Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2023, Page 8 of 11  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Data t-Start t-Stopdown Duration_min Frontend
  111   Sat May 6 10:12:23 2023 cibpdata-taking59RD50-MPW38005kHzProton1039920Unknown06.05.2023 10:01:2406.05.2023 10:11:32 Normal
automatic log for run 59
Comment:
  109   Sat May 6 10:01:28 2023 cibpdata-taking58RD50-MPW38005kHzProton931155Unknown06.05.2023 09:51:3206.05.2023 10:00:38 Normal
automatic log for run 58
Comment:
  107   Sat May 6 09:50:52 2023 cibpdata-taking57RD50-MPW38005kHzProton2315658Unknown06.05.2023 09:24:5806.05.2023 09:50:02 Normal
automatic log for run 57
Comment:
  103   Sat May 6 09:24:21 2023 cibpdata-taking56RD50-MPW3800200kHzProton1243318Unknown06.05.2023 09:18:2406.05.2023 09:23:30 Normal
automatic log for run 56
Comment:
  102   Sat May 6 09:17:42 2023 cibpdata-taking55RD50-MPW3800200kHzProton1Unknown06.05.2023 09:16:1906.05.2023 09:16:52 Normal
automatic log for run 55
Comment:
sensors moved 2mm in -y (away from LCR1, towards rack)
  101   Sat May 6 09:07:40 2023 cibp1st tests54RD50-MPW3800200kHzProton926384Unknown06.05.2023 09:01:5206.05.2023 09:06:49 Normal
automatic log for run 54
Comment:
moved sensors 2mm towards LCR1 (+y for tracker)
apperently wrong direction, adjusting again
  98   Sat May 6 08:59:49 2023 cibp1st tests53RD50-MPW3800200kHzProton1Unknown06.05.2023 08:57:0506.05.2023 08:58:59 Normal
automatic log for run 53
Comment:
trying to run mpx2 without trigger loss
  97   Sat May 6 08:45:07 2023 cibp1st tests52RD50-MPW3800200kHzProton8992077Unknown06.05.2023 08:12:3106.05.2023 08:44:16 Normal
automatic log for run 52
Comment:
trying to run mpx2 without trigger loss
  96   Sat May 6 08:11:28 2023 cibp1st tests51RD50-MPW3800200kHzProton1Unknown06.05.2023 08:10:2606.05.2023 08:10:38 Normal
automatic log for run 51
Comment:
trying to run mpx2
  94   Sat May 6 08:08:45 2023 cibp1st tests50RD50-MPW3800200kHzProton868396Unknown06.05.2023 07:51:2206.05.2023 08:07:55 Normal
automatic log for run 50
Comment:
testing for the moment
might (not) be useful data
  93   Sat May 6 07:49:04 2023 cibp1st tests49RD50-MPW3800200kHzProton692561Unknown06.05.2023 07:34:2006.05.2023 07:48:13 Normal
automatic log for run 49
Comment:

beam profile tracker -> attachement 1
  91   Fri May 5 17:53:22 2023   47common800Low Flux LowProton85154Unknown05.05.2023 17:51:1905.05.2023 17:52:33 Normal
automatic log for run 47
  90   Fri May 5 16:00:29 2023   45common800Low Flux LowProton104700Unknown05.05.2023 15:58:2305.05.2023 15:59:40 Normal
automatic log for run 45
  1   Sat Feb 18 14:48:36 2023 Bernhard PilslMPW3 Kalibration / Config Files           

Initial config files for the RD50_MPW3 Peary device

  4   Sat Feb 18 22:17:31 2023 Bernhard PilslAttention RUN NUMBER           

Due to bug in Elog-RC entries here for the shift on 18.02.2023 are bigger (+1) than the one stored in the data file names
eg run 9999 ( in name of *.raw files) is listed as 10000 in here

  5   Sat Feb 18 22:18:39 2023 BP_PSBeam common8005kHzProton Unknown    
Status 22:19, waiting for beam, vakuum Problem in der Quelle
  6   Sat Feb 18 22:26:47 2023 BP_PSBeam common8005kHzProton Unknown    
Status: Beam bekommen um 22:23
  9   Sat Feb 18 22:37:45 2023 BP_PSINFO common8005kHzProton Unknown    
z positions:
DSSD1: 0mm
DSSD2: 48mm
MPW3: 35mm
DSSD3: 127mm
DSSD4: 50mm
All positions relativ to previous position!
  16   Sat Feb 18 23:58:44 2023 BP_PSINFO common8005kHzProton Unknown    
Moved DUT 4mm before run 9
  34   Sun Feb 19 02:05:04 2023 BP_PSINFO common8005kHzProton Unknown    
change TH before run 26, chip was getting noisy to 1,15V
Before it was at 1,08
ELOG V3.1.5-fc6679b