre-amps, threshold 10000 (changed threshold)
Diamond: 500mA, threshold 50 |
188
|
Sat Dec 14 15:28:46 2024 |
Felix Ulrich-Pur | threshold and preamp tests | 49 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 20:04 | 20:09 | 5 | | | |
TRB Setup: 260V bias and 250mA pre-amps, threshold 10000 (was too high)
Diamond: 900mA, threshold 1000 offset
3.5MHz Ramon |
189
|
Sat Dec 14 15:30:23 2024 |
Felix Ulrich-Pur | threshold and preamp tests | 50 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 20:19 | 20:35 | 16 | | | |
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000 (looks good, clustersize max at ~3)
Diamond: 900mA, threshold 1000 offset
4MHz Ramon 370kHz TRB |
190
|
Sat Dec 14 15:31:32 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 51 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 21:14 | 21:30 | 16 | | plastic mouse | |
before run, mouse was aligned with lasers and shift of beam w.r.t. sensor center was taken into account
pos x=250, posy=0
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
191
|
Sat Dec 14 15:33:35 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 53 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 21:33 | 21:57 | 24 | | plastic mouse | |
run 52 was crap
pos x=175, posy=0
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
192
|
Sat Dec 14 15:34:50 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 54 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 21:58 | 22:10 | 22 | | plastic mouse | |
pos x=100, posy=0
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
193
|
Sat Dec 14 15:35:56 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 55 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 22:12 | 22:45 | 33 | | plastic mouse | |
pos x=25, posy=0
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
194
|
Sat Dec 14 15:36:37 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 56 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 22:46 | 23:00 | 14 | | plastic mouse | |
pos x=-25, posy=0
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
195
|
Sat Dec 14 15:37:26 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 57 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 23:02 | 23:16 | 14 | | plastic mouse | |
pos x=-100, posy=0
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
196
|
Sat Dec 14 15:37:48 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 58 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 23:17 | 23:30 | 13 | | plastic mouse | |
pos x=-175, posy=0
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
197
|
Sat Dec 14 15:39:11 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 59 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 23:33 | 23:46 | 13 | | plastic mouse | |
pos x=-175, posy=-75
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
198
|
Sat Dec 14 15:39:42 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 60 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 23:50 | 00:08 | 18 | | plastic mouse | |
pos x=-100, posy=-75
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
199
|
Sat Dec 14 15:40:09 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 61 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 00:09 | 00:22 | 13 | | plastic mouse | |
pos x=-25, posy=-75
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |