  319   Sat Oct 8 09:07:48 2022 Patrick Siebererramon + tracker + DUT8RD50-MPW3252.7  kurzGoodlowflux high       

short run for uploading to analysis

  320   Sat Oct 8 09:08:13 2022 Patrick Siebererramon + tracker + DUT9RD50-MPW3252.7  kurzGoodlowflux high       

TLU: 6,8M Tracker nur 4 M -> Let's reset FADC

  322   Sat Oct 8 09:33:59 2022 Patrick Siebererramon + tracker + DUT12RD50-MPW3252.7  9.8MGoodlowflux high       

repeat run 9 again ;)

run 11 used for new local runs of tracker - hvcmos_mpw3_20221008_11_TLU_00-000011.xml

tracker seems fine, at least in the beginning

again APV sync errors at the end of the run

  112   Sat Feb 27 23:40:54 2021 Christian IrmlerE Scan DSSD+SiC70SiC+DSSD tracker252.7II(BETA+EFE)Proton7E8Good        

Start 19:35:
Final MT=1, final BSY length =600 (2kHz), Trigger latency 41 optimal

HV 500V

  111   Sat Feb 27 23:39:57 2021 Christian IrmlerE Scan DSSD+SiC69SiC+DSSD tracker62.4II(BETA+EFE)Proton7E5Good        

Start 19:14:
Final MT=1, final BSY length =600 (2kHz), Trigger latency 41 optimal

HV 500V

  32   Sun Jan 10 07:24:46 2021 Maximilian TomaschekLowflux recommissioning36Ramon+Tracker252.7  7 spills 1e6 eventsGood  101 0  

Spotsize

  33   Sun Jan 10 07:26:16 2021 Maximilian TomaschekLowflux recommissioning37Ramon+Tracker194.3  7 spills 1e6 eventsGood  101 0  

Spotsize

  34   Sun Jan 10 07:26:31 2021 Maximilian TomaschekLowflux recommissioning38Ramon+Tracker175.3  7 spills 1e6 eventsGood  101 0  

Spotsize

  35   Sun Jan 10 07:26:42 2021 Maximilian TomaschekLowflux recommissioning39Ramon+Tracker145.4  7 spills 1e6 eventsGood  101 0  

Spotsize

  36   Sun Jan 10 07:26:58 2021 Maximilian TomaschekLowflux recommissioning40Ramon+Tracker100.4  7 spills 1e6 eventsGood  101 0  

Spotsize

  37   Sun Jan 10 07:27:37 2021 Maximilian TomaschekLowflux recommissioning45Ramon+Tracker83  7 spills 1e6 eventsGood  101 0  

Spotsize

  38   Sun Jan 10 07:27:55 2021 Maximilian TomaschekLowflux recommissioning47Ramon+Tracker62.4  7 spills 1e6 eventsGood  101 0  

Spotsize, max T 1 & BSY 50 -> rate zu hoch

  122   Tue Mar 2 15:34:49 2021 Patrick SiebererMPW2 Tracking85MPW2+tracker252.7I(EFE+SID0)Proton640kUnknown        

Start 23:24
Threshold MPW2: 960mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 500
2 Koinzidenz TLU und 3er Koinzidenz Messmodus am MPW

  297   Sun Nov 7 19:11:24 2021 Felix Ulrich-PurFluence loss meas 7.11.2126Drehtisch145.4II(BETA+EFE)Proton60e6Good      Alu0

Start: 15:19

1 cm Alu stair phantom on rotary table (0deg--> always 1cm Al in beam)

  298   Sun Nov 7 19:12:57 2021 Felix Ulrich-PurFluence loss meas 7.11.2127Drehtisch145.4II(BETA+EFE)Proton60e6Good      Alu90

Start: 16:40

1 cm Alu stair phantom on rotary table (90deg--> 0.2-1cm Alu)

  299   Sun Nov 7 19:13:36 2021 Felix Ulrich-PurFluence loss meas 7.11.2128Drehtisch100.4II(BETA+EFE)Proton60e6Good      Alu90

Start: 18:00

1 cm Alu stair phantom on rotary table (90deg)

  300   Sun Nov 7 19:28:49 2021 Felix Ulrich-PurFluence loss meas 7.11.2129Drehtisch100.4II(BETA+EFE)Proton60e6Good      Alu0

Start: 19:28

1 cm Alu stair phantom on rotary table (0deg)

  214   Tue Mar 16 15:37:49 2021 Patrick SiebererSiC strip sensor77SiC+DSSD tracker800VProton6.6MGood        

Energy Scan
03:06-5:18
MHz Rate
Danach: Abbauen

  105   Sat Feb 27 23:21:35 2021 Christian IrmlerHV Scan DSSD+SiC63SiC+DSSD tracker100.4II(BETA+EFE)Proton5E5Good        

Start 17:58:
Final MT=1, final BSY length =500 (2kHz), Trigger latency 41 optimal

HV 300V

  106   Sat Feb 27 23:29:33 2021 Christian IrmlerHV Scan DSSD+SiC64SiC+DSSD tracker100.4II(BETA+EFE)Proton5E5Good        

Start 18:09:
Final MT=1, final BSY length =500 (2kHz), Trigger latency 41 optimal

HV 200V