Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 2 of 18  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
Entry  Tue Mar 16 15:07:56 2021, Patrick Sieberer, Pad Sensoren, 21, , 100.4, III(EFE+SID2), Proton, , Good, , , , , , , none,  

Start: 12:41
Range Shifter Out, Filter 1 IN, Filter 2 IN
12:53 went inside to test if sensors are activated

Entry  Tue Mar 16 15:09:04 2021, Patrick Sieberer, Pad Sensoren, 22, , 800, V, Proton, , Good, , , , , , , none,  

Start: 13:09
Range Shifter Out, Filter 1 IN, Filter 2 IN
Changed compliance values back to 30 uA

Entry  Tue Mar 16 15:09:33 2021, Patrick Sieberer, Pad Sensoren, 23, , 800, VII, Proton, , Good, , , , , , , none,  

Start: 13:36
Range Shifter Out, Filter 1 IN, Filter 2 IN

Entry  Tue Mar 16 15:10:11 2021, Patrick Sieberer, Pad Sensoren, 24, , 252.7, nominal, Proton, , Good, , , 10, , , , none,  

Start: 13:57
Range Shifter Out, Filter 1 IN, Filter 2 IN

Entry  Tue Mar 16 15:10:41 2021, Patrick Sieberer, Pad Sensoren, 25, , 252.7, nominal, Proton, , Good, , , 50, , , , none,  

Start: 14:06
Range Shifter Out, Filter 1 IN, Filter 2 IN

Entry  Tue Mar 16 15:11:00 2021, Patrick Sieberer, Pad Sensoren, 26, , 252.7, nominal, Proton, , Good, , , 100, , , , none,  

Start: 14:20
Range Shifter Out, Filter 1 IN, Filter 2 IN

Entry  Tue Mar 16 15:11:34 2021, Patrick Sieberer, Pad Sensoren, 27, , 252.7, nominal, Proton, , Good, , , 100, , , , none,  

Start: 14:28
Range Shifter Out, Filter 1 IN, Filter 2 IN
Power supply of si-sensor went into compliance, therefore the compliance value was set to 100 uA again
Ende 14:35

Entry  Wed May 12 08:46:41 2021, Felix Ulrich-Pur, Alignment Run, 1, DSSD-Tracker, 252.7, II(BETA+EFE), Proton, , Good, , , , , , , none,  

TB 24.4.21
Alignment run

Entry  Wed May 12 08:47:53 2021, Felix Ulrich-Pur, Alignment Run, 2, DSSD-Tracker, 252.7, II(BETA+EFE), Proton, , Good, , , , , , , none,  

TB 24.4.21
Alignment run

Entry  Sun Jun 20 19:26:54 2021, Felix Ulrich-Pur, HADES testrun 800MeV, 1, HADES-LGADs, 800, VII, Proton, , Good, , , , , , , none, 0 

TB 19.6.21

Start 06:00
startet with wrong setting at the beginning (6 instead of 5) rate was then corrected, but RaMon was still running.

Final rate: 100kHz setting
07:24: room request: changed channel on board (was not connected to osci)

Entry  Sun Jun 20 19:30:28 2021, Felix Ulrich-Pur, HADES testrun 100.4MeV, 2, HADES-LGADs, 100.4, II(BETA+EFE), Proton, , Good, , , , , , , none, 0 

TB 19.6.21

Start 07:51
beam was paused at 10:10

bias run and threshold optimization

mean rate was O(100kHz)

Entry  Sun Jun 20 19:33:06 2021, Felix Ulrich-Pur, HADES testrun with increased rate 100.4MeV, 3, HADES-LGADs, 100.4, I(EFE+SID0), Proton, , Good, , , , , , , none, 0 

TB 19.6.21

Start 11:21
paused beam at 13:36
15:40-16:20 ECR source fail--downtime

Mean rate O(MHz)

Entry  Sun Jun 20 19:34:59 2021, Felix Ulrich-Pur, HADES energy run, 4, HADES-LGADs, 252.7, I(EFE+SID0), Proton, , Good, , , , , , , none, 0 

TB 19.6.21

Start 17:13

Mean rate O(MHz)
 

Entry  Sun Jun 20 19:35:46 2021, Felix Ulrich-Pur, HADES energy run, 5, HADES-LGADs, 194.3, I(EFE+SID0), Proton, , Good, , , , , , , none, 0 

TB 19.6.21

Start 17:42
Mean rate O(MHz)
 

Entry  Sun Jun 20 19:37:09 2021, Felix Ulrich-Pur, HADES energy run, 6, HADES-LGADs, 145.4, I(EFE+SID0), Proton, , Good, , , , , , , none, 0 

TB 19.6.21

Start 18:15
Mean rate O(MHz)
 

Entry  Sun Jun 20 19:37:37 2021, Felix Ulrich-Pur, HADES energy run, 7, HADES-LGADs, 83, I(EFE+SID0), Proton, , Good, , , , , , , none, 0 

TB 19.6.21

Start 18:48
Mean rate O(MHz)
 

Entry  Sun Jun 20 19:37:58 2021, Felix Ulrich-Pur, HADES energy run, 8, HADES-LGADs, 62.4, I(EFE+SID0), Proton, , Good, , , , , , , none, 0 

TB 19.6.21

Start 19:16
Mean rate O(MHz)
 

Entry  Sun Jun 20 19:38:28 2021, Felix Ulrich-Pur, HADES increased rate run (wrong setting, 9, HADES-LGADs, 800, VII, Proton, , Good, , , 20, , , , none, 0 

TB 19.6.21

Start 19:43
rate setting was not set correctly deg20 in combination with setting VII instead of nominal flux deg10
 

Entry  Sun Jun 20 19:40:12 2021, Felix Ulrich-Pur, HADES increased rate , 10, HADES-LGADs, 800, nominal, Proton, , Good, , , 10, , , , none, 0 

TB 19.6.21

Start 21:50

Nominal flux degrader 10: mean rate O(200MHz)
 

Entry  Sun Jun 20 19:55:47 2021, Felix Ulrich-Pur, HADES sandwich TOF reference run, 12, HADES-LGADs, 100.4, I(EFE+SID0), Proton, , Good, , , , , , , none, 0 

TB 20.6.21

Start 16:46
0cm Phantom thickness
Mean rate O(MHz)
reference run without phantom
for live TOF estimation: TDC3,channel 9 - TDC2,channel9
 

ELOG V3.1.5-fc6679b