ID Date Author Subject Run Number DUT Beam Energy Rate Settingdown Particle Type Events Data Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle
  293   Sun Nov 7 19:07:31 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2121 194.3nominal  Good  10   none 

Start: 11:44
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA. higher energy for Felix Feichtinger
"Accumalte Charge"

coarse run

  294   Sun Nov 7 19:08:47 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2122 194.3nominal  Good  10   none 

Start: 12:00
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA. higher energy for Felix Feichtinger
"Accumalte Charge"

more detailed measurement

  91   Sat Feb 27 18:44:23 2021 Felix Ulrich-PurWaveforms SiC+Si17SiC+Si+RaMon800VII  Good        

Start 11:55
Stopped at 12:05-->acc failure

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

  92   Sat Feb 27 18:49:06 2021 Felix Ulrich-PurWaveforms SiC+Si18SiC+Si+RaMon800VII  Good        

Start 12:39

Neustart der vorherigen Messung

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

  145   Tue Mar 2 16:01:33 2021 Patrick SiebererMPW2 Analog output108MPW2+Picoscope800VIIProton1kGood        

MPW2 ANALOG
Threshold MPW2: 960mV, Pixel R3 C3, Pixel R3 C4, Pixel R0 C1. Pixel R0 C6, danach weiter Pixel bis zum Schichtende
3 Koinzidenz TLU und Hybrid Modus (2er und 3er Koinzidenz) am MPW

1k ADC curves per pixel
 

  168   Tue Mar 16 15:09:33 2021 Patrick SiebererPad Sensoren23 800VIIProton Good      none 

Start: 13:36
Range Shifter Out, Filter 1 IN, Filter 2 IN

  180   Tue Mar 16 15:16:38 2021 Patrick SiebererMPW2 Analog output17MPW2+Picoscope800VIIProton Good        

3er Koinzidenz
Pix 06, 33, 34

  181   Tue Mar 16 15:16:58 2021 Patrick SiebererMPW2 Analog output18MPW2+Picoscope800VIIProton Crap        

2er Koinzidenz
Pix 06, 33, 34
for Beam

  182   Tue Mar 16 15:17:17 2021 Patrick SiebererMPW2 Analog output19MPW2+Picoscope800VIIProton Crap        

3er Koinzidenz
for Beam

  183   Tue Mar 16 15:17:58 2021 Patrick SiebererMPW2 Analog output20MPW2+Picoscope800VIIProton Crap        

3er Koinzidenz
for Beam

  227   Sun Jun 20 19:26:54 2021 Felix Ulrich-PurHADES testrun 800MeV1HADES-LGADs800VIIProton Good      none0

TB 19.6.21

Start 06:00
startet with wrong setting at the beginning (6 instead of 5) rate was then corrected, but RaMon was still running.

Final rate: 100kHz setting
07:24: room request: changed channel on board (was not connected to osci)

  235   Sun Jun 20 19:38:28 2021 Felix Ulrich-PurHADES increased rate run (wrong setting9HADES-LGADs800VIIProton Good  20   none0

TB 19.6.21

Start 19:43
rate setting was not set correctly deg20 in combination with setting VII instead of nominal flux deg10
 

  242   Sun Jun 20 20:00:05 2021 Felix Ulrich-PurHADES testrun 800MeV16HADES-LGADs800VIIProton Good      none0

TB 20.6.21

Start 19:19
Mean rate O(MHz)
 

  275   Sun Nov 7 18:52:29 2021 Felix Ulrich-PurLow flux test 7.11.213 800VII 30 spillsGood      none 

Start: 06:46 O(MHz)

  213   Tue Mar 16 15:37:05 2021 Patrick SiebererSiC strip sensor76SiC+DSSD tracker800VIProton Crap        

Energy Scan
03:02
4Hz, VII -> MHz ?

  273   Sun Nov 7 18:50:31 2021 Felix Ulrich-PurLow flux test 7.11.211 800VI 30 spillsGood      none 

Start: 06:33 O(kHz)

  167   Tue Mar 16 15:09:04 2021 Patrick SiebererPad Sensoren22 800VProton Good      none 

Start: 13:09
Range Shifter Out, Filter 1 IN, Filter 2 IN
Changed compliance values back to 30 uA

  212   Tue Mar 16 15:35:59 2021 Patrick SiebererSiC strip sensor75SiC+DSSD tracker800VProton400kGood        

Energy Scan
02:48
1-6M Hz!

  214   Tue Mar 16 15:37:49 2021 Patrick SiebererSiC strip sensor77SiC+DSSD tracker800VProton6.6MGood        

Energy Scan
03:06-5:18
MHz Rate
Danach: Abbauen

  274   Sun Nov 7 18:52:10 2021 Felix Ulrich-PurLow flux test 7.11.212 800V 30 spillsGood      none 

Start: 06:40 O(100kHz)

ELOG V3.1.5-fc6679b