  136   Tue Mar 2 15:53:25 2021 Patrick SiebererMPW2 Tracking99MPW2+tracker252.7I(EFE+SID0)Proton30kGood        

Start 04:09
TRACKER WINDOW
Threshold MPW2: 960mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 25
3 Koinzidenz TLU und Hybrid Modus (2er und 3er Koinzidenz) am MPW

zs_cut geaendert zu 5
 

  137   Tue Mar 2 15:54:04 2021 Patrick SiebererMPW2 Analog output100MPW2+Picoscope252.7I(EFE+SID0)Proton0Crap        

Setting switched to analog curve forms (CaR Board ADC + picoscope) - first 2 tracker planes moved outside beam
Threshold MPW2: 960mV, Pixel R3 C3
3 Koinzidenz TLU und Hybrid Modus (2er und 3er Koinzidenz) am MPW

Crap run, MPW did not send data
 

  138   Tue Mar 2 15:57:00 2021 Patrick SiebererMPW2 Analog output101MPW2+Picoscope252.7I(EFE+SID0)Proton0Crap        

Threshold MPW2: 960mV, Pixel R3 C3
2 Koinzidenz, for testing beam

  139   Tue Mar 2 15:58:35 2021 Patrick SiebererMPW2 Analog output102MPW2+Picoscope252.7I(EFE+SID0)Proton1kGood        

MPW2 ANALOG
Threshold MPW2: 960mV, Pixel R3 C3, Pixel R3 C4, Pixel R0 C1. Pixel R0 C6
3 Koinzidenz TLU und Hybrid Modus (2er und 3er Koinzidenz) am MPW

1k ADC curves per pixel
 

  148   Tue Mar 16 14:54:40 2021 Patrick SiebererPad Sensoren3 252.7III(EFE+SID2)Proton Good      none 

Start: 07:00
Range Shifter Out, Filter 1 IN, Filter 2 IN
Scintillators in front

  149   Tue Mar 16 14:55:06 2021 Patrick SiebererPad Sensoren4 252.7III(EFE+SID2)Proton Good      none 

Start: 07:30
Range Shifter Out, Filter 1 IN, Filter 2 IN
Before the run we went inside to: put scintillators behind the sensors, reset the fpga counters

  158   Tue Mar 16 15:03:23 2021 Patrick SiebererPad Sensoren13 252.7I(EFE+SID0)Proton Good      none 

Start: 10:31
Range Shifter Out, Filter 1 IN, Filter 2 IN
10:57 went inside to restart the Trenz NUC PC + FPGA

  163   Tue Mar 16 15:05:40 2021 Patrick SiebererPad Sensoren18 252.7II(BETA+EFE)Proton Good      none 

Start: 11:57
Range Shifter Out, Filter 1 IN, Filter 2 IN
Lost beam at 12:15

  164   Tue Mar 16 15:06:13 2021 Patrick SiebererPad Sensoren19 252.7II(BETA+EFE)Proton Good      none 

Start: 12:18
Range Shifter Out, Filter 1 IN, Filter 2 IN
Restart run with same settings

  169   Tue Mar 16 15:10:11 2021 Patrick SiebererPad Sensoren24 252.7nominalProton Good  10   none 

Start: 13:57
Range Shifter Out, Filter 1 IN, Filter 2 IN

  170   Tue Mar 16 15:10:41 2021 Patrick SiebererPad Sensoren25 252.7nominalProton Good  50   none 

Start: 14:06
Range Shifter Out, Filter 1 IN, Filter 2 IN

  171   Tue Mar 16 15:11:00 2021 Patrick SiebererPad Sensoren26 252.7nominalProton Good  100   none 

Start: 14:20
Range Shifter Out, Filter 1 IN, Filter 2 IN

  172   Tue Mar 16 15:11:34 2021 Patrick SiebererPad Sensoren27 252.7nominalProton Good  100   none 

Start: 14:28
Range Shifter Out, Filter 1 IN, Filter 2 IN
Power supply of si-sensor went into compliance, therefore the compliance value was set to 100 uA again
Ende 14:35

  173   Tue Mar 16 15:12:04 2021 Patrick SiebererMPW2 Analog output10MPW2+Picoscope252.7I(EFE+SID0)Proton Crap        

3er Koinzidenz
Pix 06, 33, 34

  174   Tue Mar 16 15:13:34 2021 Patrick SiebererMPW2 Analog output11MPW2+Picoscope252.7I(EFE+SID0)Proton Good        

3er Koinzidenz
Pix 06, 33, 34

  175   Tue Mar 16 15:13:58 2021 Patrick SiebererMPW2 Analog output12MPW2+Picoscope252.7I(EFE+SID0)Proton Good        

2er Koinzidenz
Pix 06, 33, 34
Ratenmessunge fuer spaeteres Tracking

  177   Tue Mar 16 15:15:12 2021 Patrick SiebererMPW2 Analog output14MPW2+Picoscope252.7I(EFE+SID0)Proton Good        

3er Koinzidenz
Pix 06, 33, 34
retry for Run 11 (wrong picodata format)

  184   Tue Mar 16 15:18:12 2021 Patrick SiebererMPW2 Analog output20MPW2+Picoscope252.7I(EFE+SID0)Proton Crap        

3er Koinzidenz
for Beam

  185   Tue Mar 16 15:18:23 2021 Patrick SiebererMPW2 Analog output21MPW2+Picoscope252.7I(EFE+SID0)Proton Crap        

3er Koinzidenz
for Beam

  186   Tue Mar 16 15:18:31 2021 Patrick SiebererMPW2 Analog output22MPW2+Picoscope252.7I(EFE+SID0)Proton Crap        

3er Koinzidenz
for Beam