Wed Jan 20 17:29:42 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 59, Ramon+Tracker, 800, , , 30 spills, , 10%, 60%, 20, 10, 6dB, , ,
|
MT=1, BSY=50,
x is centered now, y looks 0.25cm off
setting IV
|
Wed Jan 20 17:30:17 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 60, Ramon+Tracker, 800, , , 30 spills, , 10%, 60%, 20, 10, 6dB, , ,
|
MT=1, BSY=50,
rate few 100Hz
x looks off, y centered now (after -0.25cm in y correction)
setting IV
|
Wed Jan 20 17:31:04 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 61, Ramon+Tracker, 800, , , 30 spills, Crap, 10%, 60%, 10, 10, 6dB, , ,
|
wrong degrader setting
setting IV
|
Wed Jan 20 17:31:30 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 63, Ramon+Tracker, 800, , , 30 spills, , 10%, 60%, 20, 10, 6dB, , ,
|
MT=1, BSY=50,
beam almost centered (total correction +15mm x (to the left in beam direction) and +7.5 mm y (down in beam direction)
rate between 100Hz and 70 kHz
setting IV
|
Wed Jan 20 17:33:58 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 64, Ramon+Tracker, 800, , , 30 spills, , 10%, 60%, 20, 10, 6dB, , ,
|
MT=1, BSY=50,
beam centered (total correction +12.5mm x (to the left in beam direction) and +7.5 mm y (down in beam direction)
rate between 100Hz and 70 kHz, few 100Hz spills
setting IV
|
Wed Jan 20 17:35:25 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 62, Ramon+Tracker, 800, , , 30 spills, , 10%, 60%, 20, 10, 6dB, , ,
|
MT=1, BSY=50,
now correct degrader, beam still off
setting IV
|
Wed Jan 20 17:42:02 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 68, Ramon+Tracker, 800, , , 30 spills, , 11%, 60%, 20, 10, 6dB, , ,
|
MT=1, BSY=50,
setting IV
|
Sun Jan 10 06:27:26 2021, Maximilian Tomaschek, Lowflux recommissioning, 1, Ramon+Tracker, 252.7, , , 30 spills, , 10%, , 10, 1, , , ,
|
Rate,15s spill pause, delay can be set by operator |
Sun Jan 10 06:32:13 2021, Maximilian Tomaschek, Lowflux recommissioning, 2, Ramon+Tracker, 194.3, , , 30 spills, , 10%, , 10, 1, , , ,
|
Rate |
Sun Jan 10 06:33:22 2021, Maximilian Tomaschek, Lowflux recommissioning, 3, Ramon+Tracker, 175.3, , , 30 spills, , 10%, , 10, 1, , , ,
|
Rate |
Sun Jan 10 06:33:44 2021, Maximilian Tomaschek, Lowflux recommissioning, 5, Ramon+Tracker, 100.4, , , 30 spills, , 10%, , 10, 1, , , ,
|
Rate |
Sun Jan 10 06:38:16 2021, Maximilian Tomaschek, Lowflux recommissioning, 6, Ramon+Tracker, 83, , , 30 spills, , 10%, , 10, 1, , , ,
|
Rate |
Sun Jan 10 06:40:06 2021, Maximilian Tomaschek, Lowflux recommissioning, 7, Ramon+Tracker, 62.4, , , 30 spills, , 10%, , 10, 1, , , ,
|
Rate, up till now looks like the same |
Sun Jan 10 06:42:03 2021, Maximilian Tomaschek, Lowflux recommissioning, 8, Ramon+Tracker, 252.7, , , 30 spills, , , , 10, 1, , 2, ,
|
Rate, factor 10 too high, role ~30kHz instead of 3kHz, Beta nominal |
Sun Jan 10 06:44:59 2021, Maximilian Tomaschek, Lowflux recommissioning, 9, Ramon+Tracker, 62.4, , , 30 spills, , , , 10, 1, , 2, ,
|
Rate, Beta nominal, factor 10 too high |
Sun Jan 10 06:45:55 2021, Maximilian Tomaschek, Lowflux recommissioning, 10, Ramon+Tracker, 252.7, , , 30 spills, , 10%, , 10, 1, , 2, ,
|
Rate, Beta 10% nominal, now 3kHz |
Sun Jan 10 06:46:56 2021, Maximilian Tomaschek, Lowflux recommissioning, 11, Ramon+Tracker, 194.3, , , 30 spills, , 10%, , 10, 1, , 2, ,
|
Rate, Beta 10% nominal |
Sun Jan 10 06:50:45 2021, Maximilian Tomaschek, Lowflux recommissioning, 12, Ramon+Tracker, 175.3, , , 30 spills, , 10%, , 10, 1, , 2, ,
|
Rate |
Sun Jan 10 06:51:12 2021, Maximilian Tomaschek, Lowflux recommissioning, 14, Ramon+Tracker, 100.4, , , 30 spills, , 10%, , 10, 1, , 2, ,
|
Rate, now Beta 10% |
Sun Jan 10 06:51:57 2021, Maximilian Tomaschek, Lowflux recommissioning, 15, Ramon+Tracker, 83, , , 30 spills, , 10%, , 10, 1, , 2, ,
|
Rate, now Beta 10% |
|