  MedAustron 2021, Page 5 of 18  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Data Beam Betatrondown Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle Text Attachments
  44   Sun Jan 10 07:32:34 2021 Maximilian TomaschekLowflux recommissioning53Ramon+Tracker83  40 spills 350k eventsGood10% 101 2  Spotsize   
  45   Sun Jan 10 07:32:46 2021 Maximilian TomaschekLowflux recommissioning54Ramon+Tracker62.4  40 spills 350k eventsGood10% 101 2  Spotsize   
  47   Wed Jan 20 17:12:15 2021 Felix Ulrich-PurLowflux recommissioning4Ramon+Tracker145.4  30 spills 10% 101    Rate   
  48   Wed Jan 20 17:15:32 2021 Felix Ulrich-PurLowflux recommissioning13Ramon+Tracker145.4  30 spills 10% 101 2  Rate   
  49   Wed Jan 20 17:25:34 2021 Felix Ulrich-PurLowflux p800 commissioning56Ramon+Tracker800  30 spills 10%60%20106dB   MT=1, BSY=50,
1cm off in +x and +y direction
Setting IV
  
  50   Wed Jan 20 17:27:58 2021 Felix Ulrich-PurLowflux p800 commissioning57Ramon+Tracker800  30 spills 10%60%20106dB   MT=1, BSY=50,
2cm off in +x and +y direction (wrong
direction)
  
  51   Wed Jan 20 17:28:56 2021 Felix Ulrich-PurLowflux p800 commissioning58Ramon+Tracker800  30 spills 10%60%20106dB   MT=1, BSY=50,
looks +0.5vcm x, -0.5cm y
rate quite low
  
  52   Wed Jan 20 17:29:42 2021 Felix Ulrich-PurLowflux p800 commissioning59Ramon+Tracker800  30 spills 10%60%20106dB   MT=1, BSY=50,
x is centered now, y looks 0.25cm
off
  
  53   Wed Jan 20 17:30:17 2021 Felix Ulrich-PurLowflux p800 commissioning60Ramon+Tracker800  30 spills 10%60%20106dB   MT=1, BSY=50,
rate few 100Hz
x looks off, y centered now (after
  
  54   Wed Jan 20 17:31:04 2021 Felix Ulrich-PurLowflux p800 commissioning61Ramon+Tracker800  30 spillsCrap10%60%10106dB   wrong degrader setting
setting IV
 
  
  55   Wed Jan 20 17:31:30 2021 Felix Ulrich-PurLowflux p800 commissioning63Ramon+Tracker800  30 spills 10%60%20106dB   MT=1, BSY=50,
beam almost centered (total correction
+15mm x (to the left in beam direction) and
  
  56   Wed Jan 20 17:33:58 2021 Felix Ulrich-PurLowflux p800 commissioning64Ramon+Tracker800  30 spills 10%60%20106dB   MT=1, BSY=50,
beam  centered (total correction
+12.5mm x (to the left in beam direction)
  
  57   Wed Jan 20 17:35:25 2021 Felix Ulrich-PurLowflux p800 commissioning62Ramon+Tracker800  30 spills 10%60%20106dB   MT=1, BSY=50,
now correct degrader, beam still off
setting IV
  
  58   Wed Jan 20 17:35:51 2021 Felix Ulrich-PurLowflux p800 commissioning66Ramon+Tracker800  30 spills 10%62%20106dB   MT=1, BSY=50,
beam is centered
rate few 100kHz and two peaks in beam
  
  59   Wed Jan 20 17:36:21 2021 Felix Ulrich-PurLowflux p800 commissioning65Ramon+Tracker800  30 spills 10%80%20106dB   MT=1, BSY=50,
beam shifted again
jumps in rate too high
  
  60   Wed Jan 20 17:41:27 2021 Felix Ulrich-PurLowflux p800 commissioning67Ramon+Tracker800  30 spills 10%60.5%20106dB   MT=1, BSY=50,
beam shifted again
max 30kHz, low rate
  
  7   Sun Jan 10 06:42:03 2021 Maximilian TomaschekLowflux recommissioning8Ramon+Tracker252.7  30 spills   101 2  Rate, factor 10 too high, role ~30kHz instead
of 3kHz, Beta nominal
  
  8   Sun Jan 10 06:44:59 2021 Maximilian TomaschekLowflux recommissioning9Ramon+Tracker62.4  30 spills   101 2  Rate, Beta nominal, factor 10 too high   
  16   Sun Jan 10 07:01:04 2021 Maximilian TomaschekLowflux recommissioning18Ramon+Tracker252.7  30 spills   101 0  Rate, now Beta nominal again, looks
like old setting 4-6 Mhz
  
  17   Sun Jan 10 07:02:15 2021 Maximilian TomaschekLowflux recommissioning19Ramon+Tracker194.3  30 spillsCrap  101 0  Rate, Beta nominal, ERROR tracker 
-> reset TLU
  