Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2023, Page 8 of 11  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Data t-Start t-Stop Duration_mindown Frontend
  109   Sat May 6 10:01:28 2023 cibpdata-taking58RD50-MPW38005kHzProton931155Unknown06.05.2023 09:51:3206.05.2023 10:00:38 Normal
automatic log for run 58
Comment:
  110   Sat May 6 10:08:09 2023 cibpdata-taking RD50-MPW38005kHzProton Unknown   Normal
no MPX2 data atm, problem with datacollector
  111   Sat May 6 10:12:23 2023 cibpdata-taking59RD50-MPW38005kHzProton1039920Unknown06.05.2023 10:01:2406.05.2023 10:11:32 Normal
automatic log for run 59
Comment:
  112   Sat May 6 10:43:57 2023 cibpdata taking common800200kHzProton Unknown   Normal
adjusted table in height by ~-2mm
  113   Sat May 6 11:04:28 2023 cibpdata taking RD50-MPW3800200kHzProton Unknown   Normal
No beam since 30 min
Operator: "spills get rejected by ..."
  114   Sat May 6 11:13:04 2023 cibpdata taking RD50-MPW3800200kHzProton Unknown   Normal
MPS (whatever) restart necessary
No beam for another ~ 20 -30 min
  115   Sat May 6 11:21:47 2023 cibpdata taking60RD50-MPW3800200kHzProton193381Unknown06.05.2023 10:46:4406.05.2023 11:20:56 Normal
automatic log for run 60
Comment:
  116   Sat May 6 12:57:47 2023 cibpdata taking61RD50-MPW3800200kHzProton0Unknown06.05.2023 12:56:3406.05.2023 12:56:56 Normal
automatic log for run 61
Comment:
  117   Sat May 6 13:04:06 2023 cibpdata taking RD50-MPW3800200kHzProton Unknown   Normal
beam is back Smile
  118   Sat May 6 13:13:05 2023 cibpdata taking62RD50-MPW3800200kHzProton1336043Unknown06.05.2023 12:59:3306.05.2023 13:12:14 Normal
automatic log for run 62
Comment:
Sensors now 2 mm lower to increase hit rate on MPW3 (was slightly too high)
  119   Sat May 6 13:21:02 2023 cibpdata taking63RD50-MPW3800200kHzProton566713Unknown06.05.2023 13:12:3806.05.2023 13:20:11 Normal
automatic log for run 63
Comment:
  120   Sat May 6 13:44:59 2023 cibpmbpsdata taking65RD50-MPW3800200kHzProton12617213Unknown06.05.2023 13:26:4206.05.2023 13:44:08 Normal
automatic log for run 65
Comment:
  121   Sat May 6 14:07:32 2023 cibpmbpsdata taking66RD50-MPW3800200kHzProton14540161Unknown06.05.2023 13:45:5406.05.2023 14:06:41 Normal
automatic log for run 66
Comment:
  122   Sat May 6 14:16:53 2023 Christian IrmlerSensor orientation           

Orientation of tracker, MPW3 and TJMP2

  123   Sat May 6 14:27:55 2023 cibpmbpsdata taking67RD50-MPW3252.7Low Flux MediumProton8797699Good06.05.2023 14:09:0806.05.2023 14:27:04 Normal Casc
automatic log for run 67
Comment:
  124   Sat May 6 15:42:54 2023 TB crewMPX2 MPW3 TB70RD50-MPW3800200kHzProton1284521Good06.05.2023 15:40:1006.05.2023 15:42:02 Normal Casc
automatic log for run 70
Comment:
  125   Sat May 6 15:47:03 2023 TB crewMPX2 MPW3 TB71RD50-MPW3800200kHzProton2164383Good06.05.2023 15:42:3006.05.2023 15:46:11 Normal Casc
automatic log for run 71
Comment:
  126   Sat May 6 15:50:05 2023 TB crewMPX2 MPW3 TB72RD50-MPW3800200kHzProton913881Good06.05.2023 15:47:5406.05.2023 15:49:13 Normal Casc
automatic log for run 72
Comment:
  127   Sat May 6 15:58:49 2023 TB crewMPX2 MPW3 TB73RD50-MPW3800200kHzProton3897223Good06.05.2023 15:52:1906.05.2023 15:57:58 Normal Casc
automatic log for run 73
Comment:
  128   Sat May 6 16:10:24 2023 TB crewMPX2 MPW3 TB74RD50-MPW3252.7Low Flux MediumProton4400593Good06.05.2023 16:03:5206.05.2023 16:09:32 Normal Casc
automatic log for run 74
Comment:
ELOG V3.1.5-fc6679b