Message ID: 118     Entry time: Sat May 6 13:13:05 2023
Author: cibp 
Subject: data taking 
Run Number: 62 
DUT: RD50-MPW3 
Beam Energy: 800 
Rate Setting: 200kHz 
Particle Type: Proton 
Events: 1336043 
Data: Unknown 
t-Start: 06.05.2023 12:59:33 
t-Stop: 06.05.2023 13:12:14 
Duration_min:  
Frontend: Normal 
automatic log for run 62
Comment:
Sensors now 2 mm lower to increase hit rate on MPW3 (was slightly too high)