Wed Jan 20 17:25:34 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 56, Ramon+Tracker, 800, , , 30 spills, , 10%, 60%, 20, 10, 6dB, , ,
|
MT=1, BSY=50,
1cm off in +x and +y direction
Setting IV |
Wed Jan 20 17:27:58 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 57, Ramon+Tracker, 800, , , 30 spills, , 10%, 60%, 20, 10, 6dB, , ,
|
MT=1, BSY=50,
2cm off in +x and +y direction (wrong direction)
setting IV |
Wed Jan 20 17:28:56 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 58, Ramon+Tracker, 800, , , 30 spills, , 10%, 60%, 20, 10, 6dB, , ,
|
MT=1, BSY=50,
looks +0.5vcm x, -0.5cm y
rate quite low |
Wed Jan 20 17:29:42 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 59, Ramon+Tracker, 800, , , 30 spills, , 10%, 60%, 20, 10, 6dB, , ,
|
MT=1, BSY=50,
x is centered now, y looks 0.25cm off
setting IV |
Wed Jan 20 17:30:17 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 60, Ramon+Tracker, 800, , , 30 spills, , 10%, 60%, 20, 10, 6dB, , ,
|
MT=1, BSY=50,
rate few 100Hz
x looks off, y centered now (after -0.25cm in y correction) |
Wed Jan 20 17:31:04 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 61, Ramon+Tracker, 800, , , 30 spills, Crap, 10%, 60%, 10, 10, 6dB, , ,
|
wrong degrader setting
setting IV
|
Wed Jan 20 17:31:30 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 63, Ramon+Tracker, 800, , , 30 spills, , 10%, 60%, 20, 10, 6dB, , ,
|
MT=1, BSY=50,
beam almost centered (total correction +15mm x (to the left in beam direction) and +7.5 mm y (down in beam direction)
rate between 100Hz and 70 kHz |
Wed Jan 20 17:33:58 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 64, Ramon+Tracker, 800, , , 30 spills, , 10%, 60%, 20, 10, 6dB, , ,
|
MT=1, BSY=50,
beam centered (total correction +12.5mm x (to the left in beam direction) and +7.5 mm y (down in beam direction)
rate between 100Hz and 70 kHz, few 100Hz spills |
Wed Jan 20 17:35:25 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 62, Ramon+Tracker, 800, , , 30 spills, , 10%, 60%, 20, 10, 6dB, , ,
|
MT=1, BSY=50,
now correct degrader, beam still off
setting IV |
Wed Jan 20 17:35:51 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 66, Ramon+Tracker, 800, , , 30 spills, , 10%, 62%, 20, 10, 6dB, , ,
|
MT=1, BSY=50,
beam is centered
rate few 100kHz and two peaks in beam profile |
Wed Jan 20 17:36:21 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 65, Ramon+Tracker, 800, , , 30 spills, , 10%, 80%, 20, 10, 6dB, , ,
|
MT=1, BSY=50,
beam shifted again
jumps in rate too high |
Wed Jan 20 17:41:27 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 67, Ramon+Tracker, 800, , , 30 spills, , 10%, 60.5%, 20, 10, 6dB, , ,
|
MT=1, BSY=50,
beam shifted again
max 30kHz, low rate |
Wed Jan 20 17:42:02 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 68, Ramon+Tracker, 800, , , 30 spills, , 11%, 60%, 20, 10, 6dB, , ,
|
MT=1, BSY=50,
setting IV
|
Wed Jan 20 17:42:31 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 69, Ramon+Tracker, 800, , , 30 spills, , 11%, 60.5%, 20, 10, 6dB, , ,
|
MT=1, BSY=50,
setting IV
|
Wed Jan 20 17:42:38 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 71, Ramon+Tracker, 800, , , 30 spills, , 11%, 60.25%, 20, 10, 6dB, , ,
|
MT=1, BSY=50,
setting IV
|
Wed Jan 20 17:44:19 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 73, Ramon+Tracker, 800, , , 30 spills, , 100%, 60.5%, 20, 10, 6dB, , ,
|
MT=1, BSY=50,
setting V
spot still centered |
Wed Jan 20 17:46:32 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 74, Ramon+Tracker, 800, , , 30 spills, , 11%, 60.5%, 20, 30, 6dB, , ,
|
MT=1, BSY=50,
potential setting VI
few outlier, fewer fluctuations |
Wed Jan 20 17:47:24 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 75, Ramon+Tracker, 800, , , 30 spills, , 12%, 60.5%, 20, 30, 6dB, , ,
|
MT=1, BSY=50,
setting VI
few outlier, fewer fluctuations |
Wed Jan 20 17:47:53 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 76, Ramon+Tracker, 800, , , 30 spills, , 100%, 60.5%, 20, 30, 6dB, , ,
|
MT=1, BSY=50,
beam off
potential setting VII |
Wed Jan 20 17:51:28 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 77, Ramon+Tracker, 800, , , 30 spills, , 100%, 60.5%, 20, 30, 6dB, , ,
|
MT=1, BSY=50,
beam off
potential setting VII |
|