Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 4 of 18  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Eventsdown Data Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle
  14   Sun Jan 10 06:52:09 2021 Maximilian TomaschekLowflux recommissioning16Ramon+Tracker62.4  30 spills 10% 101 2  

Rate, now Beta 10%

  15   Sun Jan 10 06:52:24 2021 Maximilian TomaschekLowflux recommissioning17Ramon+Tracker252.7  30 spills 10% 101 0  

Rate, now Beta 10%, looks like Beta EFE also ~400kHz

  16   Sun Jan 10 07:01:04 2021 Maximilian TomaschekLowflux recommissioning18Ramon+Tracker252.7  30 spills   101 0  

Rate, now Beta nominal again, looks like old setting 4-6 Mhz

  17   Sun Jan 10 07:02:15 2021 Maximilian TomaschekLowflux recommissioning19Ramon+Tracker194.3  30 spillsCrap  101 0  

Rate, Beta nominal, ERROR tracker  -> reset TLU

  18   Sun Jan 10 07:03:56 2021 Maximilian TomaschekLowflux recommissioning20Ramon+Tracker175.3  30 spillsGood  101 0  

Rate, Beta nominal

  20   Sun Jan 10 07:05:52 2021 Maximilian TomaschekLowflux recommissioning23Ramon+Tracker100.4  30 spillsCrap  101 0  

Rate, Beta nominal, suddenly no tracker events

  21   Sun Jan 10 07:14:54 2021 Maximilian TomaschekLowflux recommissioning24Ramon+Tracker83  30 spillsCrap  101 0  

Rate, Beta nominal, no tracker data

  22   Sun Jan 10 07:17:44 2021 Maximilian TomaschekLowflux recommissioning25Ramon+Tracker62.4  30 spillsCrap  101 0  

Rate, Beta nominal, no tracker data

  23   Sun Jan 10 07:18:16 2021 Maximilian TomaschekLowflux recommissioning26Ramon+Tracker   30 spillsGood        

Spotsize test, nach power cycle

  24   Sun Jan 10 07:19:03 2021 Maximilian TomaschekLowflux recommissioning27Ramon+Tracker   30 spillsGood        

Spotsize test, nach power cycle

  47   Wed Jan 20 17:12:15 2021 Felix Ulrich-PurLowflux recommissioning4Ramon+Tracker145.4  30 spills 10% 101    

Rate

  48   Wed Jan 20 17:15:32 2021 Felix Ulrich-PurLowflux recommissioning13Ramon+Tracker145.4  30 spills 10% 101 2  

Rate

  49   Wed Jan 20 17:25:34 2021 Felix Ulrich-PurLowflux p800 commissioning56Ramon+Tracker800  30 spills 10%60%20106dB   

MT=1, BSY=50,
1cm off in +x and +y direction
Setting IV

  50   Wed Jan 20 17:27:58 2021 Felix Ulrich-PurLowflux p800 commissioning57Ramon+Tracker800  30 spills 10%60%20106dB   

MT=1, BSY=50,
2cm off in +x and +y direction (wrong direction)
setting IV
 

  51   Wed Jan 20 17:28:56 2021 Felix Ulrich-PurLowflux p800 commissioning58Ramon+Tracker800  30 spills 10%60%20106dB   

MT=1, BSY=50,
looks +0.5vcm x, -0.5cm y
rate quite low
setting IV
 

  52   Wed Jan 20 17:29:42 2021 Felix Ulrich-PurLowflux p800 commissioning59Ramon+Tracker800  30 spills 10%60%20106dB   

MT=1, BSY=50,
x is centered now, y looks 0.25cm off
setting IV
 

  53   Wed Jan 20 17:30:17 2021 Felix Ulrich-PurLowflux p800 commissioning60Ramon+Tracker800  30 spills 10%60%20106dB   

MT=1, BSY=50,
rate few 100Hz
x looks off, y centered now (after -0.25cm in y correction)
setting IV
 

  54   Wed Jan 20 17:31:04 2021 Felix Ulrich-PurLowflux p800 commissioning61Ramon+Tracker800  30 spillsCrap10%60%10106dB   

wrong degrader setting
setting IV
 

  55   Wed Jan 20 17:31:30 2021 Felix Ulrich-PurLowflux p800 commissioning63Ramon+Tracker800  30 spills 10%60%20106dB   

MT=1, BSY=50,
beam almost centered (total correction +15mm x (to the left in beam direction) and +7.5 mm y (down in beam direction)

rate between 100Hz and 70 kHz
setting IV
 

  56   Wed Jan 20 17:33:58 2021 Felix Ulrich-PurLowflux p800 commissioning64Ramon+Tracker800  30 spills 10%60%20106dB   

MT=1, BSY=50,
beam  centered (total correction +12.5mm x (to the left in beam direction) and +7.5 mm y (down in beam direction)

rate between 100Hz and 70 kHz, few 100Hz spills
setting IV
 

ELOG V3.1.5-fc6679b