Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 8 of 18  Not logged in ELOG logo
Entry  Thu Oct 7 11:13:21 2021, Philipp Gaggl, Pad Sensoren, 37, SiC+Si, 62.4, , Proton, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V

Entry  Thu Oct 7 11:13:46 2021, Philipp Gaggl, Pad Sensoren, 38, SiC+Si, , , , , Unknown, , , , , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V
Noise measurement

Entry  Wed May 12 08:53:15 2021, Felix Ulrich-Pur, PMMA 90deg, 10, Drehtisch, 145.4, II(BETA+EFE), Proton, , Good, , , , , , , PMMA, 90 

TB 24.4.21

90deg (0.2-1cm PMMA)

Entry  Wed May 12 08:53:46 2021, Felix Ulrich-Pur, PMMA 90deg, 11, Drehtisch, 100.4, II(BETA+EFE), Proton, , Good, , , , , , , PMMA, 90 

TB 24.4.21

90deg (0.2-1cm PMMA)

Entry  Wed May 12 08:52:05 2021, Felix Ulrich-Pur, PMMA 0deg, 9, Drehtisch, 145.4, II(BETA+EFE), Proton, , Good, , , , , , , PMMA, 0 

TB 24.4.21

0deg (1cm PMMA)

timing was adjusted and FADC had to be restarted

Entry  Wed May 12 08:54:54 2021, Felix Ulrich-Pur, PMMA 0deg, 12, Drehtisch, 100.4, II(BETA+EFE), Proton, , Good, , , , , , , PMMA, 0 

TB 24.4.21

0deg (1cm PMMA)

Entry  Tue Mar 2 14:42:56 2021, Patrick Sieberer, MPW2 Tracking, 75, MPW2+tracker, 252.7, I(EFE+SID0), Proton, , Crap, , , , , , , ,  

Start xx:xx:

Tracker speed test: 2MHz internal Trigger from TLU -> works.

Entry  Tue Mar 2 14:45:04 2021, Patrick Sieberer, MPW2 Tracking, 76, MPW2+tracker, 252.7, I(EFE+SID0), Proton, , Crap, , , , , , , ,  

Start xx:xx:

Tracker speed test: 4MHz internal Trigger from TLU -> works.
Tracker Setting: max_trigger=1 and trigger_busy=25. This gives ~20kHz eventrate.

Entry  Tue Mar 2 14:46:49 2021, Patrick Sieberer, MPW2 Tracking, 77-82, MPW2+tracker, 252.7, I(EFE+SID0), Proton, , Crap, , , , , , , ,  

Start 22:23 (Run79), 22:30, 22:37, 22:43 

Synchronization: Playing around with trgger_busy (range 25-500) This slows down Eventrate, but does not solve our issue of not being able to count all overflows. (This depends on the ratio of events hitting the MPW2 only, NOT on the overall busy rate)

Entry  Tue Mar 2 15:30:11 2021, Patrick Sieberer, MPW2 Tracking, 83, MPW2+tracker, 252.7, I(EFE+SID0), Proton, 100k, Crap, , , , , , , ,  

Start 22:55
Threshold MPW2: 960mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 25
3 Koinzidenz TLU und 3er Koinzidenz Messung am MPW

Entry  Tue Mar 2 15:32:52 2021, Patrick Sieberer, MPW2 Tracking, 84, MPW2+tracker, 252.7, I(EFE+SID0), Proton, 30k, Crap, , , , , , , ,  

Start 23:21
Threshold MPW2: 960mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 500
2 Koinzidenz TLU und 2er Koinzidenz Messmodus am MPW
Conclusion: Slowing down Tracker does not help (seen before)

Entry  Tue Mar 2 15:34:49 2021, Patrick Sieberer, MPW2 Tracking, 85, MPW2+tracker, 252.7, I(EFE+SID0), Proton, 640k, Unknown, , , , , , , ,  

Start 23:24
Threshold MPW2: 960mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 500
2 Koinzidenz TLU und 3er Koinzidenz Messmodus am MPW

Entry  Tue Mar 2 15:39:24 2021, Patrick Sieberer, MPW2 Tracking, 86, MPW2+tracker, 252.7, I(EFE+SID0), Proton, 46k, Unknown, , , , , , , ,  

Start 23:43
Threshold MPW2: 960mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 500
2 Koinzidenz TLU und 3er Koinzidenz Messmodus am MPW

Entry  Tue Mar 2 15:40:01 2021, Patrick Sieberer, MPW2 Tracking, 87, MPW2+tracker, 252.7, I(EFE+SID0), Proton, , Good, , , , , , , ,  

Start 23:44
Threshold MPW2: 960mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 500
3 Koinzidenz TLU und 3er Koinzidenz Messmodus am MPW

testing for picoscope

Entry  Tue Mar 2 15:41:09 2021, Patrick Sieberer, MPW2 Tracking, 88, MPW2+tracker, 252.7, I(EFE+SID0), Proton, , Good, , , , , , , ,  

Start 23:54
Threshold MPW2: 1200mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 500
3 Koinzidenz TLU und 3er Koinzidenz Messmodus am MPW

testing for picoscope

Entry  Tue Mar 2 15:42:11 2021, Patrick Sieberer, MPW2 Tracking, 89, MPW2+tracker, 252.7, I(EFE+SID0), Proton, 1.8M, Unknown, , , , , , , ,  

Start 23:56
Threshold MPW2: 1200mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 500
2 Koinzidenz TLU und 3er Koinzidenz Messmodus am MPW

Entry  Tue Mar 2 15:43:01 2021, Patrick Sieberer, MPW2 Tracking, 90, MPW2+tracker, 252.7, I(EFE+SID0), Proton, 300k, Crap, , , , , , , ,  

Start 00:34
Threshold MPW2: 960mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 500
2 Koinzidenz TLU und 3er Koinzidenz Messmodus am MPW
Testen neue Software: Triggernummer von 2er Koinzidenz modus, Daten von 3er Koinzidenz modus
Forgot to restart Producer

Entry  Tue Mar 2 15:44:51 2021, Patrick Sieberer, MPW2 Tracking, 91, MPW2+tracker, 252.7, I(EFE+SID0), Proton, 235k, Good, , , , , , , ,  

Start 00:41
Threshold MPW2: 960mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 500
2 Koinzidenz TLU und Hybrid Modus (2er und 3er Koinzidenz) am MPW
Producer restartet -> works

Entry  Tue Mar 2 15:46:21 2021, Patrick Sieberer, MPW2 Tracking, 92, MPW2+tracker, 252.7, I(EFE+SID0), Proton, 235k, Good, , , , , , , ,  

Start 00:xx
Threshold MPW2: 960mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 500
2 Koinzidenz TLU und Hybrid Modus (2er und 3er Koinzidenz) am MPW
Fill Level der MPW Fifos von 5 auf 1 geaendert

Entry  Tue Mar 2 15:47:32 2021, Patrick Sieberer, MPW2 Tracking, 93, MPW2+tracker, 252.7, I(EFE+SID0), Proton, , Crap, , , , , , , ,  

Start 00:xx
Threshold MPW2: 960mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 500
2 Koinzidenz TLU und Hybrid Modus (2er und 3er Koinzidenz) am MPW
Davor: Neue local runs am Tracker (...TLU_92.xml) -> Ab hier verwendet
Run for testing beam only

ELOG V3.1.5-fc6679b