Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 18 of 18  Not logged in ELOG logo
Entry  Sat Oct 8 09:19:01 2022, Patrick Sieberer, ramon + tracker + DUT, 10, RD50-MPW3, 252.7, , , , Good, lowflux high, , , , , , ,  run9_hitmap_tracker.png

repeat run 9

max_trgs: 100

tracker still not working.

Entry  Sun Jan 10 06:27:26 2021, Maximilian Tomaschek, Lowflux recommissioning, 1, Ramon+Tracker, 252.7, , , 30 spills, , 10%, , 10, 1, , , ,  

Rate,15s spill pause, delay can be set by operator

Entry  Sat Feb 27 09:26:27 2021, Felix Ulrich-Pur, Rate verification, 1, SiC+Si+RaMon, 62.4, III(EFE+SID2), , , Unknown, , , , , , , ,  

Start 06:37
rate looks okish. few emtpy spills

 

2021-02-27, 06:07:

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.112V channel 1, 0-Level: 2.315V channel 1

position:

x: 0
y: 0 

2021-02-27, 06:30:

Referenz: 2.477V channel 1
channel 2 unverändert
 

2021-02-27, 06:37:

Setting: 3 

Run 1: 6:37 62.4 MeV, Rate geringer als erwartet 

 

Entry  Tue Mar 16 14:51:53 2021, Patrick Sieberer, Pad Sensoren, 1, , 62.4, III(EFE+SID2), Proton, , Unknown, , , , , , , none,  

Start: 06:38
Range Shifter Out, Filter 1 IN, Filter 2 IN
Scintillators in front

Entry  Wed May 12 08:46:41 2021, Felix Ulrich-Pur, Alignment Run, 1, DSSD-Tracker, 252.7, II(BETA+EFE), Proton, , Good, , , , , , , none,  

TB 24.4.21
Alignment run

Entry  Sun Jun 20 19:26:54 2021, Felix Ulrich-Pur, HADES testrun 800MeV, 1, HADES-LGADs, 800, VII, Proton, , Good, , , , , , , none, 0 

TB 19.6.21

Start 06:00
startet with wrong setting at the beginning (6 instead of 5) rate was then corrected, but RaMon was still running.

Final rate: 100kHz setting
07:24: room request: changed channel on board (was not connected to osci)

Entry  Sun Nov 7 18:50:31 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 1, , 800, VI, , 30 spills, Good, , , , , , , none,  

Start: 06:33 O(kHz)

Entry  Sun Nov 21 13:51:53 2021, Simon Waid, Comparison SiC, Si, Si LGAD and Diamond, 1, SiC+Si, 62.4, I(EFE+SID0), Proton, 10000, , , , , , , , ,  

Bias voltage SiC: 800

Bias voltage Si: -150

From a beam perspective the Si detector was the first target, on oscilloscope  channel 1, SiC was the second target connected to oscilloscope channel 3.

Triggering source was the SiC detector.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

Entry  Sat Dec 11 17:46:17 2021, Felix Ulrich-Pur, Alignment run, 1, DSSD-Tracker, 800, V, Proton, , Good, , , , , , , none,  

Fluence loss measurement 11.12.2021

Start 14:45

 

Entry  Sat Oct 8 07:11:03 2022, Christian Irmler, Ramon only, 1, RD50-MPW3, 800, , Proton, , Crap, lowflux high, , , , , , ,  
 
Entry  Sat Oct 8 07:10:31 2022, Christian Irmler, RD50-MPW3 - First Testbeam, , , , , , , , , , , , , , ,  hvcmos_mpw3_20221008_TLU_00-000053.xml

Tracker xml file: hvcmos_mpw3_20221008_TLU_00-000053.xml

 

ELOG V3.1.5-fc6679b