Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025
  MedAustron 2021, Page 18 of 18  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Datadown Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle Text Attachments
  71   Wed Jan 20 17:52:28 2021 Felix Ulrich-PurLowflux p800 commissioning81Ramon+Tracker800  30 spills 100%60.5%20306dB   MT=1, BSY=50,

beam off
potential setting VII
  
  72   Wed Jan 20 17:52:49 2021 Felix Ulrich-PurLowflux p800 commissioning82Ramon+Tracker800  30 spills 100%60.5%20306dB   MT=1, BSY=50,
potential setting VII
new steering +12.5mm x,+10mm y ( -beam
  
  73   Wed Jan 20 17:55:13 2021 Felix Ulrich-PurLowflux p800 commissioning83Ramon+Tracker800  30 spills 100%60.5%20306dB   MT=1, BSY=50,
final setting VII
new steering VII +12.5mm x,+13mm y
  
  74   Wed Jan 20 17:56:06 2021 Felix Ulrich-PurLowflux p800 commissioning84Ramon+Tracker800  30 spills 12%60.5%20306dB   MT=1, BSY=50,
setting VI steering VII,beam is off
again
  
  245   Sat Sep 18 06:20:51 2021 Manuel ChristanellPad Sensoren10 62.4III(EFE+SID2)Proton          01. SiC; 2. Si

Bias 1: 400V; Bias 2: -100 V; SiC
with Cividec
  
  246   Sat Sep 18 07:22:07 2021 Manuel ChristanellPad Sensoren11SiC+Si62.4III(EFE+SID2)Proton          01. SiC; 2. Si

Small SiC Signal;
Cividec for SiC
  
  302   Sun Nov 21 13:51:53 2021 Simon WaidComparison SiC, Si, Si LGAD and Diamond1SiC+Si62.4I(EFE+SID0)Proton10000         Bias voltage SiC: 800

Bias voltage Si: -150

From a beam perspective the Si
  
  303   Sun Nov 21 13:55:05 2021 Simon WaidComparison SiC, Si, Si LGAD and Diamond2SiC+Si62.4I(EFE+SID0)Proton1000000         Bias voltage SiC: 800

Bias voltage Si: -150

From a beam perspective the Si
  
  304   Sun Nov 21 14:05:18 2021 Simon WaidComparison SiC, Si, Si LGAD and Diamond3 62.4I(EFE+SID0)Proton10000         Bias voltage SiC: 800

Bias voltage Si LGAD: -100

From a beam perspective the SiC
  
  305   Sun Nov 21 14:53:00 2021 Simon WaidComparison SiC, Si, Si LGAD and Diamond4Diamond+LGAD62.4I(EFE+SID0)Proton100000         Bias voltage Diamond: 500

Bias voltage Si LGAD: -100

From a beam perspective the Diamond
  
  311   Sat Oct 8 07:10:31 2022 Christian IrmlerRD50-MPW3 - First Testbeam               Tracker xml file: hvcmos_mpw3_20221008_TLU_00-000053.xml

 
 hvcmos_mpw3_20221008_TLU_00-000053.xml 
ELOG V3.1.5-fc6679b