ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Data Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orbdown Beam QuadScan PhantomType PhantomAngle Text Attachments
  69   Wed Jan 20 17:51:50 2021 Felix Ulrich-PurLowflux p800 commissioning79Ramon+Tracker800  30 spills 100%60.5%20306dB   MT=1, BSY=50

beam off
potential setting VII
  
  70   Wed Jan 20 17:52:12 2021 Felix Ulrich-PurLowflux p800 commissioning80Ramon+Tracker800  30 spills 100%60.5%20306dB   MT=1, BSY=50

beam off
potential setting VII
  
  71   Wed Jan 20 17:52:28 2021 Felix Ulrich-PurLowflux p800 commissioning81Ramon+Tracker800  30 spills 100%60.5%20306dB   MT=1, BSY=50,

beam off
potential setting VII
  
  72   Wed Jan 20 17:52:49 2021 Felix Ulrich-PurLowflux p800 commissioning82Ramon+Tracker800  30 spills 100%60.5%20306dB   MT=1, BSY=50,
potential setting VII
new steering +12.5mm x,+10mm y ( -beam
  
  73   Wed Jan 20 17:55:13 2021 Felix Ulrich-PurLowflux p800 commissioning83Ramon+Tracker800  30 spills 100%60.5%20306dB   MT=1, BSY=50,
final setting VII
new steering VII +12.5mm x,+13mm y
  
  74   Wed Jan 20 17:56:06 2021 Felix Ulrich-PurLowflux p800 commissioning84Ramon+Tracker800  30 spills 12%60.5%20306dB   MT=1, BSY=50,
setting VI steering VII,beam is off
again
  
  75   Wed Jan 20 17:57:16 2021 Felix Ulrich-PurLowflux p800 commissioning85Ramon+Tracker800  30 spillsUnknown100%60.5%20106dB   MT=1, BSY=50,
setting V steering VII,beam looks
centered, but rate and spot looks similar
  
  1   Sun Jan 10 06:27:26 2021 Maximilian TomaschekLowflux recommissioning1Ramon+Tracker252.7  30 spills 10% 101    Rate,15s spill pause, delay can be set
by operator
  
  2   Sun Jan 10 06:32:13 2021 Maximilian TomaschekLowflux recommissioning2Ramon+Tracker194.3  30 spills 10% 101    Rate   
  3   Sun Jan 10 06:33:22 2021 Maximilian TomaschekLowflux recommissioning3Ramon+Tracker175.3  30 spills 10% 101    Rate   
  4   Sun Jan 10 06:33:44 2021 Maximilian TomaschekLowflux recommissioning5Ramon+Tracker100.4  30 spills 10% 101    Rate   
  5   Sun Jan 10 06:38:16 2021 Maximilian TomaschekLowflux recommissioning6Ramon+Tracker83  30 spills 10% 101    Rate   
  6   Sun Jan 10 06:40:06 2021 Maximilian TomaschekLowflux recommissioning7Ramon+Tracker62.4  30 spills 10% 101    Rate, up till now looks like the same   
  7   Sun Jan 10 06:42:03 2021 Maximilian TomaschekLowflux recommissioning8Ramon+Tracker252.7  30 spills   101 2  Rate, factor 10 too high, role ~30kHz instead
of 3kHz, Beta nominal
  
  8   Sun Jan 10 06:44:59 2021 Maximilian TomaschekLowflux recommissioning9Ramon+Tracker62.4  30 spills   101 2  Rate, Beta nominal, factor 10 too high   
  9   Sun Jan 10 06:45:55 2021 Maximilian TomaschekLowflux recommissioning10Ramon+Tracker252.7  30 spills 10% 101 2  Rate, Beta 10% nominal, now 3kHz   
  10   Sun Jan 10 06:46:56 2021 Maximilian TomaschekLowflux recommissioning11Ramon+Tracker194.3  30 spills 10% 101 2  Rate, Beta 10% nominal   
  11   Sun Jan 10 06:50:45 2021 Maximilian TomaschekLowflux recommissioning12Ramon+Tracker175.3  30 spills 10% 101 2  Rate   
  12   Sun Jan 10 06:51:12 2021 Maximilian TomaschekLowflux recommissioning14Ramon+Tracker100.4  30 spills 10% 101 2  Rate, now Beta 10%   
  13   Sun Jan 10 06:51:57 2021 Maximilian TomaschekLowflux recommissioning15Ramon+Tracker83  30 spills 10% 101 2  Rate, now Beta 10%   