ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Data Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orbdown Beam QuadScan PhantomType PhantomAngle
  69   Wed Jan 20 17:51:50 2021 Felix Ulrich-PurLowflux p800 commissioning79Ramon+Tracker800  30 spills 100%60.5%20306dB   

MT=1, BSY=50

beam off
potential setting VII
steering setting IV + 1cm in +y direction

  70   Wed Jan 20 17:52:12 2021 Felix Ulrich-PurLowflux p800 commissioning80Ramon+Tracker800  30 spills 100%60.5%20306dB   

MT=1, BSY=50

beam off
potential setting VII
steering setting IV + shift in -y direction

  71   Wed Jan 20 17:52:28 2021 Felix Ulrich-PurLowflux p800 commissioning81Ramon+Tracker800  30 spills 100%60.5%20306dB   

MT=1, BSY=50,

beam off
potential setting VII
steering setting IV + bigger shift in -y direction

  72   Wed Jan 20 17:52:49 2021 Felix Ulrich-PurLowflux p800 commissioning82Ramon+Tracker800  30 spills 100%60.5%20306dB   

MT=1, BSY=50,
potential setting VII
new steering +12.5mm x,+10mm y ( -beam direction), still off

  73   Wed Jan 20 17:55:13 2021 Felix Ulrich-PurLowflux p800 commissioning83Ramon+Tracker800  30 spills 100%60.5%20306dB   

MT=1, BSY=50,
final setting VII
new steering VII +12.5mm x,+13mm y ( -beam direction)

  74   Wed Jan 20 17:56:06 2021 Felix Ulrich-PurLowflux p800 commissioning84Ramon+Tracker800  30 spills 12%60.5%20306dB   

MT=1, BSY=50,
setting VI steering VII,beam is off again

  75   Wed Jan 20 17:57:16 2021 Felix Ulrich-PurLowflux p800 commissioning85Ramon+Tracker800  30 spillsUnknown100%60.5%20106dB   

MT=1, BSY=50,
setting V steering VII,beam looks centered, but rate and spot looks similar to setting VII, maybe wrong acc setting? --> don't use

  1   Sun Jan 10 06:27:26 2021 Maximilian TomaschekLowflux recommissioning1Ramon+Tracker252.7  30 spills 10% 101    

Rate,15s spill pause, delay can be set by operator

  2   Sun Jan 10 06:32:13 2021 Maximilian TomaschekLowflux recommissioning2Ramon+Tracker194.3  30 spills 10% 101    

Rate

  3   Sun Jan 10 06:33:22 2021 Maximilian TomaschekLowflux recommissioning3Ramon+Tracker175.3  30 spills 10% 101    

Rate

  4   Sun Jan 10 06:33:44 2021 Maximilian TomaschekLowflux recommissioning5Ramon+Tracker100.4  30 spills 10% 101    

Rate

  5   Sun Jan 10 06:38:16 2021 Maximilian TomaschekLowflux recommissioning6Ramon+Tracker83  30 spills 10% 101    

Rate

  6   Sun Jan 10 06:40:06 2021 Maximilian TomaschekLowflux recommissioning7Ramon+Tracker62.4  30 spills 10% 101    

Rate, up till now looks like the same

  7   Sun Jan 10 06:42:03 2021 Maximilian TomaschekLowflux recommissioning8Ramon+Tracker252.7  30 spills   101 2  

Rate, factor 10 too high, role ~30kHz instead of 3kHz, Beta nominal

  8   Sun Jan 10 06:44:59 2021 Maximilian TomaschekLowflux recommissioning9Ramon+Tracker62.4  30 spills   101 2  

Rate, Beta nominal, factor 10 too high

  9   Sun Jan 10 06:45:55 2021 Maximilian TomaschekLowflux recommissioning10Ramon+Tracker252.7  30 spills 10% 101 2  

Rate, Beta 10% nominal, now 3kHz

  10   Sun Jan 10 06:46:56 2021 Maximilian TomaschekLowflux recommissioning11Ramon+Tracker194.3  30 spills 10% 101 2  

Rate, Beta 10% nominal

  11   Sun Jan 10 06:50:45 2021 Maximilian TomaschekLowflux recommissioning12Ramon+Tracker175.3  30 spills 10% 101 2  

Rate

  12   Sun Jan 10 06:51:12 2021 Maximilian TomaschekLowflux recommissioning14Ramon+Tracker100.4  30 spills 10% 101 2  

Rate, now Beta 10%

  13   Sun Jan 10 06:51:57 2021 Maximilian TomaschekLowflux recommissioning15Ramon+Tracker83  30 spills 10% 101 2  

Rate, now Beta 10%