Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 2 of 18  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Data Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScandown PhantomType PhantomAngle
  19   Sun Jan 10 07:04:21 2021 Maximilian TomaschekLowflux recommissioning21Ramon+Tracker145.4  15 spillsGood  101 0  

Rate, Beta nominal

  20   Sun Jan 10 07:05:52 2021 Maximilian TomaschekLowflux recommissioning23Ramon+Tracker100.4  30 spillsCrap  101 0  

Rate, Beta nominal, suddenly no tracker events

  21   Sun Jan 10 07:14:54 2021 Maximilian TomaschekLowflux recommissioning24Ramon+Tracker83  30 spillsCrap  101 0  

Rate, Beta nominal, no tracker data

  22   Sun Jan 10 07:17:44 2021 Maximilian TomaschekLowflux recommissioning25Ramon+Tracker62.4  30 spillsCrap  101 0  

Rate, Beta nominal, no tracker data

  32   Sun Jan 10 07:24:46 2021 Maximilian TomaschekLowflux recommissioning36Ramon+Tracker252.7  7 spills 1e6 eventsGood  101 0  

Spotsize

  33   Sun Jan 10 07:26:16 2021 Maximilian TomaschekLowflux recommissioning37Ramon+Tracker194.3  7 spills 1e6 eventsGood  101 0  

Spotsize

  34   Sun Jan 10 07:26:31 2021 Maximilian TomaschekLowflux recommissioning38Ramon+Tracker175.3  7 spills 1e6 eventsGood  101 0  

Spotsize

  35   Sun Jan 10 07:26:42 2021 Maximilian TomaschekLowflux recommissioning39Ramon+Tracker145.4  7 spills 1e6 eventsGood  101 0  

Spotsize

  36   Sun Jan 10 07:26:58 2021 Maximilian TomaschekLowflux recommissioning40Ramon+Tracker100.4  7 spills 1e6 eventsGood  101 0  

Spotsize

  37   Sun Jan 10 07:27:37 2021 Maximilian TomaschekLowflux recommissioning45Ramon+Tracker83  7 spills 1e6 eventsGood  101 0  

Spotsize

  38   Sun Jan 10 07:27:55 2021 Maximilian TomaschekLowflux recommissioning47Ramon+Tracker62.4  7 spills 1e6 eventsGood  101 0  

Spotsize, max T 1 & BSY 50 -> rate zu hoch

  46   Sun Jan 10 07:33:19 2021 Maximilian TomaschekLowflux recommissioning55Peakfinder252.7  40 spills 350k eventsGood  101 0  

fail MAPTA Sensor, not trigger, only signal with 5s spill 5s pause (spill over time meas), looked similar

  1   Sun Jan 10 06:27:26 2021 Maximilian TomaschekLowflux recommissioning1Ramon+Tracker252.7  30 spills 10% 101    

Rate,15s spill pause, delay can be set by operator

  2   Sun Jan 10 06:32:13 2021 Maximilian TomaschekLowflux recommissioning2Ramon+Tracker194.3  30 spills 10% 101    

Rate

  3   Sun Jan 10 06:33:22 2021 Maximilian TomaschekLowflux recommissioning3Ramon+Tracker175.3  30 spills 10% 101    

Rate

  4   Sun Jan 10 06:33:44 2021 Maximilian TomaschekLowflux recommissioning5Ramon+Tracker100.4  30 spills 10% 101    

Rate

  5   Sun Jan 10 06:38:16 2021 Maximilian TomaschekLowflux recommissioning6Ramon+Tracker83  30 spills 10% 101    

Rate

  6   Sun Jan 10 06:40:06 2021 Maximilian TomaschekLowflux recommissioning7Ramon+Tracker62.4  30 spills 10% 101    

Rate, up till now looks like the same

  23   Sun Jan 10 07:18:16 2021 Maximilian TomaschekLowflux recommissioning26Ramon+Tracker   30 spillsGood        

Spotsize test, nach power cycle

  24   Sun Jan 10 07:19:03 2021 Maximilian TomaschekLowflux recommissioning27Ramon+Tracker   30 spillsGood        

Spotsize test, nach power cycle

ELOG V3.1.5-fc6679b