Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 5 of 18  Not logged in ELOG logo
Entry  Sun Nov 7 19:05:15 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 16, , 175.3, nominal, , , Good, , , 10, , , , none,  
Start: 09:38
WET measurement of PMMA slabs also used for TOF-CT (GSI)

1cm PMMA
Entry  Sun Nov 7 19:06:06 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 17, , 175.3, nominal, , , Good, , , 10, , , , none,  
Start: 10:06
WET measurement of PMMA slabs also used for TOF-CT (GSI)

2cm PMMA
Entry  Sun Nov 7 19:06:26 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 18, , 175.3, nominal, , , Good, , , 10, , , , none,  
Start: 10:30
WET measurement of PMMA slabs also used for TOF-CT (GSI)

3cm PMMA
Entry  Sun Nov 7 19:06:40 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 19, , 175.3, nominal, , , Good, , , 10, , , , none,  
Start: 11:00
WET measurement of PMMA slabs also used for TOF-CT (GSI)

4cm PMMA
Entry  Sun Nov 7 19:06:58 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 20, , 175.3, nominal, , , Good, , , 10, , , , none,  
Start: 11:24
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA
Entry  Sun Nov 7 19:07:31 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 21, , 194.3, nominal, , , Good, , , 10, , , , none,  
Start: 11:44
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA. higher energy for Felix Feichtinger
Entry  Sun Nov 7 19:08:47 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 22, , 194.3, nominal, , , Good, , , 10, , , , none,  
Start: 12:00
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA. higher energy for Felix Feichtinger
Entry  Tue Mar 16 14:51:53 2021, Patrick Sieberer, Pad Sensoren, 1, , 62.4, III(EFE+SID2), Proton, , Unknown, , , , , , , none,  
Start: 06:38
Range Shifter Out, Filter 1 IN, Filter 2 IN
Scintillators in front
Entry  Tue Mar 16 14:54:07 2021, Patrick Sieberer, Pad Sensoren, 2, , 145.4, III(EFE+SID2), Proton, , Good, , , , , , , none,  
Start: 06:45
Range Shifter Out, Filter 1 IN, Filter 2 IN
Scintillators in front
Entry  Tue Mar 16 14:54:40 2021, Patrick Sieberer, Pad Sensoren, 3, , 252.7, III(EFE+SID2), Proton, , Good, , , , , , , none,  
Start: 07:00
Range Shifter Out, Filter 1 IN, Filter 2 IN
Scintillators in front 
Entry  Tue Mar 16 14:55:06 2021, Patrick Sieberer, Pad Sensoren, 4, , 252.7, III(EFE+SID2), Proton, , Good, , , , , , , none,  
Start: 07:30
Range Shifter Out, Filter 1 IN, Filter 2 IN
Before the run we went inside to: put scintillators behind the sensors, reset the fpga counters
Entry  Tue Mar 16 14:55:52 2021, Patrick Sieberer, Pad Sensoren, 5, , 194.3, III(EFE+SID2), Proton, , Good, , , , , , , none,  
Start: 07:38
Range Shifter Out, Filter 1 IN, Filter 2 IN
Scintillators in front
Entry  Tue Mar 16 14:56:22 2021, Patrick Sieberer, Pad Sensoren, 6, , 145.4, III(EFE+SID2), Proton, , Good, , , , , , , none,  
Start: 07:42
Range Shifter Out, Filter 1 IN, Filter 2 IN
Entry  Tue Mar 16 14:57:21 2021, Patrick Sieberer, Pad Sensoren, 7, , 62.4, III(EFE+SID2), Proton, , Good, , , , , , , none,  
Start: 07:54
Range Shifter Out, Filter 1 IN, Filter 2 IN
Entry  Tue Mar 16 14:57:41 2021, Patrick Sieberer, Pad Sensoren, 8, , 62.4, I(EFE+SID0), Proton, , Good, , , , , , , none,  
Start: 08:20
Range Shifter Out, Filter 1 IN, Filter 2 IN
Entry  Tue Mar 16 14:58:37 2021, Patrick Sieberer, Pad Sensoren, 9, , 145.4, I(EFE+SID0), Proton, , Good, , , , , , , none,  
Start: 08:34
Range Shifter Out, Filter 1 IN, Filter 2 IN
After that run: Downtime 8:40-10:09
Entry  Tue Mar 16 14:59:18 2021, Patrick Sieberer, Pad Sensoren, 10, , 145.4, I(EFE+SID0), Proton, , Good, , , , , , , none,  
Start: 10:09
Range Shifter Out, Filter 1 IN, Filter 2 IN
Interrupt run at 10:11 -> trying to deactivate filter from the beam room -> didn't work
Entry  Tue Mar 16 15:00:37 2021, Patrick Sieberer, Pad Sensoren, 11, , 145.4, I(EFE+SID0), Proton, , Good, , , , , , , none,  
Start: 10:18
Range Shifter Out, Filter 1 IN, Filter 2 IN
Restarting run with the same settings 
Entry  Tue Mar 16 15:03:04 2021, Patrick Sieberer, Pad Sensoren, 12, , 194.3, I(EFE+SID0), Proton, , Good, , , , , , , none,  
Start: 10:24
Range Shifter Out, Filter 1 IN, Filter 2 IN
Entry  Tue Mar 16 15:03:23 2021, Patrick Sieberer, Pad Sensoren, 13, , 252.7, I(EFE+SID0), Proton, , Good, , , , , , , none,  
Start: 10:31
Range Shifter Out, Filter 1 IN, Filter 2 IN
10:57 went inside to restart the Trenz NUC PC + FPGA
ELOG V3.1.5-fc6679b