ID |
Date |
Author |
Subject |
Run Number |
DUT |
Beam Energy |
Rate Setting |
Particle Type |
Events |
Data |
Beam Betatron |
Beam Chopper |
Beam Degrader |
Beam EFE |
Beam Orb |
Beam QuadScan |
PhantomType |
PhantomAngle |
61
|
Wed Jan 20 17:42:02 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 68 | Ramon+Tracker | 800 | | | 30 spills | | 11% | 60% | 20 | 10 | 6dB | | | |
MT=1, BSY=50,
setting IV
|
62
|
Wed Jan 20 17:42:31 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 69 | Ramon+Tracker | 800 | | | 30 spills | | 11% | 60.5% | 20 | 10 | 6dB | | | |
MT=1, BSY=50,
setting IV
|
63
|
Wed Jan 20 17:42:38 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 71 | Ramon+Tracker | 800 | | | 30 spills | | 11% | 60.25% | 20 | 10 | 6dB | | | |
MT=1, BSY=50,
setting IV
|
64
|
Wed Jan 20 17:44:19 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 73 | Ramon+Tracker | 800 | | | 30 spills | | 100% | 60.5% | 20 | 10 | 6dB | | | |
MT=1, BSY=50,
setting V
spot still centered
quite stable
~120kHz
steering setting IV |
65
|
Wed Jan 20 17:46:32 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 74 | Ramon+Tracker | 800 | | | 30 spills | | 11% | 60.5% | 20 | 30 | 6dB | | | |
MT=1, BSY=50,
potential setting VI
few outlier, fewer fluctuations
steering setting IV |
66
|
Wed Jan 20 17:47:24 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 75 | Ramon+Tracker | 800 | | | 30 spills | | 12% | 60.5% | 20 | 30 | 6dB | | | |
MT=1, BSY=50,
setting VI
few outlier, fewer fluctuations
final setting VI
steering setting IV |
67
|
Wed Jan 20 17:47:53 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 76 | Ramon+Tracker | 800 | | | 30 spills | | 100% | 60.5% | 20 | 30 | 6dB | | | |
MT=1, BSY=50,
beam off
potential setting VII
steering setting IV |
68
|
Wed Jan 20 17:51:28 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 77 | Ramon+Tracker | 800 | | | 30 spills | | 100% | 60.5% | 20 | 30 | 6dB | | | |
MT=1, BSY=50,
beam off
potential setting VII
steering setting IV + 1cm in +y direction |
69
|
Wed Jan 20 17:51:50 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 79 | Ramon+Tracker | 800 | | | 30 spills | | 100% | 60.5% | 20 | 30 | 6dB | | | |
MT=1, BSY=50
beam off
potential setting VII
steering setting IV + 1cm in +y direction |
70
|
Wed Jan 20 17:52:12 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 80 | Ramon+Tracker | 800 | | | 30 spills | | 100% | 60.5% | 20 | 30 | 6dB | | | |
MT=1, BSY=50
beam off
potential setting VII
steering setting IV + shift in -y direction |
71
|
Wed Jan 20 17:52:28 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 81 | Ramon+Tracker | 800 | | | 30 spills | | 100% | 60.5% | 20 | 30 | 6dB | | | |
MT=1, BSY=50,
beam off
potential setting VII
steering setting IV + bigger shift in -y direction |
72
|
Wed Jan 20 17:52:49 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 82 | Ramon+Tracker | 800 | | | 30 spills | | 100% | 60.5% | 20 | 30 | 6dB | | | |
MT=1, BSY=50,
potential setting VII
new steering +12.5mm x,+10mm y ( -beam direction), still off |
73
|
Wed Jan 20 17:55:13 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 83 | Ramon+Tracker | 800 | | | 30 spills | | 100% | 60.5% | 20 | 30 | 6dB | | | |
MT=1, BSY=50,
final setting VII
new steering VII +12.5mm x,+13mm y ( -beam direction) |
74
|
Wed Jan 20 17:56:06 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 84 | Ramon+Tracker | 800 | | | 30 spills | | 12% | 60.5% | 20 | 30 | 6dB | | | |
MT=1, BSY=50,
setting VI steering VII,beam is off again |
75
|
Wed Jan 20 17:57:16 2021 |
Felix Ulrich-Pur | Lowflux p800 commissioning | 85 | Ramon+Tracker | 800 | | | 30 spills | Unknown | 100% | 60.5% | 20 | 10 | 6dB | | | |
MT=1, BSY=50,
setting V steering VII,beam looks centered, but rate and spot looks similar to setting VII, maybe wrong acc setting? --> don't use |
76
|
Sat Feb 27 09:26:27 2021 |
Felix Ulrich-Pur | Rate verification | 1 | SiC+Si+RaMon | 62.4 | III(EFE+SID2) | | | Unknown | | | | | | | | |
Start 06:37
rate looks okish. few emtpy spills
2021-02-27, 06:07:
channel 1 : Si upstream
channel 2: SiC downstream
400 V Bias
Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.112V channel 1, 0-Level: 2.315V channel 1
position:
x: 0
y: 0
2021-02-27, 06:30:
Referenz: 2.477V channel 1
channel 2 unverändert
2021-02-27, 06:37:
Setting: 3
Run 1: 6:37 62.4 MeV, Rate geringer als erwartet
|
77
|
Sat Feb 27 09:28:07 2021 |
Felix Ulrich-Pur | Rate verification | 2 | SiC+Si+RaMon | 252.7 | III(EFE+SID2) | | | Crap | | | | | | | | |
Start 06:47
rate only 10Hz, stopped run, room request and rewired trigger.
NOTE: Problem was caused by operators: Optics were not set correctly after ramping up energy from 62.4 to 252.7, not trigger cable
channel 1 : Si upstream
channel 2: SiC downstream
400 V Bias
Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1
position:
x: 0
y: 0 |
78
|
Sat Feb 27 09:29:41 2021 |
Felix Ulrich-Pur | Rate verification | 4 | SiC+Si+RaMon | 252.7 | III(EFE+SID2) | | | Good | | | | | | | | |
Start 06:55
reallocated correctly, rate looks similar to old measurements now (kHz ish)
channel 1 : Si upstream
channel 2: SiC downstream
400 V Bias
Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1
position:
x: 0
y: 0 |
79
|
Sat Feb 27 09:30:32 2021 |
Felix Ulrich-Pur | Rate verification | 5 | SiC+Si+RaMon | 62.4 | III(EFE+SID2) | | | Good | | | | | | | | |
Start 07:03
verified if run 1 was reliable-->Same results
channel 1 : Si upstream
channel 2: SiC downstream
400 V Bias
Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1
position:
x: 0
y: 0 |
80
|
Sat Feb 27 09:31:57 2021 |
Felix Ulrich-Pur | Rate verification | 6 | SiC+Si+RaMon | 252.7 | I(EFE+SID0) | | | Good | | | | | | | | |
Start 07:16
rate looks fine,
channel 1 : Si upstream
channel 2: SiC downstream
400 V Bias
Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1
position:
x: 0
y: 0
SiC: man sieht erstmals Signale |