ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Data Beam Betatrondown Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle
  18   Sun Jan 10 07:03:56 2021 Maximilian TomaschekLowflux recommissioning20Ramon+Tracker175.3  30 spillsGood  101 0  

Rate, Beta nominal

  19   Sun Jan 10 07:04:21 2021 Maximilian TomaschekLowflux recommissioning21Ramon+Tracker145.4  15 spillsGood  101 0  

Rate, Beta nominal

  20   Sun Jan 10 07:05:52 2021 Maximilian TomaschekLowflux recommissioning23Ramon+Tracker100.4  30 spillsCrap  101 0  

Rate, Beta nominal, suddenly no tracker events

  21   Sun Jan 10 07:14:54 2021 Maximilian TomaschekLowflux recommissioning24Ramon+Tracker83  30 spillsCrap  101 0  

Rate, Beta nominal, no tracker data

  22   Sun Jan 10 07:17:44 2021 Maximilian TomaschekLowflux recommissioning25Ramon+Tracker62.4  30 spillsCrap  101 0  

Rate, Beta nominal, no tracker data

  23   Sun Jan 10 07:18:16 2021 Maximilian TomaschekLowflux recommissioning26Ramon+Tracker   30 spillsGood        

Spotsize test, nach power cycle

  24   Sun Jan 10 07:19:03 2021 Maximilian TomaschekLowflux recommissioning27Ramon+Tracker   30 spillsGood        

Spotsize test, nach power cycle

  32   Sun Jan 10 07:24:46 2021 Maximilian TomaschekLowflux recommissioning36Ramon+Tracker252.7  7 spills 1e6 eventsGood  101 0  

Spotsize

  33   Sun Jan 10 07:26:16 2021 Maximilian TomaschekLowflux recommissioning37Ramon+Tracker194.3  7 spills 1e6 eventsGood  101 0  

Spotsize

  34   Sun Jan 10 07:26:31 2021 Maximilian TomaschekLowflux recommissioning38Ramon+Tracker175.3  7 spills 1e6 eventsGood  101 0  

Spotsize

  35   Sun Jan 10 07:26:42 2021 Maximilian TomaschekLowflux recommissioning39Ramon+Tracker145.4  7 spills 1e6 eventsGood  101 0  

Spotsize

  36   Sun Jan 10 07:26:58 2021 Maximilian TomaschekLowflux recommissioning40Ramon+Tracker100.4  7 spills 1e6 eventsGood  101 0  

Spotsize

  37   Sun Jan 10 07:27:37 2021 Maximilian TomaschekLowflux recommissioning45Ramon+Tracker83  7 spills 1e6 eventsGood  101 0  

Spotsize

  38   Sun Jan 10 07:27:55 2021 Maximilian TomaschekLowflux recommissioning47Ramon+Tracker62.4  7 spills 1e6 eventsGood  101 0  

Spotsize, max T 1 & BSY 50 -> rate zu hoch

  46   Sun Jan 10 07:33:19 2021 Maximilian TomaschekLowflux recommissioning55Peakfinder252.7  40 spills 350k eventsGood  101 0  

fail MAPTA Sensor, not trigger, only signal with 5s spill 5s pause (spill over time meas), looked similar

  76   Sat Feb 27 09:26:27 2021 Felix Ulrich-PurRate verification1SiC+Si+RaMon62.4III(EFE+SID2)  Unknown        

Start 06:37
rate looks okish. few emtpy spills

 

2021-02-27, 06:07:

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.112V channel 1, 0-Level: 2.315V channel 1

position:

x: 0
y: 0 

2021-02-27, 06:30:

Referenz: 2.477V channel 1
channel 2 unverändert
 

2021-02-27, 06:37:

Setting: 3 

Run 1: 6:37 62.4 MeV, Rate geringer als erwartet 

 

  77   Sat Feb 27 09:28:07 2021 Felix Ulrich-PurRate verification2SiC+Si+RaMon252.7III(EFE+SID2)  Crap        

Start 06:47
rate only 10Hz, stopped run, room request and rewired trigger.

NOTE: Problem was caused by operators: Optics were not set correctly after ramping up energy from 62.4 to 252.7, not trigger cable

 

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x: 0
y: 0 

  78   Sat Feb 27 09:29:41 2021 Felix Ulrich-PurRate verification4SiC+Si+RaMon252.7III(EFE+SID2)  Good        

Start 06:55
reallocated correctly, rate looks similar to old measurements now (kHz ish)

 

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x: 0
y: 0 

  79   Sat Feb 27 09:30:32 2021 Felix Ulrich-PurRate verification5SiC+Si+RaMon62.4III(EFE+SID2)  Good        

Start 07:03
verified if run 1 was reliable-->Same results

 

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x: 0
y: 0 

  80   Sat Feb 27 09:31:57 2021 Felix Ulrich-PurRate verification6SiC+Si+RaMon252.7I(EFE+SID0)  Good        

Start 07:16
rate looks fine,

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x: 0
y: 0 

SiC: man sieht erstmals Signale 

ELOG V3.1.5-fc6679b