Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-MA2018
testbeam-MA2019
testbeam-MA2020
testbeam-MA2021
testbeam-MA2023
testbeam-MA2024
Testbeams at MedAustron in 2023, Page 8 of 11
Not logged in
Find
|
Login
|
Help
New entries since:
Thu Jan 1 01:00:00 1970
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- DUT --
common
DSSD-Tracker
RD50-MPW3
TJ-Monopix2
-- Beam Energy --
800
252.7
145.4
100.4
83
62.4
194.3
Noise
175.3MeV
175.3
218 Entries
Goto page
Previous
1
,
2
,
3
...
7
, 8,
9
,
10
,
11
Next
All
ID
Date
Author
Subject
Run Number
DUT
Beam Energy
Rate Setting
Particle Type
Events
Data
t-Start
t-Stop
Duration_min
Frontend
Text
67
Thu Apr 27 15:52:02 2023
Felix Ulrich-Pur
sandwich TOF-iCT calibration
014
83
Low Flux Medium
Proton
Good
23.04.23 01:26 trigger on third LGAD
6 PMMA slabs (~1cm)
68
Thu Apr 27 15:52:25 2023
Felix Ulrich-Pur
sandwich TOF-iCT calibration
015
100.4
Low Flux Medium
Proton
Good
23.04.23 01:47 trigger on third LGAD
3 PMMA slabs (~0.5cm)
69
Thu Apr 27 15:53:11 2023
Felix Ulrich-Pur
sandwich TOF-iCT calibration
016
83
Low Flux Medium
Proton
Good
23.04.23 02:07 trigger on third LGAD
3 PMMA slabs (~0.5cm)
70
Thu Apr 27 15:53:54 2023
Felix Ulrich-Pur
sandwich TOF-iCT calibration
017
100.4
Low Flux Medium
Proton
Good
23.04.23 02:28 trigger on third LGAD
9 PMMA slabs (~1.5cm)
71
Thu Apr 27 15:54:15 2023
Felix Ulrich-Pur
sandwich TOF-iCT calibration
018
83
Low Flux Medium
Proton
Good
23.04.23 02:43 trigger on third LGAD
9 PMMA slabs (~1.5cm)
72
Thu Apr 27 15:55:35 2023
Felix Ulrich-Pur
sandwich TOF-iCT calibration
019
100.4
Low Flux Medium
Proton
Good
23.04.23 03:05 trigger on third LGAD
12 PMMA slabs (~2cm)
73
Thu Apr 27 15:56:18 2023
Felix Ulrich-Pur
sandwich TOF-iCT calibration
020
83
Low Flux Medium
Proton
Good
23.04.23 03:19 trigger on third LGAD
12 PMMA slabs (~2cm)
74
Thu Apr 27 15:56:37 2023
Felix Ulrich-Pur
sandwich TOF-iCT calibration
021
100.4
Low Flux Medium
Proton
Good
23.04.23 03:40 trigger on third LGAD
15 PMMA slabs (~2.5cm)
75
Thu Apr 27 15:57:31 2023
Felix Ulrich-Pur
sandwich TOF-iCT calibration
022
83
Low Flux Medium
Proton
Good
23.04.23 03:58 trigger on third LGAD
15 PMMA slabs (~2.5cm)
76
Thu Apr 27 15:58:04 2023
Felix Ulrich-Pur
sandwich TOF-iCT calibration
023
100.4
Low Flux Medium
Proton
Good
23.04.23 04:20 trigger on third LGAD
18 PMMA slabs (~3cm)
77
Thu Apr 27 15:58:35 2023
Felix Ulrich-Pur
sandwich TOF-iCT calibration
024
83
Low Flux Medium
Proton
Good
23.04.23 04:37 trigger on third LGAD
18 PMMA slabs (~3cm)
78
Thu Apr 27 15:59:00 2023
Felix Ulrich-Pur
sandwich TOF-iCT calibration
025
100.4
Low Flux Medium
Proton
Good
23.04.23 05:00 trigger on third LGAD
21 PMMA slabs (~3.5cm)
79
Thu Apr 27 15:59:29 2023
Felix Ulrich-Pur
sandwich TOF-iCT calibration
026
83
Low Flux Medium
Proton
Good
23.04.23 05:18 trigger on third LGAD
21 PMMA slabs (~3.5cm)
80
Thu Apr 27 15:59:52 2023
Felix Ulrich-Pur
sandwich TOF-iCT radiography
027
100.4
Low Flux Medium
Proton
Good
23.04.23 05:55 trigger on third LGAD
1cm Al stair phantom profile view
(i.e. only 1cm Al) 0deg
81
Thu Apr 27 16:00:47 2023
Felix Ulrich-Pur
sandwich TOF-iCT radiography
028
83
Low Flux Medium
Proton
Good
23.04.23 07:35 trigger on third LGAD
1cm Al stair phantom profile view
(i.e. only 1cm Al) 0deg
82
Thu Apr 27 16:01:39 2023
Felix Ulrich-Pur
sandwich TOF-iCT radiography
029
83
Low Flux Medium
Proton
Good
23.04.23 09:36 trigger on third LGAD
1cm Al stair phantom frontal view
(i.e. 5 steps) 90deg
83
Thu Apr 27 16:02:23 2023
Felix Ulrich-Pur
sandwich TOF-iCT calibration
030
100.4
Low Flux Medium
Proton
Good
23.04.23 10:38 trigger on third LGAD
20 PMMA slabs
84
Thu Apr 27 16:03:21 2023
Felix Ulrich-Pur
sandwich TOF-iCT calibration
031
83
Low Flux Medium
Proton
Good
23.04.23 10:53 trigger on third LGAD
20 PMMA slabs
85
Thu Apr 27 16:03:48 2023
Felix Ulrich-Pur
sandwich TOF-iCT calibration
032
100.4
Low Flux Medium
Proton
Good
23.04.23 11:13 trigger on third LGAD
19 PMMA slabs
86
Thu Apr 27 16:04:40 2023
Felix Ulrich-Pur
sandwich TOF-iCT calibration
034
83
Low Flux Medium
Proton
Good
23.04.23 11:43 trigger on third LGAD
19 PMMA slabs
run 33 is missing as accelerator
Goto page
Previous
1
,
2
,
3
...
7
, 8,
9
,
10
,
11
Next
All
ELOG V3.1.5-fc6679b