ID |
Date |
Author |
Subject |
Run Number |
DUT |
Beam Energy |
Rate Setting |
Particle Type |
Events |
Data |
Beam Betatron |
Beam Chopper |
Beam Degrader |
Beam EFE |
Beam Orb |
Beam QuadScan |
PhantomType |
PhantomAngle |
161
|
Tue Mar 16 15:05:08 2021 |
Patrick Sieberer | Pad Sensoren | 16 | | 100.4 | II(BETA+EFE) | Proton | | Good | | | | | | | none | |
Start: 11:38
Range Shifter Out, Filter 1 IN, Filter 2 IN |
162
|
Tue Mar 16 15:05:24 2021 |
Patrick Sieberer | Pad Sensoren | 17 | | 194.3 | II(BETA+EFE) | Proton | | Good | | | | | | | none | |
Start: 11:46
Range Shifter Out, Filter 1 IN, Filter 2 IN |
163
|
Tue Mar 16 15:05:40 2021 |
Patrick Sieberer | Pad Sensoren | 18 | | 252.7 | II(BETA+EFE) | Proton | | Good | | | | | | | none | |
Start: 11:57
Range Shifter Out, Filter 1 IN, Filter 2 IN
Lost beam at 12:15 |
164
|
Tue Mar 16 15:06:13 2021 |
Patrick Sieberer | Pad Sensoren | 19 | | 252.7 | II(BETA+EFE) | Proton | | Good | | | | | | | none | |
Start: 12:18
Range Shifter Out, Filter 1 IN, Filter 2 IN
Restart run with same settings |
165
|
Tue Mar 16 15:07:06 2021 |
Patrick Sieberer | Pad Sensoren | 20 | | 100.4 | I(EFE+SID0) | Proton | | Good | | | | | | | none | |
Start: 12:25
Range Shifter Out, Filter 1 IN, Filter 2 IN
Changed compliance of both sensors to 100 uA |
166
|
Tue Mar 16 15:07:56 2021 |
Patrick Sieberer | Pad Sensoren | 21 | | 100.4 | III(EFE+SID2) | Proton | | Good | | | | | | | none | |
Start: 12:41
Range Shifter Out, Filter 1 IN, Filter 2 IN
12:53 went inside to test if sensors are activated |
167
|
Tue Mar 16 15:09:04 2021 |
Patrick Sieberer | Pad Sensoren | 22 | | 800 | V | Proton | | Good | | | | | | | none | |
Start: 13:09
Range Shifter Out, Filter 1 IN, Filter 2 IN
Changed compliance values back to 30 uA |
168
|
Tue Mar 16 15:09:33 2021 |
Patrick Sieberer | Pad Sensoren | 23 | | 800 | VII | Proton | | Good | | | | | | | none | |
Start: 13:36
Range Shifter Out, Filter 1 IN, Filter 2 IN |
169
|
Tue Mar 16 15:10:11 2021 |
Patrick Sieberer | Pad Sensoren | 24 | | 252.7 | nominal | Proton | | Good | | | 10 | | | | none | |
Start: 13:57
Range Shifter Out, Filter 1 IN, Filter 2 IN |
170
|
Tue Mar 16 15:10:41 2021 |
Patrick Sieberer | Pad Sensoren | 25 | | 252.7 | nominal | Proton | | Good | | | 50 | | | | none | |
Start: 14:06
Range Shifter Out, Filter 1 IN, Filter 2 IN |
171
|
Tue Mar 16 15:11:00 2021 |
Patrick Sieberer | Pad Sensoren | 26 | | 252.7 | nominal | Proton | | Good | | | 100 | | | | none | |
Start: 14:20
Range Shifter Out, Filter 1 IN, Filter 2 IN |
172
|
Tue Mar 16 15:11:34 2021 |
Patrick Sieberer | Pad Sensoren | 27 | | 252.7 | nominal | Proton | | Good | | | 100 | | | | none | |
Start: 14:28
Range Shifter Out, Filter 1 IN, Filter 2 IN
Power supply of si-sensor went into compliance, therefore the compliance value was set to 100 uA again
Ende 14:35 |
173
|
Tue Mar 16 15:12:04 2021 |
Patrick Sieberer | MPW2 Analog output | 10 | MPW2+Picoscope | 252.7 | I(EFE+SID0) | Proton | | Crap | | | | | | | | |
3er Koinzidenz
Pix 06, 33, 34 |
174
|
Tue Mar 16 15:13:34 2021 |
Patrick Sieberer | MPW2 Analog output | 11 | MPW2+Picoscope | 252.7 | I(EFE+SID0) | Proton | | Good | | | | | | | | |
3er Koinzidenz
Pix 06, 33, 34 |
175
|
Tue Mar 16 15:13:58 2021 |
Patrick Sieberer | MPW2 Analog output | 12 | MPW2+Picoscope | 252.7 | I(EFE+SID0) | Proton | | Good | | | | | | | | |
2er Koinzidenz
Pix 06, 33, 34
Ratenmessunge fuer spaeteres Tracking |
176
|
Tue Mar 16 15:14:28 2021 |
Patrick Sieberer | MPW2 Analog output | 13 | MPW2+Picoscope | 83 | I(EFE+SID0) | Proton | | Good | | | | | | | | |
3er Koinzidenz
Pix 06, 33, 34 |
177
|
Tue Mar 16 15:15:12 2021 |
Patrick Sieberer | MPW2 Analog output | 14 | MPW2+Picoscope | 252.7 | I(EFE+SID0) | Proton | | Good | | | | | | | | |
3er Koinzidenz
Pix 06, 33, 34
retry for Run 11 (wrong picodata format) |
178
|
Tue Mar 16 15:16:01 2021 |
Patrick Sieberer | MPW2 Analog output | 15 | MPW2+Picoscope | 62.4 | I(EFE+SID0) | Proton | | Good | | | | | | | | |
3er Koinzidenz
Pix 06, 33, 34 |
179
|
Tue Mar 16 15:16:24 2021 |
Patrick Sieberer | MPW2 Analog output | 16 | MPW2+Picoscope | 175.3 | I(EFE+SID0) | Proton | | Good | | | | | | | | |
3er Koinzidenz
Pix 06, 33, 34 |
180
|
Tue Mar 16 15:16:38 2021 |
Patrick Sieberer | MPW2 Analog output | 17 | MPW2+Picoscope | 800 | VII | Proton | | Good | | | | | | | | |
3er Koinzidenz
Pix 06, 33, 34 |