Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 1 of 18  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Data Beam Betatron Beam Chopper Beam Degraderdown Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle Text Attachments
  95   Sat Feb 27 18:56:11 2021 Felix Ulrich-PurWaveforms SiC+Si21SiC+Si+RaMon252.7nominalProton Good  50     Start 13:56

Degrader 50

  
  170   Tue Mar 16 15:10:41 2021 Patrick SiebererPad Sensoren25 252.7nominalProton Good  50   none Start: 14:06
Range Shifter Out, Filter 1 IN, Filter
2 IN
  
  49   Wed Jan 20 17:25:34 2021 Felix Ulrich-PurLowflux p800 commissioning56Ramon+Tracker800  30 spills 10%60%20106dB   MT=1, BSY=50,
1cm off in +x and +y direction
Setting IV
  
  50   Wed Jan 20 17:27:58 2021 Felix Ulrich-PurLowflux p800 commissioning57Ramon+Tracker800  30 spills 10%60%20106dB   MT=1, BSY=50,
2cm off in +x and +y direction (wrong
direction)
  
  51   Wed Jan 20 17:28:56 2021 Felix Ulrich-PurLowflux p800 commissioning58Ramon+Tracker800  30 spills 10%60%20106dB   MT=1, BSY=50,
looks +0.5vcm x, -0.5cm y
rate quite low
  
  52   Wed Jan 20 17:29:42 2021 Felix Ulrich-PurLowflux p800 commissioning59Ramon+Tracker800  30 spills 10%60%20106dB   MT=1, BSY=50,
x is centered now, y looks 0.25cm
off
  
  53   Wed Jan 20 17:30:17 2021 Felix Ulrich-PurLowflux p800 commissioning60Ramon+Tracker800  30 spills 10%60%20106dB   MT=1, BSY=50,
rate few 100Hz
x looks off, y centered now (after
  
  55   Wed Jan 20 17:31:30 2021 Felix Ulrich-PurLowflux p800 commissioning63Ramon+Tracker800  30 spills 10%60%20106dB   MT=1, BSY=50,
beam almost centered (total correction
+15mm x (to the left in beam direction) and
  
  56   Wed Jan 20 17:33:58 2021 Felix Ulrich-PurLowflux p800 commissioning64Ramon+Tracker800  30 spills 10%60%20106dB   MT=1, BSY=50,
beam  centered (total correction
+12.5mm x (to the left in beam direction)
  
  57   Wed Jan 20 17:35:25 2021 Felix Ulrich-PurLowflux p800 commissioning62Ramon+Tracker800  30 spills 10%60%20106dB   MT=1, BSY=50,
now correct degrader, beam still off
setting IV
  
  58   Wed Jan 20 17:35:51 2021 Felix Ulrich-PurLowflux p800 commissioning66Ramon+Tracker800  30 spills 10%62%20106dB   MT=1, BSY=50,
beam is centered
rate few 100kHz and two peaks in beam
  
  59   Wed Jan 20 17:36:21 2021 Felix Ulrich-PurLowflux p800 commissioning65Ramon+Tracker800  30 spills 10%80%20106dB   MT=1, BSY=50,
beam shifted again
jumps in rate too high
  
  60   Wed Jan 20 17:41:27 2021 Felix Ulrich-PurLowflux p800 commissioning67Ramon+Tracker800  30 spills 10%60.5%20106dB   MT=1, BSY=50,
beam shifted again
max 30kHz, low rate
  
  61   Wed Jan 20 17:42:02 2021 Felix Ulrich-PurLowflux p800 commissioning68Ramon+Tracker800  30 spills 11%60%20106dB   MT=1, BSY=50,
setting IV
 
  
  62   Wed Jan 20 17:42:31 2021 Felix Ulrich-PurLowflux p800 commissioning69Ramon+Tracker800  30 spills 11%60.5%20106dB   MT=1, BSY=50,
setting IV
 
  
  63   Wed Jan 20 17:42:38 2021 Felix Ulrich-PurLowflux p800 commissioning71Ramon+Tracker800  30 spills 11%60.25%20106dB   MT=1, BSY=50,
setting IV
 
  
  64   Wed Jan 20 17:44:19 2021 Felix Ulrich-PurLowflux p800 commissioning73Ramon+Tracker800  30 spills 100%60.5%20106dB   MT=1, BSY=50,
setting V

spot still centered
  
  65   Wed Jan 20 17:46:32 2021 Felix Ulrich-PurLowflux p800 commissioning74Ramon+Tracker800  30 spills 11%60.5%20306dB   MT=1, BSY=50,
potential setting VI

few outlier, fewer fluctuations
  
  66   Wed Jan 20 17:47:24 2021 Felix Ulrich-PurLowflux p800 commissioning75Ramon+Tracker800  30 spills 12%60.5%20306dB   MT=1, BSY=50,
setting VI

few outlier, fewer fluctuations
  
  67   Wed Jan 20 17:47:53 2021 Felix Ulrich-PurLowflux p800 commissioning76Ramon+Tracker800  30 spills 100%60.5%20306dB   MT=1, BSY=50,

beam off
potential setting VII
  
ELOG V3.1.5-fc6679b