Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025
  MedAustron 2021, Page 9 of 18  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Datadown Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle
  176   Tue Mar 16 15:14:28 2021 Patrick SiebererMPW2 Analog output13MPW2+Picoscope83I(EFE+SID0)Proton Good        

3er Koinzidenz
Pix 06, 33, 34

  177   Tue Mar 16 15:15:12 2021 Patrick SiebererMPW2 Analog output14MPW2+Picoscope252.7I(EFE+SID0)Proton Good        

3er Koinzidenz
Pix 06, 33, 34
retry for Run 11 (wrong picodata format)

  178   Tue Mar 16 15:16:01 2021 Patrick SiebererMPW2 Analog output15MPW2+Picoscope62.4I(EFE+SID0)Proton Good        

3er Koinzidenz
Pix 06, 33, 34

  179   Tue Mar 16 15:16:24 2021 Patrick SiebererMPW2 Analog output16MPW2+Picoscope175.3I(EFE+SID0)Proton Good        

3er Koinzidenz
Pix 06, 33, 34

  180   Tue Mar 16 15:16:38 2021 Patrick SiebererMPW2 Analog output17MPW2+Picoscope800VIIProton Good        

3er Koinzidenz
Pix 06, 33, 34

  189   Tue Mar 16 15:20:11 2021 Patrick SiebererMPW2 Tracking52MPW2+tracker252.7I(EFE+SID0)Proton Good        

2er Koinzidenz
Row 3 Col 4
Trigger-Busy: 23, Max Trigger 100 -> Gute Settings!

  191   Tue Mar 16 15:22:01 2021 Patrick SiebererMPW2 Tracking54MPW2+tracker252.7I(EFE+SID0)Proton Good        

2er Koinzidenz
Row 3 Col 4
Neues Beam Files -> Rate nun richtig.

  192   Tue Mar 16 15:23:04 2021 Patrick SiebererMPW2 Tracking55MPW2+tracker252.7I(EFE+SID0)Proton Good        

2er Koinzidenz
Row 3 Col 4
Trigger-Busy: 23, Max Trigger geaendert

  193   Tue Mar 16 15:23:49 2021 Patrick SiebererMPW2 Tracking56MPW2+tracker252.7I(EFE+SID0)Proton Good        

2er Koinzidenz
Row 3 Col 4
Trigger-Busy: 25, Max Trigger:50

  194   Tue Mar 16 15:24:34 2021 Patrick SiebererMPW2 Tracking57MPW2+tracker252.7I(EFE+SID0)Proton Good        

2er Koinzidenz
Row 3 Col 4
Trigger-Busy + Max Trigger unkown, check in log-file

  195   Tue Mar 16 15:24:53 2021 Patrick SiebererMPW2 Tracking58MPW2+tracker252.7I(EFE+SID0)Proton Good        

2er Koinzidenz
Row 3 Col 4
Trigger-Busy + Max Trigger unkown, check in log-file

  196   Tue Mar 16 15:25:00 2021 Patrick SiebererMPW2 Tracking59MPW2+tracker252.7I(EFE+SID0)Proton Good        

2er Koinzidenz
Row 3 Col 4
Trigger-Busy + Max Trigger unkown, check in log-file

  197   Tue Mar 16 15:25:29 2021 Patrick SiebererMPW2 Tracking60MPW2+tracker252.7I(EFE+SID0)Proton Good        

3er Koinzidenz
Row 3 Col 4
WINDOW RUN
Trigger-Busy + Max Trigger unkown, check in log-file

  200   Tue Mar 16 15:27:14 2021 Patrick SiebererMPW2 Tracking63Ramon+Tracker252.7I(EFE+SID0)Proton Good        

2er Koinzidenz
Tracker only, ALIGNMENT
Danach: Umbau auf SiC (Junctionboard geaendert) fuer SiC Alignment

  202   Tue Mar 16 15:29:14 2021 Patrick SiebererSiC strip sensor65Ramon+Tracker252.7I(EFE+SID0)Proton Good        

2er Koinzidenz
Alignment Run SiC
23:21

  204   Tue Mar 16 15:31:06 2021 Patrick SiebererSiC strip sensor67SiC+DSSD tracker62.4II(BETA+EFE)Proton Good        

Energy Scan SiC Sensor
23:37
30.000 Hz, falsche Rate -> Filter

  207   Tue Mar 16 15:33:23 2021 Patrick SiebererSiC strip sensor70SiC+DSSD tracker62.4II(BETA+EFE)Proton1.1MGood        

Energy Scan
00:21
Filter vermutlich draussen

  208   Tue Mar 16 15:34:25 2021 Patrick SiebererSiC strip sensor71SiC+DSSD tracker100.4II(BETA+EFE)Proton1.2MGood        

Energy Scan
00:46
Filter vermutlich draussen

  209   Tue Mar 16 15:34:50 2021 Patrick SiebererSiC strip sensor72SiC+DSSD tracker83II(BETA+EFE)Proton1.2MGood        

Energy Scan
01:10
Filter vermutlich draussen

  210   Tue Mar 16 15:35:10 2021 Patrick SiebererSiC strip sensor73SiC+DSSD tracker145.4II(BETA+EFE)Proton1MGood        

Energy Scan
01:35
Filter vermutlich draussen

ELOG V3.1.5-fc6679b