Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 3 of 18  Not logged in ELOG logo
IDdown Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Data Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle
  311   Sat Oct 8 07:10:31 2022 Christian IrmlerRD50-MPW3 - First Testbeam               

Tracker xml file: hvcmos_mpw3_20221008_TLU_00-000053.xml

 

  310   Sat Dec 11 18:19:56 2021 Felix Ulrich-PurFluence loss 1cm5DSSD-Tracker800VProton Good      Alu0 deg

Fluence loss measurement 11.12.2021

Start 18:17

90deg = all five steps Alu

  309   Sat Dec 11 17:48:08 2021 Felix Ulrich-PurFluence loss 1cm4DSSD-Tracker800VProton Good      Alu0 deg

Fluence loss measurement 11.12.2021

Start 15:15

0deg =1cm Alu

  308   Sat Dec 11 17:47:52 2021 Felix Ulrich-PurAlignment run3DSSD-Tracker800VProton Good      none 

Fluence loss measurement 11.12.2021

 

 

  307   Sat Dec 11 17:47:45 2021 Felix Ulrich-PurAlignment run2DSSD-Tracker800VProton Good      none 

Fluence loss measurement 11.12.2021

 

 

  306   Sat Dec 11 17:46:17 2021 Felix Ulrich-PurAlignment run1DSSD-Tracker800VProton Good      none 

Fluence loss measurement 11.12.2021

Start 14:45

 

  305   Sun Nov 21 14:53:00 2021 Simon WaidComparison SiC, Si, Si LGAD and Diamond4Diamond+LGAD62.4I(EFE+SID0)Proton100000         

Bias voltage Diamond: 500

Bias voltage Si LGAD: -100

From a beam perspective the Diamond detector was the first target, on oscilloscope channel 4, the Si LGAD was the second target connected to oscilloscope channel 1.

Triggering source was the Si LGAD detector.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

  304   Sun Nov 21 14:05:18 2021 Simon WaidComparison SiC, Si, Si LGAD and Diamond3 62.4I(EFE+SID0)Proton10000         

Bias voltage SiC: 800

Bias voltage Si LGAD: -100

From a beam perspective the SiC detector was the first target, on oscilloscope channel 4, the Si LGAD was the second target connected to oscilloscope channel 1.

Triggering source was the Si LGAD detector. The SiC detector was most probably defective.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

  303   Sun Nov 21 13:55:05 2021 Simon WaidComparison SiC, Si, Si LGAD and Diamond2SiC+Si62.4I(EFE+SID0)Proton1000000         

Bias voltage SiC: 800

Bias voltage Si: -150

From a beam perspective the Si detector was the first target, on oscilloscope  channel 1, SiC was the second target connected to oscilloscope channel 3.

Triggering source was the Si detector.

The compliancy of the SiC SMU triggered after approx. 50% of the events had been acquired after this event the HV for the SiC HV was shut down.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

  302   Sun Nov 21 13:51:53 2021 Simon WaidComparison SiC, Si, Si LGAD and Diamond1SiC+Si62.4I(EFE+SID0)Proton10000         

Bias voltage SiC: 800

Bias voltage Si: -150

From a beam perspective the Si detector was the first target, on oscilloscope  channel 1, SiC was the second target connected to oscilloscope channel 3.

Triggering source was the SiC detector.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

  301   Sun Nov 7 21:04:43 2021 Felix Ulrich-PurFluence loss meas 7.11.2130 100.4II(BETA+EFE)Proton40e6Good      none 

Start: 21.04

reference run 100.4MeV

  300   Sun Nov 7 19:28:49 2021 Felix Ulrich-PurFluence loss meas 7.11.2129Drehtisch100.4II(BETA+EFE)Proton60e6Good      Alu0

Start: 19:28

1 cm Alu stair phantom on rotary table (0deg)

  299   Sun Nov 7 19:13:36 2021 Felix Ulrich-PurFluence loss meas 7.11.2128Drehtisch100.4II(BETA+EFE)Proton60e6Good      Alu90

Start: 18:00

1 cm Alu stair phantom on rotary table (90deg)

  298   Sun Nov 7 19:12:57 2021 Felix Ulrich-PurFluence loss meas 7.11.2127Drehtisch145.4II(BETA+EFE)Proton60e6Good      Alu90

Start: 16:40

1 cm Alu stair phantom on rotary table (90deg--> 0.2-1cm Alu)

  297   Sun Nov 7 19:11:24 2021 Felix Ulrich-PurFluence loss meas 7.11.2126Drehtisch145.4II(BETA+EFE)Proton60e6Good      Alu0

Start: 15:19

1 cm Alu stair phantom on rotary table (0deg--> always 1cm Al in beam)

  296   Sun Nov 7 19:10:31 2021 Felix Ulrich-PurFluence loss meas 7.11.2125 145.4II(BETA+EFE)Proton40e6Good      none 

Start: 14:04

Reference run without phantom

  295   Sun Nov 7 19:09:50 2021 Felix Ulrich-PurFluence loss meas 7.11.2124 252.7II(BETA+EFE)Proton Good      none 

Start: 13:58

Alignment run without phantom

  294   Sun Nov 7 19:08:47 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2122 194.3nominal  Good  10   none 

Start: 12:00
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA. higher energy for Felix Feichtinger
"Accumalte Charge"

more detailed measurement

  293   Sun Nov 7 19:07:31 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2121 194.3nominal  Good  10   none 

Start: 11:44
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA. higher energy for Felix Feichtinger
"Accumalte Charge"

coarse run

  292   Sun Nov 7 19:06:58 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2120 175.3nominal  Good  10   none 

Start: 11:24
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

ELOG V3.1.5-fc6679b