Entry  Tue Mar 16 15:00:37 2021, Patrick Sieberer, Pad Sensoren, 11, , 145.4, I(EFE+SID0), Proton, , Good, , , , , , , none,  
Start: 10:18
Range Shifter Out, Filter 1 IN, Filter 2 IN
Restarting run with the same settings 
Entry  Tue Mar 16 15:03:04 2021, Patrick Sieberer, Pad Sensoren, 12, , 194.3, I(EFE+SID0), Proton, , Good, , , , , , , none,  
Start: 10:24
Range Shifter Out, Filter 1 IN, Filter 2 IN
Entry  Tue Mar 16 15:03:23 2021, Patrick Sieberer, Pad Sensoren, 13, , 252.7, I(EFE+SID0), Proton, , Good, , , , , , , none,  
Start: 10:31
Range Shifter Out, Filter 1 IN, Filter 2 IN
10:57 went inside to restart the Trenz NUC PC + FPGA
Entry  Tue Mar 16 15:04:21 2021, Patrick Sieberer, Pad Sensoren, 14, , 62.4, II(BETA+EFE), Proton, , Good, , , , , , , none,  
Start: 11:14
Range Shifter Out, Filter 1 IN, Filter 2 IN
Entry  Tue Mar 16 15:04:52 2021, Patrick Sieberer, Pad Sensoren, 15, , 145.4, II(BETA+EFE), Proton, , Good, , , , , , , none,  
Start: 11:26
Range Shifter Out, Filter 1 IN, Filter 2 IN
Entry  Tue Mar 16 15:05:08 2021, Patrick Sieberer, Pad Sensoren, 16, , 100.4, II(BETA+EFE), Proton, , Good, , , , , , , none,  
Start: 11:38
Range Shifter Out, Filter 1 IN, Filter 2 IN
Entry  Tue Mar 16 15:05:24 2021, Patrick Sieberer, Pad Sensoren, 17, , 194.3, II(BETA+EFE), Proton, , Good, , , , , , , none,  
Start: 11:46
Range Shifter Out, Filter 1 IN, Filter 2 IN
Entry  Tue Mar 16 15:05:40 2021, Patrick Sieberer, Pad Sensoren, 18, , 252.7, II(BETA+EFE), Proton, , Good, , , , , , , none,  
Start: 11:57
Range Shifter Out, Filter 1 IN, Filter 2 IN
Lost beam at 12:15
Entry  Tue Mar 16 15:06:13 2021, Patrick Sieberer, Pad Sensoren, 19, , 252.7, II(BETA+EFE), Proton, , Good, , , , , , , none,  
Start: 12:18
Range Shifter Out, Filter 1 IN, Filter 2 IN
Restart run with same settings
Entry  Tue Mar 16 15:07:06 2021, Patrick Sieberer, Pad Sensoren, 20, , 100.4, I(EFE+SID0), Proton, , Good, , , , , , , none,  
Start: 12:25
Range Shifter Out, Filter 1 IN, Filter 2 IN
Changed compliance of both sensors to 100 uA
Entry  Tue Mar 16 15:07:56 2021, Patrick Sieberer, Pad Sensoren, 21, , 100.4, III(EFE+SID2), Proton, , Good, , , , , , , none,  
Start: 12:41
Range Shifter Out, Filter 1 IN, Filter 2 IN
12:53 went inside to test if sensors are activated
Entry  Tue Mar 16 15:09:04 2021, Patrick Sieberer, Pad Sensoren, 22, , 800, V, Proton, , Good, , , , , , , none,  
Start: 13:09
Range Shifter Out, Filter 1 IN, Filter 2 IN
Changed compliance values back to 30 uA
Entry  Tue Mar 16 15:09:33 2021, Patrick Sieberer, Pad Sensoren, 23, , 800, VII, Proton, , Good, , , , , , , none,  
Start: 13:36
Range Shifter Out, Filter 1 IN, Filter 2 IN
Entry  Tue Mar 16 15:10:11 2021, Patrick Sieberer, Pad Sensoren, 24, , 252.7, nominal, Proton, , Good, , , 10, , , , none,  
Start: 13:57
Range Shifter Out, Filter 1 IN, Filter 2 IN
Entry  Tue Mar 16 15:10:41 2021, Patrick Sieberer, Pad Sensoren, 25, , 252.7, nominal, Proton, , Good, , , 50, , , , none,  
Start: 14:06
Range Shifter Out, Filter 1 IN, Filter 2 IN
Entry  Tue Mar 16 15:11:00 2021, Patrick Sieberer, Pad Sensoren, 26, , 252.7, nominal, Proton, , Good, , , 100, , , , none,  
Start: 14:20
Range Shifter Out, Filter 1 IN, Filter 2 IN
Entry  Tue Mar 16 15:11:34 2021, Patrick Sieberer, Pad Sensoren, 27, , 252.7, nominal, Proton, , Good, , , 100, , , , none,  
Start: 14:28
Range Shifter Out, Filter 1 IN, Filter 2 IN
Power supply of si-sensor went into compliance, therefore the compliance value was set to 100 uA again
Entry  Tue Mar 16 15:12:04 2021, Patrick Sieberer, MPW2 Analog output, 10, MPW2+Picoscope, 252.7, I(EFE+SID0), Proton, , Crap, , , , , , , ,  
3er Koinzidenz
Pix 06, 33, 34
Entry  Tue Mar 16 15:13:34 2021, Patrick Sieberer, MPW2 Analog output, 11, MPW2+Picoscope, 252.7, I(EFE+SID0), Proton, , Good, , , , , , , ,  
3er Koinzidenz
Pix 06, 33, 34
Entry  Tue Mar 16 15:13:58 2021, Patrick Sieberer, MPW2 Analog output, 12, MPW2+Picoscope, 252.7, I(EFE+SID0), Proton, , Good, , , , , , , ,  
2er Koinzidenz
Pix 06, 33, 34
Ratenmessunge fuer spaeteres Tracking
ELOG V3.1.5-fc6679b