  MedAustron 2021, Page 18 of 18  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Typeup Events Data Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle
  301   Sun Nov 7 21:04:43 2021 Felix Ulrich-PurFluence loss meas 7.11.2130 100.4II(BETA+EFE)Proton40e6Good      none 

Start: 21.04

reference run 100.4MeV

  302   Sun Nov 21 13:51:53 2021 Simon WaidComparison SiC, Si, Si LGAD and Diamond1SiC+Si62.4I(EFE+SID0)Proton10000         

Bias voltage SiC: 800

Bias voltage Si: -150

From a beam perspective the Si detector was the first target, on oscilloscope  channel 1, SiC was the second target connected to oscilloscope channel 3.

Triggering source was the SiC detector.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

  303   Sun Nov 21 13:55:05 2021 Simon WaidComparison SiC, Si, Si LGAD and Diamond2SiC+Si62.4I(EFE+SID0)Proton1000000         

Bias voltage SiC: 800

Bias voltage Si: -150

From a beam perspective the Si detector was the first target, on oscilloscope  channel 1, SiC was the second target connected to oscilloscope channel 3.

Triggering source was the Si detector.

The compliancy of the SiC SMU triggered after approx. 50% of the events had been acquired after this event the HV for the SiC HV was shut down.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

  304   Sun Nov 21 14:05:18 2021 Simon WaidComparison SiC, Si, Si LGAD and Diamond3 62.4I(EFE+SID0)Proton10000         

Bias voltage SiC: 800

Bias voltage Si LGAD: -100

From a beam perspective the SiC detector was the first target, on oscilloscope channel 4, the Si LGAD was the second target connected to oscilloscope channel 1.

Triggering source was the Si LGAD detector. The SiC detector was most probably defective.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

  305   Sun Nov 21 14:53:00 2021 Simon WaidComparison SiC, Si, Si LGAD and Diamond4Diamond+LGAD62.4I(EFE+SID0)Proton100000         

Bias voltage Diamond: 500

Bias voltage Si LGAD: -100

From a beam perspective the Diamond detector was the first target, on oscilloscope channel 4, the Si LGAD was the second target connected to oscilloscope channel 1.

Triggering source was the Si LGAD detector.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

  306   Sat Dec 11 17:46:17 2021 Felix Ulrich-PurAlignment run1DSSD-Tracker800VProton Good      none 

Fluence loss measurement 11.12.2021

Start 14:45

 

  307   Sat Dec 11 17:47:45 2021 Felix Ulrich-PurAlignment run2DSSD-Tracker800VProton Good      none 

Fluence loss measurement 11.12.2021

 

 

  308   Sat Dec 11 17:47:52 2021 Felix Ulrich-PurAlignment run3DSSD-Tracker800VProton Good      none 

Fluence loss measurement 11.12.2021

 

 

  309   Sat Dec 11 17:48:08 2021 Felix Ulrich-PurFluence loss 1cm4DSSD-Tracker800VProton Good      Alu0 deg

Fluence loss measurement 11.12.2021

Start 15:15

0deg =1cm Alu

  310   Sat Dec 11 18:19:56 2021 Felix Ulrich-PurFluence loss 1cm5DSSD-Tracker800VProton Good      Alu0 deg

Fluence loss measurement 11.12.2021

Start 18:17

90deg = all five steps Alu

  312   Sat Oct 8 07:11:03 2022 Christian IrmlerRamon only1RD50-MPW3800 Proton Craplowflux high       