ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Data Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomTypedown PhantomAngle
  166   Tue Mar 16 15:07:56 2021 Patrick SiebererPad Sensoren21 100.4III(EFE+SID2)Proton Good      none 

Start: 12:41
Range Shifter Out, Filter 1 IN, Filter 2 IN
12:53 went inside to test if sensors are activated

  167   Tue Mar 16 15:09:04 2021 Patrick SiebererPad Sensoren22 800VProton Good      none 

Start: 13:09
Range Shifter Out, Filter 1 IN, Filter 2 IN
Changed compliance values back to 30 uA

  168   Tue Mar 16 15:09:33 2021 Patrick SiebererPad Sensoren23 800VIIProton Good      none 

Start: 13:36
Range Shifter Out, Filter 1 IN, Filter 2 IN

  169   Tue Mar 16 15:10:11 2021 Patrick SiebererPad Sensoren24 252.7nominalProton Good  10   none 

Start: 13:57
Range Shifter Out, Filter 1 IN, Filter 2 IN

  170   Tue Mar 16 15:10:41 2021 Patrick SiebererPad Sensoren25 252.7nominalProton Good  50   none 

Start: 14:06
Range Shifter Out, Filter 1 IN, Filter 2 IN

  171   Tue Mar 16 15:11:00 2021 Patrick SiebererPad Sensoren26 252.7nominalProton Good  100   none 

Start: 14:20
Range Shifter Out, Filter 1 IN, Filter 2 IN

  172   Tue Mar 16 15:11:34 2021 Patrick SiebererPad Sensoren27 252.7nominalProton Good  100   none 

Start: 14:28
Range Shifter Out, Filter 1 IN, Filter 2 IN
Power supply of si-sensor went into compliance, therefore the compliance value was set to 100 uA again
Ende 14:35

  215   Wed May 12 08:46:41 2021 Felix Ulrich-PurAlignment Run1DSSD-Tracker252.7II(BETA+EFE)Proton Good      none 

TB 24.4.21
Alignment run

  216   Wed May 12 08:47:53 2021 Felix Ulrich-PurAlignment Run2DSSD-Tracker252.7II(BETA+EFE)Proton Good      none 

TB 24.4.21
Alignment run

  227   Sun Jun 20 19:26:54 2021 Felix Ulrich-PurHADES testrun 800MeV1HADES-LGADs800VIIProton Good      none0

TB 19.6.21

Start 06:00
startet with wrong setting at the beginning (6 instead of 5) rate was then corrected, but RaMon was still running.

Final rate: 100kHz setting
07:24: room request: changed channel on board (was not connected to osci)

  228   Sun Jun 20 19:30:28 2021 Felix Ulrich-PurHADES testrun 100.4MeV2HADES-LGADs100.4II(BETA+EFE)Proton Good      none0

TB 19.6.21

Start 07:51
beam was paused at 10:10

bias run and threshold optimization

mean rate was O(100kHz)

  229   Sun Jun 20 19:33:06 2021 Felix Ulrich-PurHADES testrun with increased rate 100.4MeV3HADES-LGADs100.4I(EFE+SID0)Proton Good      none0

TB 19.6.21

Start 11:21
paused beam at 13:36
15:40-16:20 ECR source fail--downtime

Mean rate O(MHz)

  230   Sun Jun 20 19:34:59 2021 Felix Ulrich-PurHADES energy run4HADES-LGADs252.7I(EFE+SID0)Proton Good      none0

TB 19.6.21

Start 17:13

Mean rate O(MHz)
 

  231   Sun Jun 20 19:35:46 2021 Felix Ulrich-PurHADES energy run5HADES-LGADs194.3I(EFE+SID0)Proton Good      none0

TB 19.6.21

Start 17:42
Mean rate O(MHz)
 

  232   Sun Jun 20 19:37:09 2021 Felix Ulrich-PurHADES energy run6HADES-LGADs145.4I(EFE+SID0)Proton Good      none0

TB 19.6.21

Start 18:15
Mean rate O(MHz)
 

  233   Sun Jun 20 19:37:37 2021 Felix Ulrich-PurHADES energy run7HADES-LGADs83I(EFE+SID0)Proton Good      none0

TB 19.6.21

Start 18:48
Mean rate O(MHz)
 

  234   Sun Jun 20 19:37:58 2021 Felix Ulrich-PurHADES energy run8HADES-LGADs62.4I(EFE+SID0)Proton Good      none0

TB 19.6.21

Start 19:16
Mean rate O(MHz)
 

  235   Sun Jun 20 19:38:28 2021 Felix Ulrich-PurHADES increased rate run (wrong setting9HADES-LGADs800VIIProton Good  20   none0

TB 19.6.21

Start 19:43
rate setting was not set correctly deg20 in combination with setting VII instead of nominal flux deg10
 

  236   Sun Jun 20 19:40:12 2021 Felix Ulrich-PurHADES increased rate 10HADES-LGADs800nominalProton Good  10   none0

TB 19.6.21

Start 21:50

Nominal flux degrader 10: mean rate O(200MHz)
 

  239   Sun Jun 20 19:55:47 2021 Felix Ulrich-PurHADES sandwich TOF reference run12HADES-LGADs100.4I(EFE+SID0)Proton Good      none0

TB 20.6.21

Start 16:46
0cm Phantom thickness
Mean rate O(MHz)
reference run without phantom
for live TOF estimation: TDC3,channel 9 - TDC2,channel9
 