Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 2 of 18  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Data Beam Betatron Beam Chopper Beam Degrader Beam EFEdown Beam Orb Beam QuadScan PhantomType PhantomAngle Text Attachments
  58   Wed Jan 20 17:35:51 2021 Felix Ulrich-PurLowflux p800 commissioning66Ramon+Tracker800  30 spills 10%62%20106dB   MT=1, BSY=50,
beam is centered
rate few 100kHz and two peaks in beam
  
  59   Wed Jan 20 17:36:21 2021 Felix Ulrich-PurLowflux p800 commissioning65Ramon+Tracker800  30 spills 10%80%20106dB   MT=1, BSY=50,
beam shifted again
jumps in rate too high
  
  60   Wed Jan 20 17:41:27 2021 Felix Ulrich-PurLowflux p800 commissioning67Ramon+Tracker800  30 spills 10%60.5%20106dB   MT=1, BSY=50,
beam shifted again
max 30kHz, low rate
  
  61   Wed Jan 20 17:42:02 2021 Felix Ulrich-PurLowflux p800 commissioning68Ramon+Tracker800  30 spills 11%60%20106dB   MT=1, BSY=50,
setting IV
 
  
  62   Wed Jan 20 17:42:31 2021 Felix Ulrich-PurLowflux p800 commissioning69Ramon+Tracker800  30 spills 11%60.5%20106dB   MT=1, BSY=50,
setting IV
 
  
  63   Wed Jan 20 17:42:38 2021 Felix Ulrich-PurLowflux p800 commissioning71Ramon+Tracker800  30 spills 11%60.25%20106dB   MT=1, BSY=50,
setting IV
 
  
  64   Wed Jan 20 17:44:19 2021 Felix Ulrich-PurLowflux p800 commissioning73Ramon+Tracker800  30 spills 100%60.5%20106dB   MT=1, BSY=50,
setting V

spot still centered
  
  75   Wed Jan 20 17:57:16 2021 Felix Ulrich-PurLowflux p800 commissioning85Ramon+Tracker800  30 spillsUnknown100%60.5%20106dB   MT=1, BSY=50,
setting V steering VII,beam looks
centered, but rate and spot looks similar
  
  1   Sun Jan 10 06:27:26 2021 Maximilian TomaschekLowflux recommissioning1Ramon+Tracker252.7  30 spills 10% 101    Rate,15s spill pause, delay can be set
by operator
  
  2   Sun Jan 10 06:32:13 2021 Maximilian TomaschekLowflux recommissioning2Ramon+Tracker194.3  30 spills 10% 101    Rate   
  3   Sun Jan 10 06:33:22 2021 Maximilian TomaschekLowflux recommissioning3Ramon+Tracker175.3  30 spills 10% 101    Rate   
  4   Sun Jan 10 06:33:44 2021 Maximilian TomaschekLowflux recommissioning5Ramon+Tracker100.4  30 spills 10% 101    Rate   
  5   Sun Jan 10 06:38:16 2021 Maximilian TomaschekLowflux recommissioning6Ramon+Tracker83  30 spills 10% 101    Rate   
  6   Sun Jan 10 06:40:06 2021 Maximilian TomaschekLowflux recommissioning7Ramon+Tracker62.4  30 spills 10% 101    Rate, up till now looks like the same   
  7   Sun Jan 10 06:42:03 2021 Maximilian TomaschekLowflux recommissioning8Ramon+Tracker252.7  30 spills   101 2  Rate, factor 10 too high, role ~30kHz instead
of 3kHz, Beta nominal
  
  8   Sun Jan 10 06:44:59 2021 Maximilian TomaschekLowflux recommissioning9Ramon+Tracker62.4  30 spills   101 2  Rate, Beta nominal, factor 10 too high   
  9   Sun Jan 10 06:45:55 2021 Maximilian TomaschekLowflux recommissioning10Ramon+Tracker252.7  30 spills 10% 101 2  Rate, Beta 10% nominal, now 3kHz   
  10   Sun Jan 10 06:46:56 2021 Maximilian TomaschekLowflux recommissioning11Ramon+Tracker194.3  30 spills 10% 101 2  Rate, Beta 10% nominal   
  11   Sun Jan 10 06:50:45 2021 Maximilian TomaschekLowflux recommissioning12Ramon+Tracker175.3  30 spills 10% 101 2  Rate   
  12   Sun Jan 10 06:51:12 2021 Maximilian TomaschekLowflux recommissioning14Ramon+Tracker100.4  30 spills 10% 101 2  Rate, now Beta 10%   
ELOG V3.1.5-fc6679b