Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 18 of 18  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Authordown Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Data Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle
  326   Sat Oct 8 10:21:20 2022 Christian Irmlerramon + tracker + DUT16RD50-MPW3252.7   Goodlowflux low       

ASIC: TH 1800 - too high, no noise hits
BEAM OFF, for TH check

  327   Sat Oct 8 10:24:12 2022 Christian Irmlerramon + tracker + DUT17RD50-MPW3252.7   Goodlowflux low       

ASIC: TH 1600 - too high
BEAM OFF, for TH check

  328   Sat Oct 8 10:29:27 2022 Christian Irmlerramon + tracker + DUT18RD50-MPW3252.7   Goodlowflux low       

ASIC: TH 1400
BEAM OFF, for TH check

  329   Sat Oct 8 10:30:38 2022 Christian Irmlerramon + tracker + DUT19RD50-MPW3252.7   Goodlowflux low       

ASIC: TH 1300 again for verificationn - still too many noise hits
BEAM OFF, for TH check

  330   Sat Oct 8 10:32:44 2022 Christian Irmlerramon + tracker + DUT20RD50-MPW3252.7   Craplowflux low       

ASIC: TH 1350
BEAM OFF, for TH check

MPW3 monitor not connected --> invalid

  331   Sat Oct 8 10:35:23 2022 Christian Irmlerramon + tracker + DUT21RD50-MPW3252.7   Craplowflux low       

ASIC: TH 1350
BEAM OFF, for TH check

no noise hits

 

  332   Sat Oct 8 10:37:45 2022 Christian Irmlerramon + tracker + DUT22RD50-MPW3252.7   Unknownlowflux low       

ASIC: TH 1330
BEAM OFF, for TH check

only few (1 or 2) pixel fire at a low frequency.

Will use this threshold from now on.

 

 

  333   Sat Oct 8 10:40:04 2022 Christian Irmlerramon + tracker + DUT23RD50-MPW3252.7   Unknownlowflux low       

ASIC: TH 1330
BEAM ON all included

 

 

 

  334   Sat Oct 8 10:56:01 2022 Christian Irmlerramon + tracker + DUT24RD50-MPW3100.4   Unknownlowflux low       

ASIC: TH 1330
BEAM ON all included

 

 

 

 

  335   Sat Oct 8 10:58:00 2022 Christian Irmlerramon + tracker + DUT25RD50-MPW3100.4   Unknownlowflux low       

ASIC: TH 1310 seems to be okay
BEAM ON all included

2 GUIs started -> New Run

 

 

 

 

  338   Sat Oct 8 11:12:32 2022 Christian Irmlerramon + tracker + DUT28RD50-MPW3100.4   Unknownlowflux high       

ASIC: TH 1310
BEAM OFF

 

 

 

 

ELOG V3.1.5-fc6679b