ID |
Date |
Author |
Subject |
Run Number |
DUT |
Beam Energy |
Rate Setting |
Particle Type |
Events |
Data |
Beam Betatron |
Beam Chopper |
Beam Degrader |
Beam EFE |
Beam Orb |
Beam QuadScan |
PhantomType |
PhantomAngle |
14
|
Sun Jan 10 06:52:09 2021 |
Maximilian Tomaschek | Lowflux recommissioning | 16 | Ramon+Tracker | 62.4 | | | 30 spills | | 10% | | 10 | 1 | | 2 | | |
Rate, now Beta 10% |
15
|
Sun Jan 10 06:52:24 2021 |
Maximilian Tomaschek | Lowflux recommissioning | 17 | Ramon+Tracker | 252.7 | | | 30 spills | | 10% | | 10 | 1 | | 0 | | |
Rate, now Beta 10%, looks like Beta EFE also ~400kHz |
16
|
Sun Jan 10 07:01:04 2021 |
Maximilian Tomaschek | Lowflux recommissioning | 18 | Ramon+Tracker | 252.7 | | | 30 spills | | | | 10 | 1 | | 0 | | |
Rate, now Beta nominal again, looks like old setting 4-6 Mhz |
17
|
Sun Jan 10 07:02:15 2021 |
Maximilian Tomaschek | Lowflux recommissioning | 19 | Ramon+Tracker | 194.3 | | | 30 spills | Crap | | | 10 | 1 | | 0 | | |
Rate, Beta nominal, ERROR tracker -> reset TLU |
18
|
Sun Jan 10 07:03:56 2021 |
Maximilian Tomaschek | Lowflux recommissioning | 20 | Ramon+Tracker | 175.3 | | | 30 spills | Good | | | 10 | 1 | | 0 | | |
Rate, Beta nominal |
20
|
Sun Jan 10 07:05:52 2021 |
Maximilian Tomaschek | Lowflux recommissioning | 23 | Ramon+Tracker | 100.4 | | | 30 spills | Crap | | | 10 | 1 | | 0 | | |
Rate, Beta nominal, suddenly no tracker events |
21
|
Sun Jan 10 07:14:54 2021 |
Maximilian Tomaschek | Lowflux recommissioning | 24 | Ramon+Tracker | 83 | | | 30 spills | Crap | | | 10 | 1 | | 0 | | |
Rate, Beta nominal, no tracker data |
22
|
Sun Jan 10 07:17:44 2021 |
Maximilian Tomaschek | Lowflux recommissioning | 25 | Ramon+Tracker | 62.4 | | | 30 spills | Crap | | | 10 | 1 | | 0 | | |
Rate, Beta nominal, no tracker data |
23
|
Sun Jan 10 07:18:16 2021 |
Maximilian Tomaschek | Lowflux recommissioning | 26 | Ramon+Tracker | | | | 30 spills | Good | | | | | | | | |
Spotsize test, nach power cycle |
24
|
Sun Jan 10 07:19:03 2021 |
Maximilian Tomaschek | Lowflux recommissioning | 27 | Ramon+Tracker | | | | 30 spills | Good | | | | | | | | |
Spotsize test, nach power cycle |
47
|
Wed Jan 20 17:12:15 2021 |
Felix Ulrich-Pur | Lowflux recommissioning | 4 | Ramon+Tracker | 145.4 | | | 30 spills | | 10% | | 10 | 1 | | | | |
Rate |
48
|
Wed Jan 20 17:15:32 2021 |
Felix Ulrich-Pur | Lowflux recommissioning | 13 | Ramon+Tracker | 145.4 | | | 30 spills | | 10% | | 10 | 1 | | 2 | | |
Rate |
49
|
Wed Jan 20 17:25:34 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 56 | Ramon+Tracker | 800 | | | 30 spills | | 10% | 60% | 20 | 10 | 6dB | | | |
MT=1, BSY=50,
1cm off in +x and +y direction
Setting IV |
50
|
Wed Jan 20 17:27:58 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 57 | Ramon+Tracker | 800 | | | 30 spills | | 10% | 60% | 20 | 10 | 6dB | | | |
MT=1, BSY=50,
2cm off in +x and +y direction (wrong direction)
setting IV
|
51
|
Wed Jan 20 17:28:56 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 58 | Ramon+Tracker | 800 | | | 30 spills | | 10% | 60% | 20 | 10 | 6dB | | | |
MT=1, BSY=50,
looks +0.5vcm x, -0.5cm y
rate quite low
setting IV
|
52
|
Wed Jan 20 17:29:42 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 59 | Ramon+Tracker | 800 | | | 30 spills | | 10% | 60% | 20 | 10 | 6dB | | | |
MT=1, BSY=50,
x is centered now, y looks 0.25cm off
setting IV
|
53
|
Wed Jan 20 17:30:17 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 60 | Ramon+Tracker | 800 | | | 30 spills | | 10% | 60% | 20 | 10 | 6dB | | | |
MT=1, BSY=50,
rate few 100Hz
x looks off, y centered now (after -0.25cm in y correction)
setting IV
|
54
|
Wed Jan 20 17:31:04 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 61 | Ramon+Tracker | 800 | | | 30 spills | Crap | 10% | 60% | 10 | 10 | 6dB | | | |
wrong degrader setting
setting IV
|
55
|
Wed Jan 20 17:31:30 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 63 | Ramon+Tracker | 800 | | | 30 spills | | 10% | 60% | 20 | 10 | 6dB | | | |
MT=1, BSY=50,
beam almost centered (total correction +15mm x (to the left in beam direction) and +7.5 mm y (down in beam direction)
rate between 100Hz and 70 kHz
setting IV
|
56
|
Wed Jan 20 17:33:58 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 64 | Ramon+Tracker | 800 | | | 30 spills | | 10% | 60% | 20 | 10 | 6dB | | | |
MT=1, BSY=50,
beam centered (total correction +12.5mm x (to the left in beam direction) and +7.5 mm y (down in beam direction)
rate between 100Hz and 70 kHz, few 100Hz spills
setting IV
|