Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 7 of 18  Not logged in ELOG logo
ID Date Author Subject Run Numberdown DUT Beam Energy Rate Setting Particle Type Events Data Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle
  189   Tue Mar 16 15:20:11 2021 Patrick SiebererMPW2 Tracking52MPW2+tracker252.7I(EFE+SID0)Proton Good        

2er Koinzidenz
Row 3 Col 4
Trigger-Busy: 23, Max Trigger 100 -> Gute Settings!

  42   Sun Jan 10 07:32:11 2021 Maximilian TomaschekLowflux recommissioning51Ramon+Tracker145.4  40 spills 350k eventsGood10% 101 2  

Spotsize

  188   Tue Mar 16 15:19:44 2021 Patrick SiebererMPW2 Tracking51MPW2+tracker252.7I(EFE+SID0)Proton Crap        

2er Koinzidenz
Row 3 Col 4
test, neue Beam Data: CPD Data neu geladen

  98   Sat Feb 27 19:06:07 2021 Felix Ulrich-PurLocal Runs DSSDs+SiC50-56SiC+DSSD trackerNoisenominal  Good        

Start 16:15:
Final MT=1, final BSY length =500 (2kHz)

  41   Sun Jan 10 07:32:00 2021 Maximilian TomaschekLowflux recommissioning50Ramon+Tracker175.3  40 spills 350k eventsGood10% 101 2  

Spotsize

  187   Tue Mar 16 15:18:45 2021 Patrick SiebererMPW2 Tracking50MPW2+tracker252.7I(EFE+SID0)Proton Crap        

2er Koinzidenz
Row 3 Col 4
test

  4   Sun Jan 10 06:33:44 2021 Maximilian TomaschekLowflux recommissioning5Ramon+Tracker100.4  30 spills 10% 101    

Rate

  79   Sat Feb 27 09:30:32 2021 Felix Ulrich-PurRate verification5SiC+Si+RaMon62.4III(EFE+SID2)  Good        

Start 07:03
verified if run 1 was reliable-->Same results

 

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x: 0
y: 0 

  150   Tue Mar 16 14:55:52 2021 Patrick SiebererPad Sensoren5 194.3III(EFE+SID2)Proton Good      none 

Start: 07:38
Range Shifter Out, Filter 1 IN, Filter 2 IN
Scintillators in front
 

  219   Wed May 12 08:50:46 2021 Felix Ulrich-PurAlu 90deg5Drehtisch145.4II(BETA+EFE)Proton Good      Alu90

TB 24.4.21

90deg (0.2-1cmAlu)

  231   Sun Jun 20 19:35:46 2021 Felix Ulrich-PurHADES energy run5HADES-LGADs194.3I(EFE+SID0)Proton Good      none0

TB 19.6.21

Start 17:42
Mean rate O(MHz)
 

  277   Sun Nov 7 18:53:46 2021 Felix Ulrich-PurLow flux test 7.11.215 145.4I(EFE+SID0) 30 spillsGood      none 

Start: 07:01 O(MHz)

  310   Sat Dec 11 18:19:56 2021 Felix Ulrich-PurFluence loss 1cm5DSSD-Tracker800VProton Good      Alu0 deg

Fluence loss measurement 11.12.2021

Start 18:17

90deg = all five steps Alu

  316   Sat Oct 8 07:40:51 2022 Christian Irmlerramon + tracker + DUT5RD50-MPW3800  24260338Goodlowflux high       

Tracker latency lat=42

First data run w/ ramon + tracker + MPW3 + monitor connected

Tracker dropped some udp packages, total tracker events 23166448

  40   Sun Jan 10 07:30:58 2021 Maximilian TomaschekLowflux recommissioning49Ramon+Tracker194.3  40 spills 350k eventsGood10% 101 2  

Spotsize

  39   Sun Jan 10 07:29:09 2021 Maximilian TomaschekLowflux recommissioning48Ramon+Tracker252.7  40 spills 250k eventsGood10% 101 2  

Spotsize

  38   Sun Jan 10 07:27:55 2021 Maximilian TomaschekLowflux recommissioning47Ramon+Tracker62.4  7 spills 1e6 eventsGood  101 0  

Spotsize, max T 1 & BSY 50 -> rate zu hoch

  37   Sun Jan 10 07:27:37 2021 Maximilian TomaschekLowflux recommissioning45Ramon+Tracker83  7 spills 1e6 eventsGood  101 0  

Spotsize

  351   Sat Oct 8 13:27:10 2022 Patrick Siebererramon + tracker + DUT41RD50-MPW3252.7   Unknownlowflux high       

ASIC: TH 1320, noisy pixel masekd
BEAM OFF

send to monitor: 10

 

 

 

 

 

  36   Sun Jan 10 07:26:58 2021 Maximilian TomaschekLowflux recommissioning40Ramon+Tracker100.4  7 spills 1e6 eventsGood  101 0  

Spotsize

ELOG V3.1.5-fc6679b