Message ID: 203     Entry time: Sun Oct 15 02:17:53 2023
Author: tb crew 
Subject: RD50-MPW3 
Run Number: 39 
DUT: RD50-MPW3 
Beam Energy: 800 
Rate Setting: Low Flux Low 
Particle Type: Proton 
Events:  
Data: Unknown 
t-Start: 15.10.2023 02:05:42 
t-Stop: 15.10.2023 02:18:17 
Duration_min: 12 
Frontend: Normal 
automatic log for run 39
Comment:
Attachment 1: peary.cfg  1 kB  | Show | Hide all | Show all
Attachment 2: matrix_config_base.txt  32 kB  | Show | Hide all | Show all
Attachment 3: matrix_config_piggy.txt  32 kB  | Show | Hide all | Show all
Attachment 4: mpw3.conf  3 kB  | Hide | Hide all | Show all
# example config file: Ex0.conf
[RunControl]
#pCT_STOP_RUN_AFTER_N_SECONDS = 3000000
# from the base RunControl.cc
#EUDAQ_CTRL_PRODUCER_LAST_START = my_pd0
#EUDAQ_CTRL_PRODUCER_FIRST_STOP = my_pd0
# Steer which values to display in the GUI: producerName and displayed value are seperated by a ",". 
ADDITIONAL_DISPLAY_NUMBERS = "log,_SERVER"


[Producer.aida_tlu]
## GENERAL PARAMETERS
verbose= 1
skipconf= 0
confid= 20201311
delayStart= 200  

## HDMI CONFIGURATION
#  4-bits to determine direction of HDMI pins
HDMI1_set= 0x7 #1= output (driven by TLU), 0 = input. bit 0=CONT, 1=SPARE, 2=TRIG, 3=BUSY for eudet, Busy needs to be 0. (0b0111 = 0x7)
HDMI2_set= 0x7
HDMI3_set= 0x7
HDMI4_set= 0x7
#  Clock source (0= no clock, 1= Si5345, 2= FPGA)
HDMI1_clk = 1
HDMI2_clk = 1
HDMI3_clk = 1
HDMI4_clk = 1
#  Enable/Disable clock on differential LEMO
LEMOclk = 0

## PMT POWER CONFIGURATION
PMT1_V= 0.8 #0.6363 #Szinti 4x4cm
PMT2_V= 0.8 #0.6363 #Szinti 4x4cm
PMT3_V= 0.8
PMT4_V= 0.0

## TRIGGER CONFIGURATION
trigMaskHi = 0x00000000
trigMaskLo = 0x00000040 #0x00000008 #0x00010002 #0x00000001  #8 coinc1+2
in0_STR = 0	# 0 
in0_DEL = 0	# 18
in1_STR = 0	# 0
in1_DEL = 0	# 18
in2_STR = 0	# 0
in2_DEL = 0 	# 0
in3_STR = 0
in3_DEL = 0
in4_STR = 0
in4_DEL = 0
in5_STR = 0 #streches pulse from 6.25ns (at 0) to 12.5ns
in5_DEL = 0
# Generate internal triggers (in Hz, 0= no triggers)
InternalTriggerFreq= 0 #4000 #00

## DISCRIMINATOR THRESHOLDS
DDACThreshold0 = -0.012 #-0.025 #-0.012
DACThreshold1 = -0.012 #-0.025 #-0.012
DACThreshold2 = -0.012
DACThreshold3 = -0.12
DACThreshold4 = -0.12 #-0.0066
DACThreshold5 = -0.12

## DUT CONFIGURATION
 # DUTMask Which DUTs are on
#DUTMask= 0x3 #6 bit 0= DUT1, bit 1= DUT2, bit 2= DUT3, bit 3= DUT4
DUTMask= 0x6

 # DUTMaskMode Define AIDA (11) or EUDET (00) mode (2 bits per DUT)
DUTMaskMode= 0x30 #0x00

 # In EUDET mode: 0 = standard trigger/busy mode, 1 = raising BUSY outside handshake vetoes triggers (2 bits per DUT, 0x3= DUT 4! -backwards!)
DUTMaskModeModifier= 0x30 #0x30 #0xC0 PS: Check what this does! 0x0 würde ich hier eingeben

 # Ignore the BUSY signal for a DUT (0xF)
DUTIgnoreBusy= 0xF #ignores triggers
DUTIgnoreShutterVeto= 0x0
EnableRecordData = 1


# EnableShutterMode: 0x0. If 1, shutter mode is enabled. If 0, shutter mode is disabled.
EnableShutterMode= 0x0
# Define which input is used for shutter source [0 - 5]
ShutterSource = 5
# 32-bit counter of clocks. Set to 0 to not use internal shutter generator.
InternalShutterInterval = 0
# 32-bit counter of clocks
ShutterOnTime = 0 #start of shutter after trigger
# 32-bit counter of clocks
ShutterVetoOffTime = 0 #time after input-trigger, until first trigger is sent to output
# 32-bit counter of clocks
ShutterOffTime = 200000000 #end of shutter after trigger #200000000 = 5s (multiples of 25ns)

## DATA COLLECTOR
EUDAQ_DC= tlu_dc

## TLU MONITOR PARAMETER
FileComment="mpw3"
PlotWindowSizeinns=40e9
MinSpillTimeOnins=4.5
MinSpilldownTimeins=0.5
ThreshEvBegin=1
ThreshEvEnd=1
ThreshPartBegin=1
ThreshPartEnd=1



[LogCollector.log]
# Currently, all LogCollectors have a hardcoded runtime name: log
# nothing


[DataCollector.tlu_dc]
EUDAQ_FW=native
# the format of data file
EUDAQ_FW_PATTERN= /media/silicon/testbeam_data/maus_231014/tlu_run$6R$X
# the name pattern of data file
# the $12D will be converted a data/time string with 12 digits.
# the $6R will be converted a run number string with 6 digits.
# the $X will be converted the suffix name of data file.
DISABLE_PRINT = 1


[Producer.RD50_MPW3_0]

[Producer.elog1]
start_cmd = ./scp_configs.sh
files2log = peary.cfg, matrix_config_base.txt, matrix_config_piggy.txt, mpw3.conf


[DataCollector.mpw3_dc]
# connection to the monitor
EUDAQ_MN = mpw3_mon
EUDAQ_FW = native
EUDAQ_FW_PATTERN = /media/silicon/testbeam_data/maus_231014/mpw3_run$6R$X
EUDAQ_DATACOL_SEND_MONITOR_FRACTION = 100
# config-parameters
DISABLE_PRINT = 1
XILINX_IP = 192.168.201.1

[Monitor.mpw3_mon]
ENABLE_PRINT = 0
ENABLE_STD_PRINT = 0
ENABLE_STD_CONVERTER = 1
FORWARD2GUI = 1