Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2023, Page 6 of 11  Not logged in ELOG logo
IDdown Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Data t-Start t-Stop Duration_min Frontend
  119   Sat May 6 13:21:02 2023 cibpdata taking63RD50-MPW3800200kHzProton566713Unknown06.05.2023 13:12:3806.05.2023 13:20:11 Normal
automatic log for run 63
Comment:
  118   Sat May 6 13:13:05 2023 cibpdata taking62RD50-MPW3800200kHzProton1336043Unknown06.05.2023 12:59:3306.05.2023 13:12:14 Normal
automatic log for run 62
Comment:
Sensors now 2 mm lower to increase hit rate on MPW3 (was slightly too high)
  117   Sat May 6 13:04:06 2023 cibpdata taking RD50-MPW3800200kHzProton Unknown   Normal
beam is back Smile
  116   Sat May 6 12:57:47 2023 cibpdata taking61RD50-MPW3800200kHzProton0Unknown06.05.2023 12:56:3406.05.2023 12:56:56 Normal
automatic log for run 61
Comment:
  115   Sat May 6 11:21:47 2023 cibpdata taking60RD50-MPW3800200kHzProton193381Unknown06.05.2023 10:46:4406.05.2023 11:20:56 Normal
automatic log for run 60
Comment:
  114   Sat May 6 11:13:04 2023 cibpdata taking RD50-MPW3800200kHzProton Unknown   Normal
MPS (whatever) restart necessary
No beam for another ~ 20 -30 min
  113   Sat May 6 11:04:28 2023 cibpdata taking RD50-MPW3800200kHzProton Unknown   Normal
No beam since 30 min
Operator: "spills get rejected by ..."
  112   Sat May 6 10:43:57 2023 cibpdata taking common800200kHzProton Unknown   Normal
adjusted table in height by ~-2mm
  111   Sat May 6 10:12:23 2023 cibpdata-taking59RD50-MPW38005kHzProton1039920Unknown06.05.2023 10:01:2406.05.2023 10:11:32 Normal
automatic log for run 59
Comment:
  110   Sat May 6 10:08:09 2023 cibpdata-taking RD50-MPW38005kHzProton Unknown   Normal
no MPX2 data atm, problem with datacollector
  109   Sat May 6 10:01:28 2023 cibpdata-taking58RD50-MPW38005kHzProton931155Unknown06.05.2023 09:51:3206.05.2023 10:00:38 Normal
automatic log for run 58
Comment:
  108   Sat May 6 09:51:57 2023 cibpdata-taking RD50-MPW38005kHzProton Unknown   Normal
changed mpx2 settings by max
  107   Sat May 6 09:50:52 2023 cibpdata-taking57RD50-MPW38005kHzProton2315658Unknown06.05.2023 09:24:5806.05.2023 09:50:02 Normal
automatic log for run 57
Comment:
  105   Sat May 6 09:41:50 2023 cibpdata-taking RD50-MPW38005kHzProton Unknown   Normal
changed rate to 5kHz
  104   Sat May 6 09:31:55 2023 cibpdata-taking RD50-MPW38005kHzProton Unknown   Normal
alignment of MPW3 seems better
  103   Sat May 6 09:24:21 2023 cibpdata-taking56RD50-MPW3800200kHzProton1243318Unknown06.05.2023 09:18:2406.05.2023 09:23:30 Normal
automatic log for run 56
Comment:
  102   Sat May 6 09:17:42 2023 cibpdata-taking55RD50-MPW3800200kHzProton1Unknown06.05.2023 09:16:1906.05.2023 09:16:52 Normal
automatic log for run 55
Comment:
sensors moved 2mm in -y (away from LCR1, towards rack)
  101   Sat May 6 09:07:40 2023 cibp1st tests54RD50-MPW3800200kHzProton926384Unknown06.05.2023 09:01:5206.05.2023 09:06:49 Normal
automatic log for run 54
Comment:
moved sensors 2mm towards LCR1 (+y for tracker)
apperently wrong direction, adjusting again
  100   Sat May 6 09:04:46 2023 cibp1st tests RD50-MPW3800200kHzProton Unknown   Normal
apperently wrong direction, adjusting again
moved 2mm (from origin) in other direction
  99   Sat May 6 09:02:17 2023 cibp1st tests RD50-MPW3800200kHzProton Unknown   Normal
moved whole setup by ~2mm in x
ELOG V3.1.5-fc6679b