New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Subjectdown Run Number DUT Beam Energy Rate Setting Particle Type Events Data Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle
  288   Sun Nov 7 19:05:15 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2116 175.3nominal  Good  10   none 

Start: 09:38
WET measurement of PMMA slabs also used for TOF-CT (GSI)

1cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

  289   Sun Nov 7 19:06:06 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2117 175.3nominal  Good  10   none 

Start: 10:06
WET measurement of PMMA slabs also used for TOF-CT (GSI)

2cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

  290   Sun Nov 7 19:06:26 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2118 175.3nominal  Good  10   none 

Start: 10:30
WET measurement of PMMA slabs also used for TOF-CT (GSI)

3cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

  291   Sun Nov 7 19:06:40 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2119 175.3nominal  Good  10   none 

Start: 11:00
WET measurement of PMMA slabs also used for TOF-CT (GSI)

4cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

  292   Sun Nov 7 19:06:58 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2120 175.3nominal  Good  10   none 

Start: 11:24
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

  293   Sun Nov 7 19:07:31 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2121 194.3nominal  Good  10   none 

Start: 11:44
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA. higher energy for Felix Feichtinger
"Accumalte Charge"

coarse run

  294   Sun Nov 7 19:08:47 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2122 194.3nominal  Good  10   none 

Start: 12:00
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA. higher energy for Felix Feichtinger
"Accumalte Charge"

more detailed measurement

  146   Tue Mar 16 14:51:53 2021 Patrick SiebererPad Sensoren1 62.4III(EFE+SID2)Proton Unknown      none 

Start: 06:38
Range Shifter Out, Filter 1 IN, Filter 2 IN
Scintillators in front

  147   Tue Mar 16 14:54:07 2021 Patrick SiebererPad Sensoren2 145.4III(EFE+SID2)Proton Good      none 

Start: 06:45
Range Shifter Out, Filter 1 IN, Filter 2 IN
Scintillators in front

  148   Tue Mar 16 14:54:40 2021 Patrick SiebererPad Sensoren3 252.7III(EFE+SID2)Proton Good      none 

Start: 07:00
Range Shifter Out, Filter 1 IN, Filter 2 IN
Scintillators in front

  149   Tue Mar 16 14:55:06 2021 Patrick SiebererPad Sensoren4 252.7III(EFE+SID2)Proton Good      none 

Start: 07:30
Range Shifter Out, Filter 1 IN, Filter 2 IN
Before the run we went inside to: put scintillators behind the sensors, reset the fpga counters

  150   Tue Mar 16 14:55:52 2021 Patrick SiebererPad Sensoren5 194.3III(EFE+SID2)Proton Good      none 

Start: 07:38
Range Shifter Out, Filter 1 IN, Filter 2 IN
Scintillators in front
 

  151   Tue Mar 16 14:56:22 2021 Patrick SiebererPad Sensoren6 145.4III(EFE+SID2)Proton Good      none 

Start: 07:42
Range Shifter Out, Filter 1 IN, Filter 2 IN

  152   Tue Mar 16 14:57:21 2021 Patrick SiebererPad Sensoren7 62.4III(EFE+SID2)Proton Good      none 

Start: 07:54
Range Shifter Out, Filter 1 IN, Filter 2 IN

  153   Tue Mar 16 14:57:41 2021 Patrick SiebererPad Sensoren8 62.4I(EFE+SID0)Proton Good      none 

Start: 08:20
Range Shifter Out, Filter 1 IN, Filter 2 IN

  154   Tue Mar 16 14:58:37 2021 Patrick SiebererPad Sensoren9 145.4I(EFE+SID0)Proton Good      none 

Start: 08:34
Range Shifter Out, Filter 1 IN, Filter 2 IN
After that run: Downtime 8:40-10:09

  155   Tue Mar 16 14:59:18 2021 Patrick SiebererPad Sensoren10 145.4I(EFE+SID0)Proton Good      none 

Start: 10:09
Range Shifter Out, Filter 1 IN, Filter 2 IN
Interrupt run at 10:11 -> trying to deactivate filter from the beam room -> didn't work

  156   Tue Mar 16 15:00:37 2021 Patrick SiebererPad Sensoren11 145.4I(EFE+SID0)Proton Good      none 

Start: 10:18
Range Shifter Out, Filter 1 IN, Filter 2 IN
Restarting run with the same settings

  157   Tue Mar 16 15:03:04 2021 Patrick SiebererPad Sensoren12 194.3I(EFE+SID0)Proton Good      none 

Start: 10:24
Range Shifter Out, Filter 1 IN, Filter 2 IN

  158   Tue Mar 16 15:03:23 2021 Patrick SiebererPad Sensoren13 252.7I(EFE+SID0)Proton Good      none 

Start: 10:31
Range Shifter Out, Filter 1 IN, Filter 2 IN
10:57 went inside to restart the Trenz NUC PC + FPGA